Control Methods and Objectives for Electronically Coupled Distributed Energy Resources in Microgrids: A Review
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Increased penetration of distributed energy resources into conventional power systems increases control challenges. These can be suitably met by microgrids. This paper examines the architecture of microgrids and reviews their classifications and the literatures discussing their control objectives during islanded mode. It finds the use of microgrids enhancing the conventional power system's grid smartness. It also summarizes microgrid control objectives and their most common problems and solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 10×
“In [110], a hierarchical control approach is simulated, where the primary control regulates the voltage on each DER terminal.”
BackgroundMethodInfluentialControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 10×
“function of the value of their output impedance [41].”
BackgroundMethodInfluentialA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621 · cited 1×
“cessing stages: a) single-stage power-conversion systems [27], [32], [33] and b) two-stage power-conversion systems [24], [34]–[36] (which is the most common configuration for all electronically coupled DER).”
BackgroundModeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 4×
“FPD/VQD Control: VPD/FQB control has been reported in many papers [2], [7], [13], [20], [25], [26], [40], [104], [106], [109], [110], [116].”
BackgroundInfluentialPower electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588 · cited 1×
“cessing stages: a) single-stage power-conversion systems [27], [32], [33] and b) two-stage power-conversion systems [24], [34]–[36] (which is the most common configuration for all electronically coupled DER).”
BackgroundDefining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312 · cited 14×
“, a role that microgrid inverters must now assume [42], [44].”
BackgroundInfluentialLasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865 · cited 4×
“unachievable [42], [44], [105], [108], [131].”
BackgroundMethodInfluentialControl of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Katiraei, F., Iravani, R., Hatziargyriou, N., & Dimeas, A. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918702 · Cited by 1,591 · cited 22×
“Thus, significantly different control in the microgrid is required [7], [13], [26], [27].”
BackgroundMethodInfluentialPower Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578 · cited 6×
“function during islanded mode because there is no dominant source of energy [6]–[8].”
BackgroundInfluentialLopes, J. A. P., Hatziargyriou, N., Mutale, J., Djapic, P., & Jenkins, N. (2007) · Electric Power Systems Research · doi:10.1016/j.epsr.2006.08.016 · Cited by 1,413 · cited 3×
“3) allowing load shedding and automated switching through control algorithms, to shorten outage and power restoration time, and keeping the faulted section of the distribution line isolated until utility crews locate the fault location [4], [14], [15]; 4) allowing to run in either (grid-connected or islanded) mode, ac…”
BackgroundOutput Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221 · cited 2×
“3) Proper design of the output impedance; this can reduce the impact caused by changes in the line impedance [95], [103].”
BackgroundMicro-Grid Autonomous Operation During and Subsequent to Islanding Process
Katiraei, F., Iravani, M. R., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835051 · Cited by 1,150
Smart Distribution: Coupled Microgrids
Lasseter, R. H. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2114630 · Cited by 1,130 · cited 9×
“Thus, significantly different control in the microgrid is required [7], [13], [26], [27].”
BackgroundInfluentialGuerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039 · cited 3×
“Microgrid frequency has been much studied [2], [3], [6]–[8], [11]–[14], [16], [20], [23], [25], [26], [40]– [42], [44], [58], [94], [103], [105], [107], [109], [110], [116],”
BackgroundOperation of a Multiagent System for Microgrid Control
Dimeas, A. L., & Hatziargyriou, N. D. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852060 · Cited by 1,031 · cited 2×
“Some authors [6], [39] call the supervisory control architecture a multiagent controller.”
BackgroundGuerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965 · cited 1×
“[16], [44], [94], [96], [104], [116], [117], [120], [128], [129].”
A review on distributed energy resources and MicroGrid
Jiayi, H., Chuanwen, J., & Rong, X. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.06.004 · Cited by 882 · cited 1×
“the MGCC, whereas in a decentralized operation, they make decisions locally [6], [27], [28].”
BackgroundAutonomous control of microgrids
Piagi, P., & Lasseter, R. H. (2006) · 2006 IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2006.1708993 · Cited by 830 · cited 9×
“(VQD) control strategy is one of the most famous and important strategies used to control voltage during islanded mode [2],”
BackgroundInfluentialControl Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788 · cited 10×
“ondary control (MGCC) is responsible for LS [6], [104], [110], [114], [119].”
BackgroundMethodInfluentialOptions for Control of Reactive Power by Distributed Photovoltaic Generators
Turitsyn, K., Sulc, P., Backhaus, S., & Chertkov, M. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2116750 · Cited by 774
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733 · cited 3×
“networks affects accuracy of LS [27], [42], [44], [96], [103], [105], [131].”
BackgroundDesign, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723 · cited 4×
“Nested Control Loops: The term refers to two control loops [22], [56], [119]: inner and outer.”
BackgroundInfluentialControl of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700 · cited 3×
“reliability and expandability, although they enable good VR and accurate current sharing [71], [72].”
BackgroundSmall-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
Voltage rise: the big issue when connecting embedded generation to long 11 kV overhead lines
Masters, C. L. (2002) · Power Engineering Journal · doi:10.1049/pe:20020101 · Cited by 648
Kroposki, B., Lasseter, R., Ise, T., Morozumi, S., Papathanassiou, S., & Hatziargyriou, N. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918718 · Cited by 641 · cited 5×
“[13], [20], [23], [27], [42], [104], [110], [122].”
BackgroundInfluentialDistributed Reactive Power Generation Control for Voltage Rise Mitigation in Distribution Networks
Carvalho, P. M. S., Correia, P. F., & Ferreira, L. A. F. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.919203 · Cited by 607 · cited 2×
“the DERs or upon their sudden tripping) [6], [9]–[11].”
BackgroundControl and Power Management of Converter Fed Microgrids
Sao, C. K., & Lehn, P. W. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.922232 · Cited by 490
Control of Distributed Generation Systems— Part II: Load Sharing Control
Marwali, M. N., Jung, J.-W., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836634 · Cited by 438 · cited 1×
“[72], [138]–[140] The use of VQD is avoided and the line-impedance effect eliminated.”
Recent developments in microgrids and example cases around the world—A review
Ustun, T. S., Ozansoy, C., & Zayegh, A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.033 · Cited by 415 · cited 10×
“Thus, significantly different control in the microgrid is required [7], [13], [26], [27].”
BackgroundMethodInfluentialDistributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid
Chakraborty, S., Weiss, M. D., & Simoes, M. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888766 · Cited by 413 · cited 1×
“microgrid [29], high-frequency ac microgrid [30], [31] (which is used to solve power-quality problems caused by”
BackgroundCentralized control for optimizing microgrids operation
Tsikalakis, A. G., & Hatziargyriou, N. D. (2011) · 2011 IEEE Power and Energy Society General Meeting · doi:10.1109/pes.2011.6039737 · Cited by 365 · cited 1×
“4) In terms of supervisory control, they can be either centralized or decentralized [27]; in centralized control, the central controller in the microgrid sends the required set points to the LC through a two-way communication link, but the technique has low reliability and is redundant [37]; the decentralized techniqu…”
BackgroundAutonomous Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid
Savaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185914 · Cited by 347
High-Quality Power Generation Through Distributed Control of a Power Park Microgrid
Prodanovic, M., & Green, T. C. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882019 · Cited by 341 · cited 18×
“In a centralized operation, they receive set points from the MGCC, whereas in a decentralized operation, they make decisions locally [6], [27], [28].”
BackgroundInfluentialOptimal placement and sizing of a DG based on a new power stability index and line losses
Aman, M. M., Jasmon, G. B., Mokhlis, H., & Bakar, A. H. A. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.05.053 · Cited by 329 · cited 2×
“Voltage stability in islanded mode has been much studied [2], [5]–[7], [13], [16], [20]–[22], [27], [41], [42], [44], [56], [58], [104], [106], [107], [110], [116]–[123].”
BackgroundParallel operation of single phase inverter modules with no control interconnections
Tuladhar, A., Jin, H., Unger, T., & Mauch, K. (2002) · Proceedings of APEC 97 - Applied Power Electronics Conference · doi:10.1109/apec.1997.581439 · Cited by 315 · cited 4×
“LS [72], [75], [77], [84], [133]–[135].”
BackgroundMethodInfluentialControl techniques of Dispersed Generators to improve the continuity of electricity supply
Barsali, S., Ceraolo, M., Pelacchi, P., & Poli, D. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985115 · Cited by 306
Using Low Voltage MicroGrids for Service Restoration
Moreira, C. L., Resende, F. O., & Lopes, J. A. P. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888989 · Cited by 290 · cited 10×
“, a role that microgrid inverters must now assume [42], [44].”
BackgroundInfluentialDecentralized Parallel Operation of Inverters Sharing Unbalanced and Nonlinear Loads
De, D., & Ramanarayanan, V. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2068313 · Cited by 276
3C strategy for inverters in parallel operation achieving an equal current distribution
Wu, T.-F., Chen, Y.-K., & Huang, Y.-H. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.836342 · Cited by 269 · cited 1×
“(ALS) [61]–[68], current limitation control [69], and circular chain control (3C) [69], [70].”
BackgroundSun, X., Lee, Y.-S., & Xu, D. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810867 · Cited by 259
Alcala, J. M., Castilla, M., de Vicuña, L. G., Miret, J., & Vasquez, J. C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2082003 · Cited by 257
A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters
Cheng, P.-T., Chen, C.-A., Lee, T.-L., & Kuo, S.-Y. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2013601 · Cited by 253
Ahn, S.-J., Park, J.-W., Chung, I.-Y., Moon, S.-I., Kang, S.-H., & Nam, S.-R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2047736 · Cited by 252 · cited 5×
“because the demand has to be the same as the supply instantaneously [12], [25], [109].”
BackgroundInfluentialUninterruptible power supply systems provide protection
Guerrero, J. M., Garcia De Vicuna, L., & Uceda, J. (2007) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2007.357184 · Cited by 203 · cited 1×
“The control schemes are classified according to their control-wire interconnections [27], [46].”
BackgroundKakigano, H., Miura, Y., Ise, T., & Uchida, R. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712250 · Cited by 202 · cited 1×
“Other, virtual reactors and resistors [18], [137] have been included into the droop method, with the additional purpose of sharing”
MethodSerban, E., & Serban, H. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050006 · Cited by 201 · cited 17×
“The minimum and maximum ranges of the frequency [16] are 48–51 Hz and 59.”
BackgroundMethodInfluentialA Review of Power Electronics Based Microgrids
Wang, X., Guerrero, J. M., Blaabjerg, F., & Chen, Z. (2012) · Journal of Power Electronics · doi:10.6113/jpe.2012.12.1.181 · Cited by 175 · cited 10×
“Thus, significantly different control in the microgrid is required [7], [13], [26], [27].”
BackgroundMethodInfluentialImpact of Distributed Generations With Energy Storage Devices on the Electric Grid
Srivastava, A. K., Kumar, A. A., & Schulz, N. N. (2012) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2163013 · Cited by 175
Management of microgrids in market environment
Hatziargyriou, N. D., Dimeas, A., Tsikalakis, A. G., Lopes, J. A. P., Karniotakis, G., & Oyarzabal, J. (2005) · 2005 International Conference on Future Power Systems · doi:10.1109/fps.2005.204225 · Cited by 164 · cited 3×
“is responsible for keeping the voltage at the PCC between the specific limits [4], [6], [7], [23], [26], [27], [42], [44], [111].”
BackgroundApplicability of droops in low voltage grids
Engler, A. (2006) · Fraunhofer-Publica (Fraunhofer-Gesellschaft) · doi:10.24406/publica-fhg-353843 · Cited by 144
Auto-master-slave control technique of parallel inverters in distributed AC power systems and UPS
Pei, Y., Jiang, G., Xu, Y., & Wang, Z. (2004) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2004.1355433 · Cited by 143
Location and Sizing of Distributed Generation Units for Loadabilty Enhancement in Primary Feeder
Hien, N. C., Mithulananthan, N., & Bansal, R. C. (2013) · IEEE Systems Journal · doi:10.1109/jsyst.2012.2234396 · Cited by 140 · cited 1×
“[13], [20], [23], [27], [42], [104], [110], [122].”
Inoue, S., & Akagi, H. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711782 · Cited by 137
Silva, M., Morais, H. G. V., & Vale, Z. (2012) · Energy Conversion and Management · doi:10.1016/j.enconman.2012.04.021 · Cited by 133 · cited 1×
“3) allowing load shedding and automated switching through control algorithms, to shorten outage and power restoration time, and keeping the faulted section of the distribution line isolated until utility crews locate the fault location [4], [14], [15]; 4) allowing to run in either (grid-connected or islanded) mode, ac…”
BackgroundColet-Subirachs, A., Ruiz-Álvarez, A., Gomis‐Bellmunt, O., Figuerola, F. A.-C., & Sudrià‐Andreu, A. (2011) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2162924 · Cited by 77 · cited 2×
“ondary control (MGCC) is responsible for LS [6], [104], [110], [114], [119].”
BackgroundSecondary Load-Frequency Control for MicroGrids in Islanded Operation.
Madureira, A., Moreira, C., & Lopes, J. P. (2017) · Renewable Energy and Power Quality Journal · doi:10.24084/repqj03.335 · Cited by 75 · cited 1×
“and a convenient secondary load-frequency control must be considered to maintain the frequency between the specified limits and to run the DER economically [17], [42], [45].”
BackgroundParallel operation of inverters for distributed photovoltaic power supply system
Hua, C., Liao, K.-A., & Lin, J.-R. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/psec.2002.1023104 · Cited by 66 · cited 1×
“LS [72], [75], [77], [84], [133]–[135].”
A review of recent development in smart grid and micro-grid laboratories
Shamshiri, M., Gan, C. K., & Tan, C. W. (2012) · IEEE International Power Engineering and Optimization Conference · doi:10.1109/peoco.2012.6230891 · Cited by 61 · cited 3×
“3) allowing load shedding and automated switching through control algorithms, to shorten outage and power restoration time, and keeping the faulted section of the distribution line isolated until utility crews locate the fault location [4], [14], [15]; 4) allowing to run in either (grid-connected or islanded) mode, ac…”
BackgroundCurrent limitation control technique for parallel operation of UPS inverters
Chiang, S. J., Lin, C. H., & Yen, C. Y. (2005) · PESC record · doi:10.1109/pesc.2004.1355411 · Cited by 44 · cited 1×
“(ALS) [61]–[68], current limitation control [69], and circular chain control (3C) [69], [70].”
Background
Cited by
Microgrids energy management systems: A critical review on methods, solutions, and prospects
Zia, M. F., Elbouchikhi, E., & Benbouzid, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.103 · Cited by 1,005
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Inertia response and frequency control techniques for renewable energy sources: A review
Dreidy, M., Mokhlis, H., & Mekhilef, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.170 · Cited by 853
Microgrids: A review, outstanding issues and future trends
Uddin, M., Mo, H., Dong, D., Elsawah, S., Zhu, J., & Guerrero, J. M. (2023) · Energy Strategy Reviews · doi:10.1016/j.esr.2023.101127 · Cited by 455
Distributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Metadata
- Authors
- Eid, B. M., Rahim, N. A., Selvaraj, J., & Elkhateb, A.
- Venue
- IEEE Systems Journal
- Published
- 2016-06
- Volume
- 10
- Issue
- 2
- Pages
- 446-458
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2332879323
- Cited by
- 188
- References
- 63
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.