The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
An Efficiency-Enhanced CMOS Rectifier With Unbalanced-Biased Comparators for Transcutaneous-Powered High-Current Implants
Abstract
This paper presents an efficiency-enhanced integrated full-wave CMOS rectifier for the transcutaneous power transmission in high-current biomedical implants. The comparator-controlled switches are developed to minimize the voltage drop along the conducting path while achieving the unidirectional current flow. The proposed unbalanced-biasing scheme also minimizes the reverse leakage current of the rectifier under different input amplitudes, thereby optimizing the rectifier power efficiency. Moreover, the proposed rectifier is able to self start and operates at low input amplitudes. Implemented in a standard 0.35mum CMOS process with maximum threshold voltages of |Vthp| = 0.82 V and Vthn= 0.69 V, the rectifier can source a maximum output current of 20 mA and operate properly with inputs of different amplitudes and frequencies. With a 1.5 MHz input of 1.2 V amplitude, the proposed rectifier can achieve the peak voltage conversion ratio of 95% and the power efficiency of at least 82%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog Integrated Circuit Design
Carusone, A. C., Johns, D. A., & Martin, K. W. (1996) · Cited by 2,509
Analog integrated circuit design
Hurst, S. L. (1998) · Microelectronics Journal · doi:10.1016/s0026-2692(97)00051-7 · Cited by 1,732
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Fully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Power harvesting and telemetry in CMOS for implanted devices
Sauer, C., Stanacevic, M., Cauwenberghs, G., & Thakor, N. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.858183 · Cited by 249
Integrated Low-Loss CMOS Active Rectifier for Wirelessly Powered Devices
Lam, Y.-H., Ki, W.-H., & Tsui, C.-Y. (2006) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2006.885400 · Cited by 246
The impact of scaling down to deep submicron on CMOS RF circuits
Huang, Q., Piazza, F., Orsatti, P., & Ohguro, T. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.701249 · Cited by 246
An Ultra-Low-Power Programmable Analog Bionic Ear Processor
Sarpeshkar, R., Salthouse, C., Sit, J.-J., Baker, M. W., Zhak, S. M., Lu, T. K.-T., Turicchia, L., & Balster, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844043 · Cited by 171
A 0.5-mW passive telemetry IC for biomedical applications
Huang, Q., & Oberle, M. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.701225 · Cited by 170
A 32-Site 4-Channel High-Density Electrode Array for a Cochlear Prosthesis
Bhatti, P. T., & Wise, K. D. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884862 · Cited by 112
Vaillancourt, P., Djemouai, A., Harvey, J. F., & Sawan, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.756835 · Cited by 79
On-Chip Active Power Rectifiers for Biomedical Applications
Lehmann, T., & Moghe, Y. (2005) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2005.1464692 · Cited by 53
Wirelessly powered and bidirectional data exchanged in smart medical microsystems
Sawan, M., Hu, Y., & Coulombe, J. (2006) · IEEE Custom Integrated Circuits Conference (CICC) · doi:10.1109/cicc.2005.1568596 · Cited by 18
Cited by
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2387832 · Cited by 302
Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279
Rozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49
Metadata
- Authors
- Guo, S., & Lee, H.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-06
- Volume
- 44
- Issue
- 6
- Pages
- 1796-1804
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2125409887
- Cited by
- 253
- References
- 14
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.