Fully Immersible Subcortical Neural Probes With Modular Architecture and a Delta-Sigma ADC Integrated Under Each Electrode for Parallel Readout of 144 Recording Sites
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper presents a needle-shaped neural probe which integrates an incremental$\Delta \Sigma $-ADC under each electrode in an area of$70\times 70\,\,\mu \text{m}^{\mathrm{ 2}}$. The modular architecture avoids global routing of noise sensitive neural signals and connects with a digital four-wire interface. The re-configurable 5.6/11.5 mm needle enables parallel readout of all 64/144 integrated recording sites and features a constant width and thickness of$70\times 50\,\,\mu \text{m}^{\mathrm{ 2}}$from top to bottom allowing to be fully implanted for deep brain monitoring applications. Platinum or iridium-oxide electrodes can be deposited in a custom post-CMOS process. The functionality of the recording system is demonstrated in anin vivosetup. The noise performance of 6.02$\mu \text{V}_{\text {rms}}$for LFP signals (1–300 Hz) and 10.46$\mu \text{V}_{\text {rms}}$for AP signals (300 Hz–10 kHz) is obtained at a power consumption of 39.14$\mu \text{W}$per recording site.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Analog-to-digital converter survey and analysis
Walden, R. H. (1999) · IEEE Journal on Selected Areas in Communications · doi:10.1109/49.761034 · Cited by 2,186
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · cited 1×
“[21], [23]–[28].”
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231 · cited 1×
“In order to reduce the length of the external routing of the sensitive neuronal signals and thus minimize signal disturbances, headstage designs have been proposed which can be mounted in closest proximity to the probe base [9], [20]–[22].”
BackgroundPothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046006 · Cited by 56
Self-citation
Cited by
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“Other variations of dc-coupled amplifiers use autozeroing techniques in stand-alone amplifiers before digitization [39] or dynamically adjust the reference potential of the neural-analog-to-digital converter (ADC) (ADC-direct without a stand-alone amplifier) by an external control loop [40] to reject the EDO.”
MethodChallenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
Xu, J., Nguyen, A. T., Wu, T., Zhao, W., Luu, D. K., & Yang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2972013 · Cited by 29
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Metadata
- Authors
- De Dorigo, D., Moranz, C., Graf, H., Marx, M., Wendler, D., Shui, B., Sayed Herbawi, A., Kuhl, M., Ruther, P., Paul, O., & Manoli, Y.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2018-11
- Volume
- 53
- Issue
- 11
- Pages
- 3111-3125
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2896455324
- Cited by
- 93
- References
- 9
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Immersible Subcortical Neural Probes With Modular Architecture and a Delta-Sigma ADC Integrated Under Each Electrode for Parallel Readout of 144 Recording Sites. https://app.cochat.ai/papers/10.1109/jssc.2018.2873180
- The paper
- De Dorigo, D., Moranz, C., Graf, H., Marx, M., Wendler, D., Shui, B., Sayed Herbawi, A., Kuhl, M., Ruther, P., Paul, O., & Manoli, Y. (2018). Fully Immersible Subcortical Neural Probes With Modular Architecture and a Delta-Sigma ADC Integrated Under Each Electrode for Parallel Readout of 144 Recording Sites. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2018.2873180
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.