Empowering Technology Enabled Care Using IoT and Smart Devices: A Review
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Designing power aware wearable devices is the main key in building compact size autonomous smart devices to successfully connect health Internet of things solutions. With their ability to perform tasks ranging from simple self-monitoring to complex interactive tasks, these devices hold great promises in providing a large scale cost effective solution to the challenges facing nowadays healthcare systems. Despite the advances in sensing and hardware design, there still remain several technical challenges facing the research community to build devices that meet the computational requirements with a self-powered capability. Overcoming these challenges require major improvements in all the building blocks of wearable devices including sensors, power management, signal processing, computing architectures, and communication. This paper surveys some of the past milestones related to these subsystems and discusses promising research directions addressing their limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
Low power wide area networks: an overview
Raza, U., Kulkarni, P., & Sooriyabandara, M. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2652320 · Cited by 2,047 · cited 1×
“20) and with a relatively high latency in the order of seconds to minutes [161].”
BackgroundEnergy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888 · cited 1×
“A large number piezoelectric motion (knees, foot, heart beating, ankle, wrist) harvesters have been reported in the literature with unprocessed power densities between a few μW/cm2 to tens of W/cm2 depending on the motion source and the harvester efficiency [110].”
BackgroundA low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227 · cited 1×
“It also gives superior results compared to clinic BP, which is found to be prone to white-coat effect [75].”
ResultToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 2×
“It is worth noting that oscillometry is not reliable in case of pregnancy and with subjects having conditions such as atrial fibrillation and stiff arteries [73], [74].”
BackgroundA micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441 · cited 2×
“CIA stage to shape the pass band of the amplifier [44].”
BackgroundOrphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Cited by
The Future of Healthcare Internet of Things: A Survey of Emerging Technologies
Qadri, Y. A., Nauman, A., Zikria, Y. B., Vasilakos, A. V., & Kim, S. W. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2973314 · Cited by 840
Javed, A. R., Shahzad, F., Rehman, S. U., Zikria, Y. B., Razzak, I., Jalil, Z., & Xu, G. (2022) · Cities · doi:10.1016/j.cities.2022.103794 · Cited by 606
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
A study on medical Internet of Things and Big Data in personalized healthcare system
Jagadeeswari, V., Subramaniyaswamy, V., Logesh, R., & Vijayakumar, V. (2018) · Health Information Science and Systems · doi:10.1007/s13755-018-0049-x · Cited by 321
Edge Intelligence and Internet of Things in Healthcare: A Survey
Amin, S. U., & Hossain, M. S. (2021) · IEEE Access · doi:10.1109/access.2020.3045115 · Cited by 260
Choudhury, A. (2022) · JMIR Human Factors · doi:10.2196/35421 · Cited by 56
(2021) · doi:10.2196/24127 · Cited by 40
Hui, C. Y., McKinstry, B., Fulton, O., Buchner, M., & Pinnock, H. (2021) · Journal of Medical Internet Research · doi:10.2196/22432 · Cited by 17
“The IoT health care network has defined an IoT topology [16], which is an architecture and platform that can be used for diagnosis, personalized medication, emergency service, home rehabilitation, remote surgery remote monitoring, and self-management of conditions such as diabetes [17-20], hypertension [18,21], and as…”
Background
Metadata
- Authors
- Baali, H., Djelouat, H., Amira, A., & Bensaali, F.
- Venue
- IEEE Sensors Journal
- Published
- 2018-03-01
- Volume
- 18
- Issue
- 5
- Pages
- 1790-1809
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2776562740
- Cited by
- 63
- References
- 18
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.