Biocompatible SU-8-Based Microprobes for Recording Neural Spike Signals From Regenerated Peripheral Nerve Fibers
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A biocompatible neural microprobe constructed using well-established SU-8 microfabrication techniques is described that was designed to record fiber spike signals from regenerated axons within peripheral nerves. These microprobes features bipolar longitudinal gold electrodes recessed below the surface within ldquogroovesrdquo designed to guide the growth of regenerating axons along the length of the grooves and limit the number of fibers that come in contact with the longitudinal electrodes. In addition, screening microprobe toxicity using cultures of human skin fibroblasts, the biocompatibility of these SU-8 microprobes for neural interface applications, in particular, was specifically verified using primary cultures of two sensitive cell types found in peripheral nerves: purified Schwann cells and explanted dorsal root ganglion (DRG) neurons and their fibers. The SU-8 microprobes were surgically implanted into transected rat Sciatic nerves within a unique peripheral nerve regeneration tube. Long-term fiber spike signals were recorded with these SU-8 microprobes in 13 chronically implanted rats for periods from 4 to 51 weeks without any signs of tissue damage or inflammatory reaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“microelectrodes that can detect or stimulate neural activity throughout the nervous system [3].”
BackgroundLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · cited 1×
“Neural spike signals can be used to control the movement of prosthetic limbs or other assistive robotics [1].”
BackgroundRiso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · cited 1×
“electrode/fiber interface [9].”
Cited by
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
In vitro and in vivo evaluation of SU-8 biocompatibility
Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.07.001 · Cited by 262
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Metadata
- Authors
- Cho, S.-H., Lu, H. M., Cauller, L., Romero-Ortega, M. I., Lee, J.-B., & Hughes, G. A.
- Venue
- IEEE Sensors Journal
- Published
- 2008-11
- Volume
- 8
- Issue
- 11
- Pages
- 1830-1836
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2107424187
- Cited by
- 112
- References
- 5
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.