Parylene-Based Cuff Electrode With Integrated Microfluidics for Peripheral Nerve Recording, Stimulation, and Drug Delivery
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A novel Parylene C-based peripheral nerve interface that combines both electrodes and microfluidic channels in an adjustable cuff was designed, fabricated, and characterized. This minimally invasive interface incorporates a drug delivery system for targeted delivery of lysing agents and neurotrophic factors to the nerve surface to locally disrupt the epineurium and allow fascicular selectivity. Multiple platinum (Pt) electrodes were embedded in the microfluidic channels for neural stimulation and recording. The lyse-and-attract cuff electrode (LACE) uses a simple locking mechanism that is adjustable for close contact with nerves of varying diameters. Devices were fabricated using standard Parylene microfabrication techniques resulting in low variability and high device yield. A procedure for the implantation of the LACE was developed and successfully demonstrated in vivo around rat sciatic nerves. The adjustable locking mechanism demonstrated adequate holding strength and fit around the nerves. Benchtop electrochemical characterization of the thin-film Pt electrodes showed that the electrodes possessed high charge storage capacity (>1 mC/cm2) and low impedances ($< 2~\text{k}\Omega $at 1 kHz) suitable for neural stimulation and recording. As expected, embedded electrodes demonstrated higher impedance values. Acute neural recording from the rat sciatic nerve verified the capability of the LACE to record evoked neural activity (compound action potentials). Controlled and localized microfluidic infusions were achieved at low flow rates ($< 1~\mu \text{L}$/min). Finally, infusion experiments in vivo demonstrated targeted drug delivery to the sciatic nerve fascicles. This multifunctional peripheral nerve interface has the potential to enhance implant-tissue integration in vivo and provide reliable chronic performance not available in the existing extraneural or intraneural interfaces. [2018-0192]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“Interfacing the peripheral nervous system (PNS) allows other forms of sensory feedback besides visual, such as tactile and proprioceptive sensation which are necessary to provide realistic and fine motor control [6], [7].”
BackgroundNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 4×
“The LACE adjustable interlocking mechanism allowed for a secured and tight fit around the sciatic nerve while minimizing mechanical damage to the delicate nerve tissue commonly seem in cuff interfaces surgically secured by suturing to the epineurium [4],”
BackgroundMethodInfluentialA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 1×
“Due to the low-risk of tissue damage or irritation, extraneural designs are favored for long-term (chronic, 2-11 years) applications [17], [18], but the limitations in signal fidelity and nerve selectivity preclude fine motor control required for prostheses.”
BackgroundA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 1×
“Transverse interfaces, such as the transverse intrafascicular multichannel electrode (TIME), can achieve single unit recordings from several nerve fibers in multiple fascicles, and can stimulate with low current requirements and high spatial selectivity [25], [26].”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 2×
“Common design features include self-sizing and locking mechanisms, which allow snug placement of electrodes on the surface of nerves of varying diameters [12], [14], [16].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 2×
“Improved access to individual fascicles has been achieved by extraneural interfaces which reshape the nerve, (i.e. flattening) as demonstrated by Tyler and Durand [19].”
MethodDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“reduce soft-tissue damage and foreign body reaction [11].”
BackgroundCriteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 1×
“Pt was selected as the electrode material due to high resistance to corrosion in in vivo environments, low decomposition characteristics during stimulation, and high charge injection limit [56]–[58].”
Method
Cited by
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Self-citationInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“A common method for drug delivery in flexible chemical PNIs consists in fabricating microfluidic channels on cuff electrodes [173, 178, 186] which can then be connected to external syringe pumps [186] to provide pharmacological treatment over time.”
BackgroundMethodInfluentialSong, H., Kim, M., Kim, E., Lee, J., Jeong, I., Lim, K., Ryu, S. Y., Oh, M., Kim, Y., & Park, J. (2024) · BMEMat · doi:10.1002/bmm2.12048 · Cited by 61
Metadata
- Authors
- Cobo, A. M., Larson, C. E., Scholten, K., Miranda, J. A., Elyahoodayan, S., Song, D., Pikov, V., & Meng, E.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2019-02
- Volume
- 28
- Issue
- 1
- Pages
- 36-49
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2905504670
- Cited by
- 43
- References
- 23
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parylene-Based Cuff Electrode With Integrated Microfluidics for Peripheral Nerve Recording, Stimulation, and Drug Delivery. https://app.cochat.ai/papers/10.1109/jmems.2018.2881908
- The paper
- Cobo, A. M., Larson, C. E., Scholten, K., Miranda, J. A., Elyahoodayan, S., Song, D., Pikov, V., & Meng, E. (2019). Parylene-Based Cuff Electrode With Integrated Microfluidics for Peripheral Nerve Recording, Stimulation, and Drug Delivery. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2018.2881908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.