Compact Sensing Design of a Handheld Active Tremor Compensation Instrument
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Active physiological tremor compensation instruments have been under research and development recently. The sensing unit of the instruments provides information on three degrees-of-freedom (DOF) motion of the instrument tip using accelerations provided by accelerometers placed inside the instruments. A complete vector of angular acceleration of the instrument needs to be known to obtain information on three DOF motions of the tip. Sensing resolution of angular acceleration about the instrument axis is directly proportional to the width of the proximal-end sensing unit. To keep the sensing resolution high enough, the width of the unit has to be made large. As a result, the proximal-end sensing unit of the instruments is bulky. In this paper, placement of accelerometers is proposed such that the angular acceleration about the instrument axis need not be known to obtain information on the three DOF motions of the tip. With the proposed placement, the instrument is no longer bulky and fewer number of accelerometers is required, thereby making the instrument compact and better in terms of ergonomics and reliability. Experiments were conducted to show that the proposed design of placement works properly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Evaluation of a Telerobotic System to Assist Surgeons in Microsurgery
Das, H., Zak, H., Johnson, J., Crouch, J., & Frambach, D. (1999) · Computer Aided Surgery · doi:10.3109/10929089909148155 · Cited by 116
ERGONOMICS APPLIED TO THE PRACTICE OF MICROSURGERY1
Patkin, M. (1977) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1977.tb04297.x · Cited by 80
Ang, W. T., Khosla, P. K., & Riviere, C. N. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1241852 · Cited by 66
Self-citationDesign and Calibration of an Optical Micro Motion Sensing System for Micromanipulation Tasks
Win, T. L., Tan, U. X., Shee, C. Y., & Ang, W. T. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.363995 · Cited by 25 · cited 1×
“The tip of the rod was attached with a reflective ball whose location was sensed using an optical-based micro motion sensing system, [14], [15].”
MethodSelf-citation
Research works printed but not linked: 10
- 10.1109/ROBIO.2009.4913014 · DOI
- 10.1109/ROBIO.2009.4913049 · DOI
- 10.1109/IEMBS.2008.4649570 · DOI
- 10.1109/BIOROB.2008.4762893 · DOI
- ang, 2001, design and implementation of active error canceling in a hand-held microsurgical instrument, IEEE/RSJ Int Conf Intell Robots Syst, 1106
- 10.2514/3.21195 · DOI · Paper page
- ang, 2004, Active tremor compensation in handheld instrument for microsurgery
- wang, 2003, a new scheme of non-gyro inertial measurement unit for estimating angular velocity, Proc 29th Annu Conf IEEE Ind Electron Soc, 2, 1564, 10.1109/IECON.2003.1280290 · doi:10.1109/iecon.2003.1280290
- 10.1115/1.1386649 · doi:10.1115/1.1386649
- 10.1109/TIM.2005.858129 · DOI · Paper page
Cited by
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Self-citationTatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
Self-citationMultistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Self-citationShahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Metadata
- Authors
- Latt, W. T., Tan, U.-X., Shee, C. Y., Riviere, C. N., & Ang, W. T.
- Venue
- IEEE Sensors Journal
- Published
- 2009-12
- Volume
- 9
- Issue
- 12
- Pages
- 1864-1871
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2168424073
- Cited by
- 39
- References
- 5
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compact Sensing Design of a Handheld Active Tremor Compensation Instrument. https://app.cochat.ai/papers/10.1109/jsen.2009.2030980
- The paper
- Latt, W. T., Tan, U.-X., Shee, C. Y., Riviere, C. N., & Ang, W. T. (2009). Compact Sensing Design of a Handheld Active Tremor Compensation Instrument. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2009.2030980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.