An 80-mVpp Linear-Input Range, 1.6-GΩ Input Impedance, Low-Power Chopper Amplifier for Closed-Loop Neural Recording That Is Tolerant to 650-mVpp Common-Mode Interference
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Closed-loop neuromodulation is essential for the advance of neuroscience and for administering therapy in patients suffering from drug-resistant neurological conditions. Neural stimulation generates large differential and commonmode (CM) artifacts at the recording sites, which easily saturate traditional recording front ends. This paper presents a neural recording chopper amplifier capable of handling in-band 80-mVpp differential artifacts and 650-mVpp CM artifacts while preserving the accompanying small neural signals. New techniques have been proposed that introduce immunity to CM interference, increase the input impedance of the chopper amplifier to 1.6 GQ, and increase the maximum realizable resistance of dutycycled resistors (DCR) to 90 GQ. These techniques enable our recording front-end to achieve a dynamic range of 74 dB (200 Hz- 5 kHz) and 81 dB (1-200 Hz). Implemented in a 40-nm CMOS process, the prototype occupies an area of 0.069 mm2/channel, and consumes 2.8 μW from a 1.2-V supply. The input-referred noise is 5.3 μVrms (200 Hz-5 kHz) and 1.8 μVrms (1-200Hz). The total harmonic distortion for a 40-mVp input at 1 kHz is -76 dB. This work improves the input impedance by 5.3× for chopped front-ends, linear-input range by 2×, maximum resistance of DCR by 32×, and tolerance to CM interferers by 6.5×, while maintaining comparable power and noise performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Subthalamic nucleus stimulation in severe obsessive-compulsive disorder
Mallet, L., Polosan, M., Jaafari, N., Baup, N., Welter, M.-L., Fontaine, D., Montcel, S. T. D., Yelnik, J., Chéreau, I., Arbus, C., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708514 · Cited by 965
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237 · cited 11×
“(c) Auxiliary-path technique proposed in [31].”
BackgroundMethodResultInfluentialSelf-citationSuicide after successful deep brain stimulation for movement disorders
Burkhard, P. R., Vingerhoets, F. J. G., Berney, A., Bogousslavsky, J., Villemure, J.-G., & Ghika, J. (2004) · Neurology · doi:10.1212/01.wnl.0000145603.48221.b5 · Cited by 219 · cited 1×
“Open-loop stimulation, though useful, can have detrimental side effects [7], [8] while losing its efficacy over time due to plasticity and other changes in the brain.”
BackgroundEnergy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165 · cited 2×
“reported in [14], [23], and [24] that use “pseudo-resistors” as large resistors to realize sub-hertz high-pass corners.”
Background
Cited by
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
Uehlin, J. P., Smith, W. A., Pamula, V. R., Pepin, E. P., Perlmutter, S., Sathe, V., & Rudell, J. C. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991524 · Cited by 81
Jeon, H., Bang, J.-S., Jung, Y., Choi, I., & Je, M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2930903 · Cited by 62
Huang, C.-W., Lai, C.-K., Hung, C.-C., Wu, C.-Y., & Ker, M.-D. (2023) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2023.3254891 · Cited by 16
Metadata
- Authors
- Chandrakumar, H., & Markovic, D.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2017
- Pages
- 1-18
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2765737812
- Cited by
- 187
- References
- 11
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.