The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Medical image registration using mutual information
Abstract
Analysis of multispectral or multitemporal images requires proper geometric alignment of the images to compare corresponding regions in each image volume. Retrospective three-dimensional alignment or registration of multimodal medical images based on features intrinsic to the image data itself is complicated by their different photometric properties, by the complexity of the anatomical objects in the scene and by the large variety of clinical applications in which registration is involved. While the accuracy of registration approaches based on matching of anatomical landmarks or object surfaces suffers from segmentation errors, voxel-based approaches consider all voxels in the image without the need for segmentation. The recent introduction of the criterion of maximization of mutual information, a basic concept from information theory, has proven to be a breakthrough in the field. While solutions for intrapatient affine registration based on this concept are already commercially available, current research in the field focuses on interpatient nonrigid matching.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 36,808
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationA survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Nonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Multiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Self-citationPattern Classification and Scene Analysis.
Grenander, U., Duda, R. O., & Hart, P. E. (1974) · Journal of the American Statistical Association · doi:10.2307/2286028 · Cited by 1,006
Multimodal Image Coregistration and Partitioning—A Unified Framework
Ashburner, J., & Friston, K. (1997) · NeuroImage · doi:10.1006/nimg.1997.0290 · Cited by 927
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationA comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Image registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
Automated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Self-citationRegistration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Theory of statistical inference and information
Vajda, I. (1989) · Medical Entomology and Zoology · Cited by 463
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Textbook of Stereotactic and Functional Neurosurgery
(2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6 · Cited by 457
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Maes, F., Vandermeulen, D., & Suetens, P. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80030-9 · Cited by 397
Self-citationFast Fluid Registration of medical images
Bro-Nielsen, M., & Gramkow, C. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046964 · Cited by 395
Variational Methods for Multimodal Image Matching
Hermosillo, G., Chefd'Hotel, C., & Faugeras, O. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020830525823 · Cited by 388
Automated 3-D registration of MR and CT images of the head
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80011-9 · Cited by 374
Schnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Pietrzyk, U., Herholz, K., Fink, G. R., Jacobs, A., Mielke, R., Slansky, I., Würker, M., & Heiss, W. (1994) · PubMed · Cited by 318
A viscous fluid model for multimodal non-rigid image registration using mutual information
D'Agostino, E., Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00039-2 · Cited by 277
Self-citationVoxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationInterpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Self-citationANIMAL+INSECT: Improved Cortical Structure Segmentation
Collins, D. L., Zijdenbos, A. P., Baaré, W. F. C., & Evans, A. C. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_16 · Cited by 253
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Debois, M., Oyen, R., Maes, F., Verswijvel, G., Gatti, G., Bosmans, H., Feron, M., Bellon, E., Kutcher, G., Van Poppel, H., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00288-6 · Cited by 212
Self-citationA hierarchical approach to elastic registration based on mutual information
Likar, B., & Pernuš, F. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00053-6 · Cited by 209
Non-rigid matching using demons
Thirion, J.-P. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517081 · Cited by 197
Evaluation of ridge seeking operators for multimodality medical image matching
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.491617 · Cited by 189
A review of medical image registration
Ma, B. (1999) · Information of Medical Equipment · Cited by 173
Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
Studholme, C., Constable, R. T., & Duncan, J. S. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896788 · Cited by 167
Non-rigid registration using higher-order mutual information:
Rueckert, D., Clarkson, M. J., Hill, D. L. G., & Hawkes, D. J. (2000) · SPIE Proceedings · doi:10.1117/12.804801 · Cited by 165
Vansteenkiste, J. F., Stroobants, S. G., Dupont, P. J., De Leyn, P. R., De Wever, W. F., Verbeken, E. K., Nuyts, J. L., Maes, F. P., & Bogaert, J. G. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050327 · Cited by 164
Self-citationNew approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Automatic Construction of 3D Statistical Deformation Models Using Non-rigid Registration
Rueckert, D., Frangi, A. F., & Schnabel, J. A. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_10 · Cited by 155
Three-dimensional alignment of functional and morphological tomograms.
Pietrzyk, U., Herholz, K., & Wd, H. (1990) · PubMed · Cited by 153
Voxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Mutual information matching in multiresolution contexts
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00054-8 · Cited by 142
Automatic registration of CT and MR brain images using correlation of geometrical features
van den Elsen, P. A., Maintz, J. B. A., Pol, E.-J. D., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387719 · Cited by 142
$f$ -Information Measures in Medical Image Registration
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.836872 · Cited by 135
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., & Maciunas, R. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.759119 · Cited by 133
Non-rigid multimodal image registration using mutual information
Gaens, T., Maes, F., Vandermeulen, D., & Suetens, P. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056299 · Cited by 123
Self-citationMapping eddy current induced fields for the correction of diffusion-weighted echo planar images
Horsfield, M. A. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00077-6 · Cited by 117
3D Multi-Modality Medical Image Registration Using Feature Space Clustering
Collignon, A. M. F., Vandermeulen, D., Suetens, P., & Marchal, G. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_22 · Cited by 113
Self-citationA new class of similarity measures for robust image registration
Alain Venot, A., Lebruchec, J.-F., & Roucayrol, J. C. (1984) · Computer Vision Graphics and Image Processing · doi:10.1016/s0734-189x(84)80020-1 · Cited by 112
Genetic algorithms for a robust 3-D MR-CT registration
Rouet, J.-M., Jacq, J.-J., & Roux, C. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.845205 · Cited by 112
Gee, J. C., & Bajcsy, R. (1999) · Elsevier eBooks · doi:10.1016/b978-012692535-7/50087-2 · Cited by 108
Hecke, W. V., Leemans, A., D’Agostino, E., Backer, S. D., Vandervliet, E. J. M., Parizel, P. M., & Sijbers, J. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.906786 · Cited by 107
Technical Note. Effect of Geometrical Distortion Correction in MR on Image Registration Accuracy
Maurer, C. R., Aboutanos, G. B., Dawant, B. M., et al. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199607000-00032 · Cited by 104
Comparison of edge-based and ridge-based registration of CT and MR brain images
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80010-7 · Cited by 97
Volume image registration by template matching
Ding, L., Ardeshir Goshtasby, A., & Satter, M. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00101-3 · Cited by 96
General multimodal elastic registration based on mutual information
Maintz, J. B. A., Meijering, E. H. W., & Viergever, M. A. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.310845 · Cited by 94
On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery
Michiels, J. J., Bosmans, H., Pelgrims, P., Vandermeulen, D., Gybels, J., Marchal, G., & Suetens, P. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92200-4 · Cited by 85
Self-citationPietrzyk, U., Herholz, K., Schuster, A. K.-G., von Stockhausen, H.-M., Lucht, H., & Heiss, W. (1996) · European Journal of Radiology · doi:10.1016/0720-048x(95)00713-z · Cited by 85
Incorporating connected region labelling into automated image registration using mutual information
Studholme, C., Hill, D., & Hawkes, D. J. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534054 · Cited by 84
Affine Registration with Feature Space Mutual Information
Butz, T., & Thiran, J. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_66 · Cited by 82
Hill, D., Hawkes, D. J., Harrison, N. A., & Ruff, C. (2005) · Springer eBooks · doi:10.1007/bfb0013788 · Cited by 73
Grey value correlation techniques used for automatic matching of CT and MR brain and spine images
van den Elsen, P. A., Pol, E.-J. D., Sumanaweera, T. S., Hemler, P. F., Napel, S. A., & Adler, J. R. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185182 · Cited by 73
Textbook of Stereotactic and Functional Neurosurgery
Welch, W. C. (1998) · JAMA · doi:10.1001/jama.279.15.1225 · Cited by 68
Wollny, G., & Kruggel, F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803113 · Cited by 66
Measures of 3D medical image alignment
Studholme, C. (1997) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 62
Mutual information based registration of medical images
Pluim, J. P. W. (2001) · TU/e Research Portal · doi:10.6100/ir783142 · Cited by 61
Constructing Patient Specific Models for Correcting Intraoperative Brain Deformation
Castellano-Smith, A. D., Hartkens, T., Schnabel, J. A., Hose, D. R., Liu, H., Hall, W. A., Truwit, C. L., Hawkes, D. J., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_130 · Cited by 60
Studholme, C., Cardenas, V. A., Schuff, N. W., Rosen, H. J., Miller, B. L., & Weiner, M. W. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_6 · Cited by 58
Multimodality deformable registration of pre- and intraoperative images for MRI-guided brain surgery
Hata, N., Dohi, T., Warfield, S. K., Wells, W. M., Kikinis, R., & Jolesz, F. A. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056296 · Cited by 56
Kjems, U., Strother, S. C., Anderson, J., Law, I. G., & Hansen, L. K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.768840 · Cited by 56
Elastic registration of fMRI data using Bezier-spline transformations
Otte, M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.918470 · Cited by 56
Zhu, Y., & Cochoff, S. M. (2002) · PubMed · Cited by 56
Image registration of multimodality 3-D medical images by chamfer matching
Jiang, H., Tainter, K. S. H., & Robb, R. A. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.59565 · Cited by 54
Improved efficiency for MRI-SPET registration based on mutual information
Thurfjell, L., Lau, Y. H., Andersson, J., & Hutton, B. F. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000270 · Cited by 49
Automated 3D Registration of Truncated MR and CT Images of the Head.
Studholme, C., Hill, D., & Hawkes, D. J. (1995) · British Machine Vision Conference (BMVC) · doi:10.5244/c.9.3 · Cited by 45
Quantitative and clinical analysis of SPECT image registration for epilepsy studies.
Brinkmann, B. H., O'Brien, T. J., Aharon, S., O'Connor, M. K., Mullan, B. P., Hanson, D. P., & Robb, R. A. (1999) · PubMed · Cited by 43
Image registration: Convex weighting functions for histogram-based similarity measures
Buzug, T. M., Weese, J., Fassnacht, C., & Cristian Lorenz, A. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029239 · Cited by 41
Pseudocorrelation: A fast, robust, absolute, grey‐level image alignment algorithm
Radcliffe, T. J., Rajapakshe, R., & Shalev, S. (1994) · Medical Physics · doi:10.1118/1.597336 · Cited by 39
Lau, Y. H., Braun, M., & Hutton, B. F. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/326 · Cited by 37
Comparison of Feature-Based Matching of CT and MR Brain Images
Maintz, J. B. A., van den Elsen, P. A., & Viergever, M. A. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_25 · Cited by 36
Weighted and deterministic entropy measure for image registration using mutual information
Rodriguez-Carranza, C. E., & Loew, M. H. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.310854 · Cited by 35
Retrospective registration of tomographic brain images
Maintz, J. B. A. (1996) · Utrecht University Repository (Utrecht University) · Cited by 31
Registration of multimodality medical images using a region overlap criterion
Chiron, P. G., & Bizais, Y. (1992) · CVGIP Graphical Models and Image Processing · doi:10.1016/1049-9652(92)90024-r · Cited by 27
Coincident bit counting-a new criterion for image registration
Chiang, J. Y., & Sullivan, B. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.222663 · Cited by 23
Improving registration of 3-D medical images using a mechanical based method
Malandain, G., Fernández-Vidal, S., & Rocchisani, J.-M. (1994) · Lecture notes in computer science · doi:10.1007/bfb0028342 · Cited by 16
Research works printed but not linked: 36
- hemler, 1995, a quantitative comparison of residual error for three different multimodality registration techniques, Proc 14th Int Conf Information Processing in Medical Imaging (IPMI 95), 3, 251
- 10.1002/(SICI)1522-712X(1995)1:1<35::AID-IGS6>3.3.CO;2-D · doi:10.1002/(sici)1522-712x(1995)1:1<35::aid-igs6>3.3.co;2-d
- hellier, 2000, multimodal nonrigid warping for correction of distortions in functional mri, Proc Medical Image Computing and Computer-Assisted Intervention (MICCAI 00), 1935, 512, 10.1007/978-3-540-40899-4_52 · doi:10.1007/978-3-540-40899-4_52
- 10.1109/42.811267 · doi:10.1109/42.811267
- friston, 1996, “ SPM short course”
- 10.1109/42.736049 · doi:10.1109/42.736049
- fitzpatrick, 1994, Retrospective Image Registration Evaluation National Institutes of Health
- 10.1016/S1053-8119(96)80160-1 · doi:10.1016/s1053-8119(96)80160-1
- maes, 1998, Segmentation and registration of multimodal images from theory implementation and validation to a useful tool in clinical practice
- 10.1006/cviu.1999.0812 · doi:10.1006/cviu.1999.0812
- 10.1002/(SICI)1097-0320(19991001)37:2<93::AID-CYTO2>3.3.CO;2-R · doi:10.1002/(sici)1097-0320(19991001)37:2<93::aid-cyto2>3.3.co;2-r
- 10.1117/12.174032 · doi:10.1117/12.174032
- bro-nielsen, 1997, rigid registration of ct, mr and cryosection images using a glcm framework, Proc 1st Joint Conf Computer Vision Virtual Reality and Robotics in Medicine and Medical Robotics and Computer-Assisted Surgery (CVRMED-MRCAS 97), 1205, 171
- 10.1016/S0262-8856(00)00058-5 · doi:10.1016/s0262-8856(00)00058-5
- hill, 1999, assessment of intraoperative brain deformation using interventional mr imaging, Proc Medical Image Computing and Computer-Assisted Intervention (MICCAI 99), 1679, 910, 10.1007/10704282_99 · doi:10.1007/10704282_99
- 10.1007/3-540-45468-3_7 · doi:10.1007/3-540-45468-3_7
- 10.1097/00004728-199707000-00007 · DOI · Paper page
- 10.1117/12.154499 · doi:10.1117/12.154499
- 10.1109/38.75587 · doi:10.1109/38.75587
- 10.1109/ICPR.1994.576365 · doi:10.1109/icpr.1994.576365
- malandain, 1995, Physically based rigid registration of 3-D free-form objects Application to medical imaging
- 10.1109/42.232253 · doi:10.1109/42.232253
- 10.1227/00006123-199410000-00016 · doi:10.1227/00006123-199410000-00016
- studholme, 1996, registration measures for automated 3-d alignment of pet and intensity distorted mr images, Proc Image Fusion and Shape Variability Techniques, 186
- rohde, 2001, adaptive free-form deformation for inter-patient medical image registration, Proc SPIE Medical Imaging Image Processing, 4322, 1578
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging (IPMI 95), 3, 287
- 10.1117/12.208680 · doi:10.1117/12.208680
- schnabel, 2001, a generic framework for nonrigid registration based on nonuniform multilevel free-form deformations, Proc SpMedical Image Computing and Computer-Assisted Intervention (MICCAI 01), 2208, 573
- 10.1109/4233.767087 · doi:10.1109/4233.767087
- christensen, 1995, topological properties of smooth anatomic maps, Proc Information Processing in Medical Imaging (IPMI 95), 3, 101
- clarkson, 1999, registration of video images to tomographic images by optimising mutual information using texture mapping, Proc Medical Image Computing and Computer-Assisted Intervention (MICCAI 99), 1679, 579, 10.1007/10704282_62 · doi:10.1007/10704282_62
- pluim, 1996, Multi-modality matching using mutual information
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging (IPMI 95), 3, 263
- 10.1117/12.387699 · doi:10.1117/12.387699
- 10.1109/10.495282 · doi:10.1109/10.495282
- press, 1992, Numerical Recipes in C
Cited by
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
SuperFusion: A Versatile Image Registration and Fusion Network with Semantic Awareness
Tang, L., Deng, Y., Ma, Y., Huang, J., & Ma, J. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.106082 · Cited by 488
Directive Contrast Based Multimodal Medical Image Fusion in NSCT Domain
Bhatnagar, G., Wu, Q. M. J., & Liu, Z. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244870 · Cited by 471
Zaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Metadata
- Authors
- Maes, F., Vandermeulen, D., & Suetens, P.
- Venue
- Proceedings of the IEEE
- Published
- 2003-10
- Volume
- 91
- Issue
- 10
- Pages
- 1699-1722
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2109115250
- Cited by
- 432
- References
- 102
- FWCI
- 18.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.