The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Sensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Abstract
The rapid aging of the world's population, along with an increase in the prevalence of chronic illnesses and obesity, requires adaption and modification of current healthcare models. One such approach involves telehealth applications, many of which are based on sensor technologies for unobtrusive monitoring. Recent technological advances, in particular, involving microelectromechnical systems, have resulted in miniaturized wearable devices that can be used for a range of applications. One of the leading areas for utilization of body-fixed sensors is the monitoring of human movement. An overview of common ambulatory sensors is presented, followed by a summary of the developments in this field, with an emphasis on the clinical applications of falls detection, falls risk assessment, and energy expenditure. The importance of these applications is considerable in light of the global demographic trends and the resultant rise in the occurrence of injurious falls and the decrease of physical activity. The potential of using such monitors in an unsupervised manner for community-dwelling individuals is immense, but entails an array of challenges with regards to design c onsiderations, implementation protocols, and signal analysis processes. Some limitations of the research to date and suggestions for future research are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance‐Oriented Assessment of Mobility Problems in Elderly Patients
Tinetti, M. E. (1986) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1986.tb05480.x · Cited by 3,352
Fall risk index for elderly patients based on number of chronic disabilities
Tinetti, M. E., Franklin Williams, T., & Mayewski, R. (1986) · The American Journal of Medicine · doi:10.1016/0002-9343(86)90717-5 · Cited by 1,587
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Self-citationBouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
A physiological profile approach to falls risk assessment and prevention
(2007) · Falls in Older People · doi:10.1017/cbo9780511722233.018 · Cited by 886
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Self-citationSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Najafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Bula, C. J., & Robert, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812189 · Cited by 762
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Estimation of gait cycle characteristics by trunk accelerometry
Moe-Nilssen, R., & Helbostad, J. L. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00233-1 · Cited by 640
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Smart homes — Current features and future perspectives
Chan, M., Campo, E., Estève, D., & Fourniols, J.-Y. (2009) · Maturitas · doi:10.1016/j.maturitas.2009.07.014 · Cited by 585
Tiedemann, A., Shimada, H., Sherrington, C., Murray, S., & Lord, S. (2008) · Age and Ageing · doi:10.1093/ageing/afn100 · Cited by 548
Fall Risk Assessment Measures: An Analytic Review
Perell, K. L., Nelson, A., Goldman, R. L., Luther, S. L., Prieto-Lewis, N., & Rubenstein, L. Z. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.12.m761 · Cited by 546
Comparison of low-complexity fall detection algorithms for body attached accelerometers
Kangas, M., Konttila, A., Lindgren, P., Winblad, I., & Jämsä, T. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.003 · Cited by 493
Falls in Older People. Risk Factors and Strategies for Prevention
Close, J. C. T. (2003) · Age and Ageing · doi:10.1093/ageing/32.4.467-a · Cited by 477
Najafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800763 · Cited by 442
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“where sensors are woven into real wearable objects, such as shirts and vests [7].”
BackgroundWireless sensor network based wearable smart shirt for ubiquitous health and activity monitoring
Lee, Y.-D., & Chung, W.-Y. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.040 · Cited by 382
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Aminian, K., Robert, P., Buchser, E. E., Rutschmann, B., Hayoz, D., & Depairon, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513304 · Cited by 308
Assessment of spatio-temporal parameters during unconstrained walking
Zijlstra, W. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1041-5 · Cited by 296
Barometric Pressure and Triaxial Accelerometry-Based Falls Event Detection
Bianchi, F., Redmond, S. J., Narayanan, M. R., Cerutti, S., & Lovell, N. H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2070807 · Cited by 296
Self-citationEvaluation of a fall detector based on accelerometers: A pilot study
Lindemann, U., Hock, A., Stuber, M., Keck, W., & Becker, C. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351026 · Cited by 292
Quantitative Falls Risk Assessment Using the Timed Up and Go Test
Greene, B. R., O'Donovan, A., Romero-Ortuno, R., Cogan, L., Scanaill, C. N., & Kenny, R. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2083659 · Cited by 261
Standing balance evaluation using a triaxial accelerometer
Mayagoitia, R. E., Lötters, J. C., Veltink, P. H., & Hermens, H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00199-0 · Cited by 249
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a24536 · Cited by 245
Menz, H. B., Lord, S. R., & Fitzpatrick, R. C. (2003) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/58.5.m446 · Cited by 243
Detection of daily physical activities using a triaxial accelerometer
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348434 · Cited by 237
Self-citationA Wearable Airbag to Prevent Fall Injuries
Tamura, T., Yoshimura, T., Sekine, M., Uchida, M., & Tanaka, O. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033673 · Cited by 223
Bourke, A. K., van de Ven, P., Gamble, M., O’Connor, R., Murphy, K., Bogan, E., McQuade, E., Finucane, P., ÓLaighin, G., & Nelson, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.005 · Cited by 215
The design of a practical and reliable fall detector for community and institutional telecare
Doughty, K., Lewis, R., & Mcintosh, A. (2000) · Journal of Telemedicine and Telecare · doi:10.1258/1357633001934483 · Cited by 185
Falls in Older People: Risk Factors and Strategies for Prevention
Levy, L. A. (2002) · Journal of the American Podiatric Medical Association · doi:10.7547/87507315-92-6-371 · Cited by 161
Comparison of acceleration signals of simulated and real-world backward falls
Klenk, J., Becker, C., Lieken, F., Nicolai, S., Maetzler, W., Alt, W., Zijlstra, W., Hausdorff, J. M., van Lummel, R. C., Chiari, L., et al. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.11.003 · Cited by 161
Mobility assessment in older people: new possibilities and challenges
Zijlstra, W., & Aminian, K. (2007) · European Journal of Ageing · doi:10.1007/s10433-007-0041-9 · Cited by 155
A pilot study of long-term monitoring of human movements in the home using accelerometry
Mathie, M. J., Coster, A. C. F., Lovell, N. H., Celler, B. G., Lord, S. R., & Tiedemann, A. (2004) · Journal of Telemedicine and Telecare · doi:10.1258/135763304323070788 · Cited by 153
Self-citationBourke, A. K., O’Donovan, K. J., & OLaighin, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.12.003 · Cited by 145
Detecting Balance Deficits in Frequent Fallers Using Clinical and Quantitative Evaluation Tools
Cho, C., & Kamen, G. (1998) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1998.tb02461.x · Cited by 138
Allum, J. H., & Carpenter, M. G. (2005) · Current Opinion in Neurology · doi:10.1097/00019052-200502000-00005 · Cited by 133
A body-fixed-sensor-based analysis of power during sit-to-stand movements
Zijlstra, W., Bisseling, R. W., Schlumbohm, S., & Baldus, H. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.003 · Cited by 129
Estimation of speed and incline of walking using neural network
Aminian, K., Robert, P., Jéquier, E., & Schutz, Y. (1995) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.387322 · Cited by 114
The potential impact of home telecare on clinical practice
Celler, B. G., Lovell, N. H., & Chan, D. K. Y. (1999) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb123782.x · Cited by 112
Self-citationA smart sensor based on rules and its evaluation in daily routines
Noury, N., Barralon, P., Virone, G., Boissy, P., Hamel, M., & Rumeau, P. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280846 · Cited by 106
Testing of a long-term fall detection system incorporated into a custom vest for the elderly
Bourke, A. K., van de Ven, P. W. J., Chaya, A. E., OLaighin, G. M., & Nelson, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649795 · Cited by 95
Can accelerometry accurately predict the energy cost of uphill/downhill walking?
Terrier, P., Aminian, K., & Schutz, Y. (2001) · Ergonomics · doi:10.1080/00140130118289 · Cited by 93
Longitudinal Falls-Risk Estimation Using Triaxial Accelerometry
Narayanan, M. R., Redmond, S. J., Scalzi, M. E., Lord, S. R., Celler, B. G., & Lovell, N. H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033038 · Cited by 93
Self-citationAutomated detection of near falls: algorithm development and preliminary results
Weiss, A., Shimkin, I., Giladi, N., & Hausdorff, J. M. (2010) · BMC Research Notes · doi:10.1186/1756-0500-3-62 · Cited by 72
Quantification of everyday motor function in a geriatric population
de Bruin, E. D., Najafi, B., Murer, K., Uebelhart, D., & Aminian, K. (2007) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2006.01.0003 · Cited by 71
Bussmann, J. B., Veltink, P. H., Koelma, F., van Lummel, R. C., & Stam, H. J. (1995) · University of Twente Research Information · Cited by 68
Marschollek, M., Nemitz, G., Gietzelt, M., Wolf, K.-H., zu Schwabedissen, H. M., & Haux, R. (2009) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-009-0035-7 · Cited by 67
Giansanti, D., Macellari, V., & Maccioni, G. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/3/n01 · Cited by 54
Ohtaki, Y., Susumago, M., Suzuki, A., Sagawa, K., Nagatomi, R., & Inooka, H. (2005) · Microsystem Technologies · doi:10.1007/s00542-005-0502-z · Cited by 53
Classification of walking patterns on inclined surfaces from accelerometry data
Wang, N., Eliathamby Ambikairajah, A., Redmond, S. J., Celler, B. G., & Lovell, N. H. (2009) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2009.5201202 · Cited by 17
Self-citation
Cited by
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
SisFall: A Fall and Movement Dataset
Sucerquia, A., López, J., & Vargas-Bonilla, J. (2017) · Sensors · doi:10.3390/s17010198 · Cited by 530
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
Pasluosta, C. F., Gassner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2461555 · Cited by 323
Depth-Based Human Fall Detection via Shape Features and Improved Extreme Learning Machine
Ma, X., Wang, H., Xue, B., Zhou, M., Ji, B., & Li, Y. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2304357 · Cited by 286
Metadata
- Authors
- Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H.
- Venue
- IEEE Sensors Journal
- Published
- 2012-03
- Volume
- 12
- Issue
- 3
- Pages
- 658-670
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2056020968
- Cited by
- 285
- References
- 57
- FWCI
- 15.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.