Photoplethysmography-Based Heart Rate Monitoring Using Asymmetric Least Squares Spectrum Subtraction and Bayesian Decision Theory
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Motion artifacts (MAs) are strong interference sources in wearable photoplethysmography (PPG) signals, significantly affecting estimation of heart rate (HR) and other physiological parameters. In this paper, a novel method called SPECTRAP is proposed for accurate motion-tolerant estimation of HR using a PPG signal and a simultaneous acceleration signal. The method first calculates the spectra of the PPG signal and the acceleration signal, and then removes the MA spectral components from the PPG spectrum using a new spectrum subtraction algorithm. The new spectrum subtraction algorithm is based on asymmetric least square and overcomes drawbacks of the conventional spectrum subtraction algorithms. To find the spectral peak corresponding to HR on the resulting spectrum, SPECTRAP formulates the problem into a pattern classification problem and uses the Bayesian decision theory to solve it. Experimental results on the PPG database used in 2015 IEEE Signal Processing Cup showed that the proposed algorithm has excellent performance. The average absolute error on the twelve training sets was 1.50 beat per minute (BPM) (standard deviation: 1.95 BPM). The average absolute error on the ten testing sets was 2.13 BPM (standard deviation: 2.77 BPM).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · cited 2×
“Later, the method was improved by using an advanced sparse signal recovery model and SS [24].”
MethodSelf-citation
Cited by
Deep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Van Laerhoven, K. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 377
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 293
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simoes-Capela, N., Van Hoof, C., & Van Helleputte, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 258
Materials and Wearable Devices for Autonomous Monitoring of Physiological Markers
Wu, W., & Haick, H. (2018) · Advanced Materials · doi:10.1002/adma.201705024 · Cited by 208
Advanced materials of printed wearables for physiological parameter monitoring
Sreenilayam, S. P., Ahad, I. U., Nicolosi, V., Acinas Garzon, V., & Brabazon, D. (2020) · Materials Today · doi:10.1016/j.mattod.2019.08.005 · Cited by 171
Ye, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94
“Using our proposed algorithm can obtain accurate estimation of HR with the averages of 12 subjects’ recordings about Error1 being 1.16 ± 2.23, and Error2 being 0.93%, respectively, which was better than several excellent algorithms proposed in the last two years, namely TROIKA [17], JOSS [22], and SPECTRAP [23].”
BackgroundResultSelf-citationMotion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37
“Another concern lies in the appropriate strategy used for picking out noise-related components, which leads to various spectrum subtraction methods, trying to suppress MA related components with the help of motion reference signals [17], [18].”
BackgroundLee, H., Chung, H., Kim, J.-W., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894640 · Cited by 22
“Other tracking algorithms feature the correction of the estimated HR by assigning the prior HR if the present estimate differs too much from the previous estimate [6], [17], [20].”
Result
Metadata
- Authors
- Sun, B., & Zhang, Z.
- Venue
- IEEE Sensors Journal
- Published
- 2015-12
- Volume
- 15
- Issue
- 12
- Pages
- 7161-7168
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W1910786341
- Cited by
- 115
- References
- 3
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.