Silicon-Integrated High-Density Electrocortical Interfaces
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Recent demand and initiatives in brain research have driven significant interest toward developing chronically implantable neural interface systems with high spatiotemporal resolution and spatial coverage extending to the whole brain. Electroencephalography-based systems are noninvasive and cost efficient in monitoring neural activity across the brain, but suffer from fundamental limitations in spatiotemporal resolution. On the other hand, neural spike and local field potential (LFP) monitoring with penetrating electrodes offer higher resolution, but are highly invasive and inadequate for long-term use in humans due to unreliability in long-term data recording and risk for infection and inflammation. Alternatively, electrocorticography (ECoG) promises a minimally invasive, chronically implantable neural interface with resolution and spatial coverage capabilities that, with future technology scaling, may meet the needs of recently proposed brain initiatives. In this paper, we discuss the challenges and state-of-the-art technologies that are enabling next-generation fully implantable high-density ECoG interfaces, including details on electrodes, data acquisition front-ends, stimulation drivers, and circuits and antennas for wireless communications and power delivery. Along with state-of-the-art implantable ECoG interface systems, we introduce a modular ECoG system concept based on a fully encapsulated neural interfacing acquisition chip (ENIAC). Multiple ENIACs can be placed across the cortical surface, enabling dense coverage over wide area with high spatiotemporal resolution. The circuit and system level details of ENIAC are presented, along with measurement results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“Safety is of the utmost importance in chronic neural interfaces, so charge balancing is imperative [96].”
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“and have substantial limitations in long-term chronic applications due to their susceptibility to signal degradation from electrode displacement and immune response against the electrodes [10].”
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878 · cited 1×
“Near-field power transfer, which operates at frequencies up to approximately 100 MHz for typical implants, has been extensively used for cochlear implants [135], retinal prostheses [86], [93], and various research IMD systems [122], [136]–[139], and has been investigated and characterized to maximize its usage and pow…”
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Yu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523 · cited 1×
“Furthermore, recent advances in dissolvable flexible electronics [188], [189] offer alternatives to hermetic encapsulation for acute applications without the need for post-use surgical extraction.”
Cited by
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Kim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104
Self-citationLyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
A Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Self-citationThe Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
Metadata
- Authors
- Ha, S., Akinin, A., Park, J., Kim, C., Wang, H., Maier, C., Mercier, P. P., & Cauwenberghs, G.
- Venue
- Proceedings of the IEEE
- Published
- 2017-01
- Volume
- 105
- Issue
- 1
- Pages
- 11-33
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2505594344
- Cited by
- 84
- References
- 35
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.