Abstract
Diabetes mellitus claims millions of lives every year. It affects the body in various ways by leading to many serious illnesses and premature mortality. Heart and kidney diseases, which are caused by diabetes, are increasing at an alarming rate. In this paper, we report a study of a noninvasive measurement technique to determine the glucose levels in the human body. Current existing methods to quantify the glucose level in the blood are predominantly invasive that involve taking the blood samples using finger pricking. In this paper, we report a spectroscopy-based noninvasive glucose monitoring system to measure glucose concentration. Near-infrared transmission spectroscopy is used and in vitro experiments are conducted, as well as in vivo. Our experimental study confirms a correlation between the sensor output voltage and glucose concentration levels. We report a low-cost prototype of spectroscopy-based noninvasive glucose monitoring system that demonstrates promising results in vitro and establishes a relationship between the optical signals and the changing levels of blood-glucose concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · cited 1×
“As reported by [41] the absorption spectra of major intracellular absorbers where the molecular exctinction coefficients of oxygenated haemoglobin and melanin and the absorption coefficient of water are represented in (see 41, ref.”
BackgroundNon-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires
Yao, S., & Zhu, Y. (2014) · Nanoscale · doi:10.1039/c3nr05496a · Cited by 1,028
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390 · cited 2×
“Therefore, the above stated non-invasive glucose sensors [28]–[32] are very complex to use and would not be available for an affordable price.”
BackgroundMethod
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
A Noninvasive Glucose Monitoring SoC Based on Single Wavelength Photoplethysmography
Hina, A., & Saadeh, W. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2979514 · Cited by 99
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Metadata
- Authors
- Haxha, S., & Jhoja, J.
- Venue
- IEEE Photonics Journal
- Published
- 2016-12
- Volume
- 8
- Issue
- 6
- Pages
- 1-11
- ISSN
- 1943-0647 (ISSN-L)
- 1943-0655
- OpenAlex
- W2561576762
- Cited by
- 152
- References
- 4
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Based Noninvasive Glucose Monitoring Sensor Prototype. https://app.cochat.ai/papers/10.1109/jphot.2016.2616491
- The paper
- Haxha, S., & Jhoja, J. (2016). Optical Based Noninvasive Glucose Monitoring Sensor Prototype. IEEE Photonics Journal. https://doi.org/10.1109/jphot.2016.2616491
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.