The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
An Integrated 256-Channel Epiretinal Prosthesis
Abstract
This paper reports an integrated 256-channel epiretinal prosthesis integrated circuit (IC). This epiretinal prosthesis system consists of a power telemetry subsystem to deliver 100 mW power, a data telemetry subsystem to transfer 2 Mbps data, digital controllers to decode stimulation patterns, and a 256-channel stimulator to generate user programmable bi-phasic current stimuli. In this study, dual-band telemetry is adopted to achieve both high power efficiency and high data rate. Frequencies of 2 and 22 MHz are chosen for power and data carrier frequencies, respectively. A mixed-mode and multiple-voltage design is applied to the stimulator for withstanding a high-compliance voltage of ± 10 V at the output stage as well as for reducing the area of each pixel. To add flexibility to the stimulator, each pixel has a local digital controller, which enables the stimulator IC to generate 256 parallel stimulations with various pulse widths and amplitudes. The chip is fabricated in TSMC 0.18 μm 32 V CMOS process with 256 area pads constructed above the stimulus current drivers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis and Design of Analog Integrated Circuits
Betts, W. R. (1978) · Electronics and Power · doi:10.1049/ep.1978.0296 · Cited by 3,827
Analysis and Design of Analog Integrated Circuits
Gray, P. R., & Meyer, R. G. (1977) · Cited by 3,487
The theory of bandpass sampling
Vaughan, R. G., Scott, N. L., & White, D. R. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.134430 · Cited by 921
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Self-citationPattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259 · cited 1×
“Several approaches that target anatomically different regions of the visual pathway have been pursued, including visual cortex [1], [2], optic nerve [3], [4], and retina [5]–[13].”
BackgroundA 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
Ghovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.905187 · Cited by 202
Atluri, S., & Ghovanloo, M. (2006) · 2006 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2006.1692789 · Cited by 196
Perceptual thresholds and electrode impedance in three retinal prosthesis subjects
Mahadevappa, M., Weiland, J. D., Yanai, D., Fine, I., Greenberg, R. J., & Humayun, M. S. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848687 · Cited by 186
Self-citationWeiland, J. D., & Humayun, M. S. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922589 · Cited by 179
Self-citationWyatt, J., & Rizzo, J. (1996) · IEEE Spectrum · doi:10.1109/6.490056 · Cited by 175
Facial Recognition Using Simulated Prosthetic Pixelized Vision
Thompson, R. W., Barnett, G. D., Humayun, M. S., & Dagnelie, G. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0341 · Cited by 175
Self-citationVisually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 160
Self-citationReal and virtual mobility performance in simulated prosthetic vision
Dagnelie, G., Keane, P. A., Narla, V., Yang, L., Weiland, J. D., & Humayun, M. S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s11 · Cited by 136
Self-citationA Highly Flexible System for Microstimulation of the Visual Cortex: Design and Implementation
Coulombe, J., Sawan, M., & Gervais, J.-F. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.916026 · Cited by 129
A Dual Band Wireless Power and Data Telemetry for Retinal Prosthesis
Wang, G., Liu, W., Sivaprakasam, M., Zhou, M., Weiland, J. D., & Humayun, M. S. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260470 · Cited by 110
Self-citationA CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation
Rothermel, A., Liu, L., Aryan, N. P., Fischer, M. D., Wuenschmann, J., Kibbel, S., & Harscher, A. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2007436 · Cited by 109
Liu, W., & Hurnayun, M. S. (2004) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2004.1332672 · Cited by 105
Self-citationEvoked cortical potentials after electrical stimulation of the inner retina in rabbits
Walter, P., & Heimann, K. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170050358 · Cited by 81
Zhou, M., Yuce, M. R., & Liu, W. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2001881 · Cited by 79
Self-citationA Low-Power Fully Implantable 15-Channel Retinal Stimulator Chip
Theogarajan, L. S. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2004331 · Cited by 78
Silicon LSI-based smart stimulators for retinal prosthesis
Ohta, J., Tokuda, T., Kagawa, K., Furumiya, T., Uehara, A., Terasawa, Y., Ozawa, M., Fujikado, T., & Tano, Y. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705747 · Cited by 61
Intraocular epiretinal prosthesis to restore vision in blind humans
Mokwa, W., Goertz, M., Koch, C., Krisch, I., Trieu, H. K., & Walter, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650530 · Cited by 56
Visual neuroprosthesis: a non invasive system for stimulating the cortex
Piedade, M. S., Gerald, J. A. B., Sousa, L. A., Tavares, G. N., & Tomás, P. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.857923 · Cited by 55
Minimally Invasive Retinal Prosthesis
Theogarajan, L. S., Wyatt, J. L., Rizzo, J. F., Drohan, B., Markova, M. V., Kelly, S. K., Swider, G. M., Raj, M., Shire, D. B., Gingerich, M. D., et al. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696038 · Cited by 54
Implantable FES Stimulation Systems: What is Needed?
Troyk, P. R., & Donaldson, N. (2001) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2001.00196.x · Cited by 33
Implant electronics for intraocular epiretinal neuro-stimulators
Lehmann, T., Lovell, N. H., Suaning, G. J., Preston, P., Wong, Y. T., Dommel, N., Jung, L. H., Moghe, Y., & Das, K. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541427 · Cited by 10
Implantable System for Optic Nerve Visual Prosthesis
Niu, S., Niu, J., Liu, Y., Zhou, Y., Zhou, Y., & Ren, Q. (2007) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2007.4381997 · Cited by 4
Cited by
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2387832 · Cited by 302
Metadata
- Authors
- Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-09
- Volume
- 45
- Issue
- 9
- Pages
- 1946-1956
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2145662372
- Cited by
- 266
- References
- 31
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.