CoChat

Characterization of Upper-Limb Pathological Tremors: Application to Design of an Augmented Haptic Rehabilitation System

Atashzar, Seyed Farokh, Shahbazi, Mahya, Samotus, Olivia, Tavakoli, Mahdi, Jog, Mandar S., Patel, Rajni V. · 2016 · IEEE Journal of Selected Topics in Signal Processing

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

In this paper, an adaptive filtering technique is proposed to estimate and characterize pathological tremors caused by Parkinson's Disease (PD) and Essential Tremor (ET). The technique is based on the formulation of band-limited multiple Fourier Linear Combiners (BMFLC) and is called Enhanced-BMFLC (E-BMFLC). The effectiveness of the designed filter is statistically evaluated through a clinical study involving 14 PD and 13 ET patients. The hand tremors of the participants are studied in three Degrees Of Freedom (DOF). Using statistical analysis, it is shown that the new design of the filter significantly enhances the accuracy in comparison with the performance of conventional BMFLC filtering. In addition, E-BMFLC significantly reduces the sensitivity to parameter tuning and intrapatient variabilities. The observed improvements are achieved by modulating the memory of the proposed filter, and by enriching the utilized harmonic model. The proposed filter is then used to develop a safe haptics-enabled robotic rehabilitation architecture, designed for patients having hand tremors. The architecture is entitled Augmented Haptic Rehabilitation (AHR), which enables adaptive management of the involuntary components of the hand motion while delivering assist-as-needed haptic therapy (for the voluntary component) and avoiding unsafe amplification of hand tremors. Experimental evaluations are provided to evaluate the efficacy of the proposed AHR system.

Overview

Integrity signals

Registry

Crossref · 10.1109/jstsp.2016.2530632

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 45

Metadata

Authors
Atashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V.
Affiliations
  • Western University (CA)
  • University of Alberta (CA)
Venue
IEEE Journal of Selected Topics in Signal Processing
Published
2016-08
Volume
10
Issue
5
Pages
888-903
ISSN
  • 1932-4553 (ISSN-L)
  • 1941-0484
OpenAlex
W2344177016
Cited by
45
References
34
Citations by year
2026: 4 · 2025: 4 · 2024: 6 · 2023: 1 · 2022: 4 · 2021: 4 · 2020: 8 · 2019: 4 · 2018: 5 · 2017: 5
FWCI
2.98
Type
journal article
Language
en
Open access
closed
Locations
IEEE Journal of Selected Topics in Signal Processing (publishedVersion)
Funders
  • Canadian Institutes of Health Research (CIHR)
  • Natural Sciences and Engineering Research Council (NSERC)
  • Collaborative Health Research Projects (CHRP) (#316170)
  • AGE-WELL Network of Centres of Excellence (AW CRP 2015-WP5.3)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Computer Science › Signal Processing › Advanced Adaptive Filtering Techniques
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
Keywords
pathological tremor, Parkinson's disease, essential tremor, adaptive filtering, rehabilitation robotics, hand tremor, degrees of freedom, harmonic model

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.