Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
The DOI matches its Crossref record.
Abstract
The new class of amplifiers described is based on a load network synthesized to have a transient response which maximizes power efficiency even if the active device switching times are substantial fractions of the a.c. cycle. The new class of amplifiers, named `Class E,' is defined and is illustrated by a detailed description and a set of design equations for one simple member of the class. For that circuit the authors measured 96 percent transistor efficiency at 3.9 MHz at 26-W output from a pair of Motorola 2N3735 TO-5 transistors. Advantages of Class E are unusually high efficiency, a priori designability, large reduction in second-breakdown stress, low sensitivity to active-device characteristics, and potential for high-efficiency operation at higher frequencies than previously published Class-D circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“A highly efficient Class-E power amplifier is typically used in the present cochlear implants [90], [91].”
MethodJow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Opportunities and Challenges in Very High Frequency Power Conversion
Perreault, D. J., Hu, J., Rivas, J. M., Han, Y., Leitermann, O., Pilawa-Podgurski, R. C. N., Sagneri, A., & Sullivan, C. R. (2009) · 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802625 · Cited by 476
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Exact analysis of class E tuned power amplifier at any Q and switch duty cycle
Kazimierczuk, M., & Puczko, K. (1987) · IEEE Transactions on Circuits and Systems · doi:10.1109/tcs.1987.1086114 · Cited by 372
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Maximizing DC-to-Load Efficiency for Inductive Power Transfer
Pinuela, M., Yates, D. C., Lucyszyn, S., & Mitcheson, P. D. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215887 · Cited by 354
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Designing Efficient Inductive Power Links for Implantable Devices
Harrison, R. R. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378508 · Cited by 244
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“be considered along with the driver’s efficiency [4].”
Zierhofer, C. M., & Hochmair, E. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55682 · Cited by 214
An inductive power link for a wireless endoscope
Lenaerts, B., & Puers, R. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.015 · Cited by 204
“The diode allows for suboptimum operation, i.e. a class C behaviour (Sokal and Sokal, 1975; Kazimierczuk and Czarkowski, 1995).”
BackgroundGhovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.905187 · Cited by 202
“On the transmitter side, a high efficiency class-E power amplifier, tuned at kHz, drove from a dc supply [37]–[39].”
Atluri, S., & Ghovanloo, M. (2006) · 2006 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2006.1692789 · Cited by 196
“On the transmitter side, a high efficiency class-E power amplifier, tuned at kHz, drove from a dc supply [37]–[39].”
BackgroundWireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S.-C., & Thakor, N. V. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 184
“Class E amplifiers [33] with operating efficiency of over 90% have been reported for use in the sub-GHz range and can be used as a powering source.”
BackgroundArteaga, J. M., Aldhaher, S., Kkelis, G., Kwan, C., Yates, D. C., & Mitcheson, P. D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2871188 · Cited by 181
“g Class E [31], EF2 [32], Φ2 [33], the load-independent achieves ZVS for the entire resistive load range.”
BackgroundClosed-loop class E transcutaneous power and data link for MicroImplants
Troyk, P. R., & Schwan, M. A. K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141197 · Cited by 177
Evaluation of Magnetic Materials for Very High Frequency Power Applications
Han, Y., Cheung, G., Li, A., Sullivan, C. R., & Perreault, D. J. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159995 · Cited by 175
Electronic Tuning of Misaligned Coils in Wireless Power Transfer Systems
Aldhaher, S., Luk, P. C.-K., & Whidborne, J. F. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2297993 · Cited by 162
“The Class E inverter, invented by the Sokals in 1975 [16], is a certain class of amplifiers that has been widely used recently as the primary coil driver in resonant inductive links due to its simplicity, high efficiency and high power delivering capability [5], [17]–[24].”
BackgroundInductive link design for medical implants
Ali, H., Ahmad, T. J., & Khan, S. A. (2009) · 2009 IEEE Symposium on Industrial Electronics & Applications · doi:10.1109/isiea.2009.5356376 · Cited by 41
Metadata
- Authors
- Sokal, N. O., & Sokal, A. D.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 1975-06
- Volume
- 10
- Issue
- 3
- Pages
- 168-176
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W83868485
- Cited by
- 2,033
- References
- 0
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.