Characterization of Upper-Limb Pathological Tremors: Application to Design of an Augmented Haptic Rehabilitation System
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
In this paper, an adaptive filtering technique is proposed to estimate and characterize pathological tremors caused by Parkinson's Disease (PD) and Essential Tremor (ET). The technique is based on the formulation of band-limited multiple Fourier Linear Combiners (BMFLC) and is called Enhanced-BMFLC (E-BMFLC). The effectiveness of the designed filter is statistically evaluated through a clinical study involving 14 PD and 13 ET patients. The hand tremors of the participants are studied in three Degrees Of Freedom (DOF). Using statistical analysis, it is shown that the new design of the filter significantly enhances the accuracy in comparison with the performance of conventional BMFLC filtering. In addition, E-BMFLC significantly reduces the sensitivity to parameter tuning and intrapatient variabilities. The observed improvements are achieved by modulating the memory of the proposed filter, and by enriching the utilized harmonic model. The proposed filter is then used to develop a safe haptics-enabled robotic rehabilitation architecture, designed for patients having hand tremors. The architecture is entitled Augmented Haptic Rehabilitation (AHR), which enables adaptive management of the involuntary components of the hand motion while delivering assist-as-needed haptic therapy (for the voluntary component) and avoiding unsafe amplification of hand tremors. Experimental evaluations are provided to evaluate the efficacy of the proposed AHR system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite the crucial need for PHT elimination techniques and the numerous research advancements on this topic51–55, including our previous work13,14, there is an unmet need for a reliable, adaptable, and generalizable processing framework that can be directly translated to clinical settings for estimation, extraction, and prediction of action tremor with high spectrotemporal resolution.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [13]
In the citing paper
“Existing methods including EBMFLC and WAKE, share a similar characteristic by assuming that the spectral contents of voluntary and involuntary components are distinct and one could be derived by removing the other from the measurement signal.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [13]
In the citing paper
“It is worth noting that phase lag (even in the order of 10 ms) can easily make a high-gain rehabilitation robot unstable which can sacrifice safety13,56–59.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [13]
In the citing paper
“While the FLC-based methods, e.g., BMFLC and EBMFLC, are focused on modeling the spectral contents of the measurement signal with a linear combination of spectral components, the WAKE method employs spectrotemporal techniques and Kalman filtering to decompose the measurement signal into the two components of motion.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [13]
Citations
Cites
Epidemiology and etiology of Parkinson's disease: a review of the evidence
Wirdefeldt, K., Adami, H.-O., Cole, P., Trichopoulos, D., & Mandel, J. (2011) · European Journal of Epidemiology · doi:10.1007/s10654-011-9581-6 · Cited by 1,199
Stochastic stability of the discrete-time extended Kalman filter
Reif, K., Gunther, S., Yaz, E., & Unbehauen, R. (1999) · IEEE Transactions on Automatic Control · doi:10.1109/9.754809 · Cited by 1,011
Exercise-enhanced neuroplasticity targeting motor and cognitive circuitry in Parkinson's disease
Petzinger, G. M., Fisher, B. E., McEwen, S., Beeler, J. A., Walsh, J. P., & Jakowec, M. W. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70123-6 · Cited by 798
Time-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260
Exploring the relationship between essential tremor and Parkinson's disease
Shahed, J., & Jankovic, J. (2007) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2006.05.033 · Cited by 218
Robust Kalman filters for linear time-varying systems with stochastic parametric uncertainties
Wang, F., & Balakrishnan, V. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/78.992124 · Cited by 202
Frazzitta, G., Maestri, R., Bertotti, G., Riboldazzi, G., Boveri, N., Perini, M., Uccellini, D., Turla, M., Comi, C., Pezzoli, G., et al. (2015) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968314542981 · Cited by 184
Cited by
Abdi, E., Kulić, D., & Croft, E. A. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2987603 · Cited by 72
A Heterogeneous Sensing Suite for Multisymptom Quantification of Parkinson’s Disease
Huo, W., Angeles, P., Tai, Y., Pavese, N., Wilson, S., Hu, M. T., & Vaidyanathan, R. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2978197 · Cited by 84
Review of Advanced Medical Telerobots
Mehrdad, S., Liu, F., Pham, M. T., Lelevé, A., & Atashzar, S. F. (2020) · Applied Sciences · doi:10.3390/app11010209 · Cited by 67
Self-citationAtashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916689139 · Cited by 41
Self-citationAtashzar, S. F., Shahbazi, M., & Patel, R. V. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.03.002 · Cited by 42
Self-citationShahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“Existing methods including EBMFLC and WAKE, share a similar characteristic by assuming that the spectral contents of voluntary and involuntary components are distinct and one could be derived by removing the other from the measurement signal.”
BackgroundInfluentialSelf-citationShahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.007 · Cited by 29
Self-citationReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Ibrahim, A. H., Zhou, Y., Jenkins, M. E., Trejos, A. L., & Naish, M. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3097007 · Cited by 34
Menguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Tremor-Active Controller for Dielectric Elastomer-Based Pathological Tremor Suppression
Kelley, C. R., & Kauffman, J. L. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2972884 · Cited by 26
Haptic Stimulation Glove for Fine Motor Rehabilitation in Virtual Reality Environments
Borja, E. F., Lara, D. A., Quevedo, W. X., & Andaluz, V. H. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-95282-6_16 · Cited by 23
RoboFiSense: Attention-Based Robotic Arm Activity Recognition With WiFi Sensing
Zandi, R., Behzad, K., Motamedi, E., Salehinejad, H., & Siami, M. (2024) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2024.3416851 · Cited by 28
Upper limb intention tremor assessment: opportunities and challenges in wearable technology
Paredes-Acuña, N., Utpadel-Fischler, D., Ding, K., Thakor, N. V., & Cheng, G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01302-9 · Cited by 27
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Self-citationFeizi, N., Patel, R. V., Kermani, M. R., & Atashzar, S. F. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3158195 · Cited by 16
Self-citationReal time estimation and suppression of hand tremor for surgical robotic applications
Kumar, A., Kumar, S., Kaushik, A. K., Kumar, A., & Saini, J. S. (2020) · Microsystem Technologies · doi:10.1007/s00542-019-04736-1 · Cited by 17
Energetic Passivity Decoding of Human Hip Joint for Physical Human-Robot Interaction
Atashzar, S. F., Huang, H.-Y., Duca, F. D., Burdet, E., & Farina, D. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3010459 · Cited by 15
Self-citationExploring dielectric elastomers as actuators for hand tremor suppression
Kelley, C. R., & Kauffman, J. L. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2258735 · Cited by 11
Zhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
Haptic-Enhanced Mixed Reality for Upper Limb Rehabilitation in Parkinson’s Disease
Mahmood, N., Anello, A. E., Kim, J. W., Kim, K., Smith, B. E., & Ridgel, A. L. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782637 · Cited by 9
Dynamic estimation strategy for E-BMFLC filters in analyzing pathological hand tremors
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308681 · Cited by 8
Self-citationZhou, Y., Daemi, P., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3350769 · Cited by 6
Callari, T. C., Mortimer, M., Moody, L., Seyedmahmoudian, M., Lewis, R., & Horan, B. (2021) · Ergonomics · doi:10.1080/00140139.2021.1977844 · Cited by 7
Mengüç, E. C., & Rezayi, N. (2019) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2019.8806387 · Cited by 6
Tan, G. Y., Bakibillah, A. S. M., Chan, P. Y., Tan, C. P., & Nurzaman, S. G. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.109814 · Cited by 8
Wang, W., Jia, B., Ma, J., Wang, X., & Song, H. (2024) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2666 · Cited by 5
Mahmood, N., Bektic, M., Li, C., Ridgel, A. L., & Kim, K. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3644234 · Cited by 4
Mengüç, E. C. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219889171 · Cited by 4
Shahtalebi, S., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308679 · Cited by 3
Self-citationTime-Domain Passivity-based Controller with an Optimal Two-channel Lawrence Telerobotic Architecture
Feizi, N., Thudi, S., Patel, R. V., & Atashzar, S. F. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561930 · Cited by 3
Self-citationAn Improved Wrist Kinematic Model for Human-Robot InteractionPreprint
Yu, N., & Xu, C. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2002.05790 · Cited by 3
Online learning for vibration suppression in physical robot interaction using power tools
Solak, G., & Ajoudani, A. (2026) · Autonomous Robots · doi:10.1007/s10514-026-10252-9 · Cited by 4
Xiao, F., Zhong, B., Wu, Y., & Wang, Y. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3222299 · Cited by 2
A Novel Approach to Parkinson’s Tremor Suppression: E-BMFLC and LADRC Integration
Qi, P., Yang, J., Dai, Y., Zhang, H., & Tong, J. (2024) · IEEE Access · doi:10.1109/access.2024.3424395 · Cited by 2
Interactive System Using Myoelectric Muscle Sensors for the Strengthening Upper Limbs in Children
López, V. M., Zambrano, P. A., Pilatásig, M., & Silva, F. M. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-95282-6_2 · Cited by 2
Training of Deep Bidirectional Rnns for Hand Motion Filtering Via Multimodal Data Fusion
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip45357.2019.8969080 · Cited by 2
Self-citationKim, T.-Y., & Bae, S.-H. (2017) · KSII Transactions on Internet and Information Systems · doi:10.3837/tiis.2017.12.011 · Cited by 2
Tremor estimation and filtering in robotic-assisted surgery
Jia, B., Wang, W., Tian, X., & Wang, X. (2025) · Cognitive Neurodynamics · doi:10.1007/s11571-025-10387-y · Cited by 1
Ukasi, S., Hajra, S., Kim, H. J., Sriphan, S., Pongampai, S., Charoonsuk, T., & Vittayakorn, N. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71380 · Cited by 1
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Multiple-Model and Reduced-Order Kalman Filtering for Pathological Hand Tremor Extraction
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8462491
Self-citationPatolojik Dinlenme Tremorlerinin Kompleks Düzlemde Adaptif Tahmini
Güvenç, B. Ç., & Mengüç, E. C. (2022) · European Journal of Science and Technology · doi:10.31590/ejosat.1039914
Zheng, Y., Yang, Y., Ma, K., Lin, C., Pei, Y., Lu, M., & Ji, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3563022
Ledingham, D., Macerollo, A., & Pavese, N. (2026) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.1205
Pathological tremor filtering and prediction using RSSA-based RVFL networks
Rasheed, A., Tsai, C., & Veluvolu, K. C. (2026) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2026.111409
Metadata
- Authors
- Atashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V.
- Affiliations
- Western University (CA)
- University of Alberta (CA)
- ORCID
- Venue
- IEEE Journal of Selected Topics in Signal Processing
- Published
- 2016-08
- Volume
- 10
- Issue
- 5
- Pages
- 888-903
- ISSN
- 1932-4553 (ISSN-L)
- 1941-0484
- OpenAlex
- W2344177016
- Semantic Scholar
- e4c7f4b75267a77572f6f6972ef7301c8ec506d7
- Cited by
- 45
- References
- 34
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 6 · 2023: 1 · 2022: 4 · 2021: 4 · 2020: 8 · 2019: 4 · 2018: 5 · 2017: 5
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Selected Topics in Signal Processing (publishedVersion)
- Funders
- Canadian Institutes of Health Research (CIHR)
- Natural Sciences and Engineering Research Council (NSERC)
- Collaborative Health Research Projects (CHRP) (#316170)
- AGE-WELL Network of Centres of Excellence (AW CRP 2015-WP5.3)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Computer Science › Signal Processing › Advanced Adaptive Filtering Techniques
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Keywords
- pathological tremor, Parkinson's disease, essential tremor, adaptive filtering, rehabilitation robotics, hand tremor, degrees of freedom, harmonic model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.