A Study on Breath Acetone in Diabetic Patients Using a Cavity Ringdown Breath Analyzer: Exploring Correlations of Breath Acetone With Blood Glucose and Glycohemoglobin A1C
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Acetone is qualitatively known as a biomarker of diabetes; however, the quantitative information on acetone concentration in diabetic breath is incomplete, and the knowledge of correlations of breath acetone with diabetic diagnostic parameters, namely, blood glucose (BG) and glycohemoglobin A1C (A1C), are unknown. We utilized a pilot-scale breath acetone analyzer based on the cavity ringdown spectroscopy (CRDS) technique to conduct breath tests with 34 Type 1 diabetic (T1D), ten Type 2 diabetic (T2D) patients, and 15 apparently healthy individuals. Relations between breath acetone and BG, A1C, and several other bio indices, such as the type of diabetes, onset-time, gender, age, and weight were investigated. Our observations show that a linear correlation between the mean group acetone and the mean group BG level does exist (R = 0.98, P < 0.02) when all the T1D subjects tested are grouped by different BG levels, 40-100, 101-150, 151-200, and 201-419 mg/dL. Similarly, among the T1D subjects studied, when their A1C's are grouped by < 7, 7-9.9, and 10-13, a linear correlation between the mean group A1C and the mean group acetone concentration is observed (R = 0.98, P < 0.02). No strong correlations are observed when the BG and A1C numbers are not grouped. The mean breath acetone concentration in the T1D subjects studied in this work is determined to be 2.19 ppmv (parts per million by volume), which is higher than the mean breath acetone concentration, 0.48 ppmv, in the 15 healthy people tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
O’Keefe, A., & Deacon, D. A. G. (1988) · Review of Scientific Instruments · doi:10.1063/1.1139895 · Cited by 1,741 · cited 7×
“1) Ringdown Breath Acetone Analyzer: The instrument’s principle is based on cavity ringdown spectroscopy (CRDS) [ 29 ], which has been described in detail in several excellent reviews (just to list a few) [30]‐[33].”
BackgroundMethodInfluentialNowy rok, stare problemy, ale i nowe możliwości
Czupryniak, L., & Diabetologicznego, P. P. T. (2014) · Via Medica Journals · Cited by 1,192
Defining the Relationship Between Plasma Glucose and HbA1c
Rohlfing, C. L., Wiedmeyer, H.-M., Little, R. R., England, J. D., Tennill, A., & Goldstein, D. E. (2002) · Diabetes Care · doi:10.2337/diacare.25.2.275 · Cited by 987 · cited 1×
“In theory, it is well documented that BG level is correlated with A1C level and the correlation coefficient can be up to [ 36 ], [37].”
BackgroundVariation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 371
Standards of medical care for patients with diabetes mellitus
(1989) · The Journal of the American Osteopathic Association · doi:10.1515/jom-1989-890715 · Cited by 362
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Cited by
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127274 · Cited by 338
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Self-citationSensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 192
Electronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Research progress of electronic nose technology in exhaled breath disease analysis
Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00594-0 · Cited by 165
Human body-odor components and their determination
Pandey, S. K., & Kim, K.-H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.12.005 · Cited by 121
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105
Metadata
- Authors
- Wang, C., Mbi, A., & Shepherd, M.
- Venue
- IEEE Sensors Journal
- Published
- 2010-01
- Volume
- 10
- Issue
- 1
- Pages
- 54-63
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2138217742
- Cited by
- 236
- References
- 28
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.