Abstract
This paper reports an integrated 256-channel epiretinal prosthesis integrated circuit (IC). This epiretinal prosthesis system consists of a power telemetry subsystem to deliver 100 mW power, a data telemetry subsystem to transfer 2 Mbps data, digital controllers to decode stimulation patterns, and a 256-channel stimulator to generate user programmable bi-phasic current stimuli. In this study, dual-band telemetry is adopted to achieve both high power efficiency and high data rate. Frequencies of 2 and 22 MHz are chosen for power and data carrier frequencies, respectively. A mixed-mode and multiple-voltage design is applied to the stimulator for withstanding a high-compliance voltage of ± 10 V at the output stage as well as for reducing the area of each pixel. To add flexibility to the stimulator, each pixel has a local digital controller, which enables the stimulator IC to generate 256 parallel stimulations with various pulse widths and amplitudes. The chip is fabricated in TSMC 0.18 μm 32 V CMOS process with 256 area pads constructed above the stimulus current drivers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis and Design of Analog Integrated Circuits
Betts, W. R. (1978) · Electronics and Power · doi:10.1049/ep.1978.0296 · Cited by 3,827
Analysis and Design of Analog Integrated Circuits
Gray, P. R., & Meyer, R. G. (1977) · Cited by 3,487
The theory of bandpass sampling
Vaughan, R. G., Scott, N. L., & White, D. R. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.134430 · Cited by 921
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“Third, to accommodate individual patients who may have varied thresholds [21], the waveform of the stimulus is required to have a large tuning range and”
BackgroundSelf-citationWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Self-citationPattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259 · cited 1×
“Several approaches that target anatomically different regions of the visual pathway have been pursued, including visual cortex [1], [2], optic nerve [3], [4], and retina [5]–[13].”
BackgroundA 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
Ghovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.905187 · Cited by 202
Cited by
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2387832 · Cited by 302
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Weiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Self-citationLee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227914 · Cited by 146
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“Cochlear implants and retinal stimulators [10] are excellent examples of successful neural interfacing technologies that have reached widespread clinical”
BackgroundA Complete 256-Electrode Retinal Prosthesis Chip
Tran, N., Bai, S., Yang, J., Chun, H., Kavehei, O., Yang, Y., Muktamath, V., Ng, D., Meffin, H., Halpern, M., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2298037 · Cited by 90
“This is the case for all reported retinal stimulator chips in [2], [8], [10], [14], [30], [35].”
BackgroundA Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
Self-citationIbrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
“WPT is vital in today’s implantable medical devices (IMDs) that interface with the central and peripheral nervous systems (CNS and PNS) for recording and stimulating neuronal activity using different modalities such as electricity, light, and ultrasound [10]–[15].”
A Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
CMOS stimulating chips capable of wirelessly driving 473 electrodes for a cortical vision prosthesis
Wong, Y. T., Feleppa, T., Mohan, A., Browne, D., Szlawski, J., Rosenfeld, J. V., & Lowery, A. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab021b · Cited by 27
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“The integration of variable-gain current mirrors in the output path provides flexibility in the range of output currents, with low-power digital control to minimize the area used [140], [141].”
Recent advances in power efficient output stage for high density implantable stimulators
Sooksood, K., Noorsal, E., Bihr, U., & Ortmanns, M. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346066 · Cited by 11
Overview of On-Chip Stimulator Designs for Biomedical Applications
Lin, C.-Y., & Ker, M.-D. (2012) · Journal of Neuroscience and Neuroengineering · doi:10.1166/jnsne.2012.1023 · Cited by 9
“Besides adding the blocking capacitor to block the dc leakage current, an alternative method for avoiding the charge accumulation in the tissue is to use a charge cancellation switch, as shown in Figure 18 [31].”
Method
Metadata
- Authors
- Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2010-09
- Volume
- 45
- Issue
- 9
- Pages
- 1946-1956
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2145662372
- Cited by
- 266
- References
- 31
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.