Electrical, Thermal, and Mechanical Characterization of Silicon Microcantilever Heaters
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Silicon atomic force microscope (AFM) cantilevers having integrated solid-state heaters were originally developed for application to data storage, but have since been applied to metrology, thermophysical property measurements, and nanoscale manufacturing. These applications beyond data storage have strict requirements for mechanical characterization and precise temperature calibration of the cantilever. This paper describes detailed mechanical, electrical, and thermal characterization and calibration of AFM cantilevers having integrated solid-state heaters. Analysis of the cantilever response to electrical excitation in both time and frequency domains aids in resolving heat transfer mechanisms in the cantilever. Raman spectroscopy provides local temperature measurement along the cantilever with resolution near 1 mum and 5degC and also provides local surface stress measurements. Observation of the cantilever mechanical thermal noise spectrum at room temperature and while heated provides insight into cantilever mechanical behavior and compares well with finite-element analysis. The characterization and calibration methodology reported here expands the use of heated AFM cantilevers, particularly the uses for nanomanufacturing and sensing
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194 · cited 1×
“equipartition theorem and relates thermal energy to the elastic potential energy of the cantilever [46].”
Micro-Raman spectroscopy to study local mechanical stress in silicon integrated circuits
Wolf, I. D. (1996) · Semiconductor Science and Technology · doi:10.1088/0268-1242/11/2/001 · Cited by 983 · cited 1×
“stress tensor for any silicon material [42]–[44].”
The "millipede" - nanotechnology entering data storage
Vettiger, P., Cross, G., Despont, M., Drechsler, U., Durig, U., Gotsmann, B., Haberle, W., Lantz, M. A., Rothuizen, H. E., Stutz, R., et al. (2002) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2002.1005425 · Cited by 739 · cited 2×
“ficiently long time to deform the polymer and to form nanoscale data bit indents [3], [5].”
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Scanning Force Microscopy: With Applications to Electric, Magnetic and Atomic Forces
Sarid, D. (1994) · doi:10.1093/oso/9780195092042.001.0001 · Cited by 575
Crystal size and temperature measurements in nanostructured silicon using Raman spectroscopy
Viera, G., Huet, S., & Boufendi, L. (2001) · Journal of Applied Physics · doi:10.1063/1.1398601 · Cited by 268 · cited 1×
“spatial resolution in diamond structures [32], silicon [33]–[35], III–V semiconductors [36]–[39], and polysilicon MEMS [40].”
A microsensor for trinitrotoluene vapour
Pinnaduwage, L. A., Gehl, A., Hedden, D. L., Muralidharan, G., Thundat, T., Lareau, R. T., Sulchek, T., Manning, L., Rogers, B., Jones, M., et al. (2003) · Nature · doi:10.1038/425474a · Cited by 189
Kuball, M., Rajasingam, S., Sarua, A., Uren, M. J., Martin, T., Hughes, B. T., Hilton, K. P., & Balmer, R. S. (2003) · Applied Physics Letters · doi:10.1063/1.1534935 · Cited by 182
Atomic force microscope cantilevers for combined thermomechanical data writing and reading
King, W. P., Kenny, T. W., Goodson, K. E., Cross, G., Despont, M., Dürig, U., Rothuizen, H., Binnig, G. K., & Vettiger, P. (2001) · Applied Physics Letters · doi:10.1063/1.1351846 · Cited by 173 · cited 1×
“With the cantilever dimensions and temperature-dependent resistivities, the cantilever electrical resistance depends on the cantilever temperature solely in the heater region to within 10% [9], [28]–[30].”
Self-citationChui, B. W., Stowe, T. D., Ju, Y. S., Goodson, K. E., Kenny, T. W., Mamin, H. J., Terris, B. D., Ried, R. P., & Rugar, D. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.661386 · Cited by 172
Measurement of porous silicon thermal conductivity by micro-Raman scattering
Périchon, S., Lysenko, V., Remaki, B., Barbier, D., & Champagnon, B. (1999) · Journal of Applied Physics · doi:10.1063/1.371424 · Cited by 171 · cited 1×
“spatial resolution in diamond structures [32], silicon [33]–[35], III–V semiconductors [36]–[39], and polysilicon MEMS [40].”
Mapping of local temperatures on mirrors of GaAs/AlGaAs laser diodes
Brugger, H., & Epperlein, P. W. (1990) · Applied Physics Letters · doi:10.1063/1.102611 · Cited by 120 · cited 1×
“spatial resolution in diamond structures [32], silicon [33]–[35], III–V semiconductors [36]–[39], and polysilicon MEMS [40].”
Micromechanical thermogravimetry
Berger, R., Lang, H. P., Gerber, C., Gimzewski, J. K., Fabian, J.-H., Scandella, L., Meyer, E., & Güntherodt, H. ‐. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00817-3 · Cited by 110
Detection of trinitrotoluene via deflagration on a microcantilever
Pinnaduwage, L. A., Wig, A., Hedden, D. L., Gehl, A. C., Yi, D., Thundat, T. G., & Lareau, R. T. (2004) · Journal of Applied Physics · doi:10.1063/1.1697619 · Cited by 100 · cited 1×
“[20]–[22], thermomechanical bending in the cantilever should be well understood.”
Thermally Activated Nanowear Modes of a Polymer Surface Induced by a Heated Tip
Gotsmann, B., & Dürig, U. T. (2004) · Langmuir · doi:10.1021/la036112w · Cited by 80 · cited 1×
“turing [11], [13], metrology [14], [15], and thermophysical property measurements [16], [17] all demand temperature calibration and mechanical characterization beyond what has been previously reported.”
Thermal conduction from microcantilever heaters in partial vacuum
Lee, J., Wright, T. L., Abel, M. R., Sunden, E. O., Marchenkov, A. N., Graham, S. L., & King, W. P. (2007) · Journal of Applied Physics · doi:10.1063/1.2403862 · Cited by 80 · cited 1×
“studied to determine safe operating powers to prevent thermal damage [41].”
Self-citationCombining high resolution and tensorial analysis in Raman stress measurements of silicon
Bonera, E., Fanciulli, M., & Batchelder, D. N. (2003) · Journal of Applied Physics · doi:10.1063/1.1592872 · Cited by 76 · cited 1×
“, uniaxial, biaxial, hydrostatic) to quantitatively determine stress in silicon [45].”
INTRINSIC-CARRIER THERMAL RUNAWAY IN SILICON MICROCANTILEVERS
B. W. Chui, M. A. (1999) · Microscale Thermophysical Engineering · doi:10.1080/108939599199765 · Cited by 71 · cited 1×
“intrinsic carrier-based “thermal runaway” characteristics [18].”
Temperature distribution in Si-MOSFETs studied by micro-Raman spectroscopy
Ostermeir, R., Brunner, K. H., Abstreiter, G., & Weber, W. M. (1992) · IEEE Transactions on Electron Devices · doi:10.1109/16.127476 · Cited by 65
Frequency-Dependent Electrical and Thermal Response of Heated Atomic Force Microscope Cantilevers
Park, K., Lee, J., Zhang, Z. M., & King, W. P. (2007) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.889498 · Cited by 60 · cited 1×
“separate paper [31].”
Self-citationThermal Metrology of Silicon Microstructures Using Raman Spectroscopy
Abel, M. R., Wright, T. L., King, W. P., & Graham, S. L. (2007) · IEEE Transactions on Components and Packaging Technologies · doi:10.1109/tcapt.2007.897993 · Cited by 52 · cited 1×
“troscopy has also shown some distinct advantages over other techniques such as infrared microscopy and thermoreflectance, since it can measure both temperature and stress simultaneously in silicon-based MEMS devices [23]–[25].”
Self-citationSpatially Resolved Temperature Mapping of Electrothermal Actuators by Surface Raman Scattering
Kearney, S. P., Phinney, L. M., & Baker, M. S. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.872233 · Cited by 47 · cited 1×
“troscopy has also shown some distinct advantages over other techniques such as infrared microscopy and thermoreflectance, since it can measure both temperature and stress simultaneously in silicon-based MEMS devices [23]–[25].”
Masters, N. D., Ye, W., & King, W. P. (2005) · Physics of Fluids · doi:10.1063/1.1932313 · Cited by 40
Self-citationRaman spectroscopy for a micrometric and tensorial analysis of stress in silicon
Bonera, E., Fanciulli, M., & Batchelder, D. N. (2002) · Applied Physics Letters · doi:10.1063/1.1519105 · Cited by 34
Thermal Metrology of Polysilicon MEMS using Raman Spectroscopy
Abel, M. R. (2005) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 7
Cited by
Siemens, M. E., Li, Q., Yang, R., Nelson, K. A., Anderson, E. H., Murnane, M. M., & Kapteyn, H. C. (2010) · Nature Materials · doi:10.1038/nmat2568 · Cited by 443
Metadata
- Authors
- Lee, J., Beechem, T., Wright, T. L., Nelson, B. A., Graham, S., & King, W. P.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2006-12
- Volume
- 15
- Issue
- 6
- Pages
- 1644-1655
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2143198442
- Cited by
- 209
- References
- 26
- FWCI
- 25.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.