Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Neurologic injuries, such as stroke, spinal cord injuries, and weaknesses of skeletal muscles with elderly people, may considerably limit the ability of this population to achieve the main daily living activities. Recently, there has been an increasing interest in the development of wearable devices, the so-called exoskeletons, to assist elderly as well as patients with limb pathologies, for movement assistance and rehabilitation. In this paper, we review and discuss the state of the art of the lower limb exoskeletons that are mainly used for physical movement assistance and rehabilitation. An overview of the commonly used actuation systems is presented. According to different case studies, a classification and comparison between different types of actuators is conducted, such as hydraulic actuators, electrical motors, series elastic actuators, and artificial pneumatic muscles. Additionally, the mainly used control strategies in lower limb exoskeletons are classified and reviewed, based on three types of human-robot interfaces: the signals collected from the human body, the interaction forces between the exoskeleton and the wearer, and the signals collected from exoskeletons. Furthermore, the performances of several typical lower limb exoskeletons are discussed, and some assessment methods and performance criteria are reviewed. Finally, a discussion of the major advances that have been made, some research directions, and future challenges are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“of different electrical activities generated by different cortical areas, and the balance between the training time and accuracy [68], [73].”
BackgroundArtificial Muscles from Fishing Line and Sewing Thread
Haines, C. S., Lima, M. D., Li, N., Spinks, G. M., Foroughi, J., Madden, J. D. W., Kim, S. H., Fang, S., Jung de Andrade, M., Göktepe, F., et al. (2014) · Science · doi:10.1126/science.1246906 · Cited by 1,350
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170 · cited 2×
“, high ratio of actuator power to actuator weight)” [11], [28].”
BackgroundAdaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 1×
“project, EEG signals are used to discrete commands, such as the intended action [71], [72], while EMG signals are also used for controlling the lower limb exoskeleton.”
MethodDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
Cited by
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A Survey of Robots in Healthcare
Kyrarini, M., Lygerakis, F., Rajavenkatanarayanan, A., Sevastopoulos, C., Nambiappan, H. R., Chaitanya, K. K., Babu, A. R., Mathew, J., & Makedon, F. (2021) · Technologies · doi:10.3390/technologies9010008 · Cited by 384
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
Rupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., & Virk, G. S. (2017) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881417743554 · Cited by 228
Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Self-citationPolymer Optical Fiber Sensors in Healthcare Applications: A Comprehensive Review
Leal-Junior, A. G., Diaz, C. A. R., Avellar, L. M., Pontes, M. J., Marques, C., & Frizera, A. (2019) · Sensors · doi:10.3390/s19143156 · Cited by 211
“The population ageing also results in an increase of clinical conditions that affect the human locomotion such as stroke, spinal cord injury, Parkinson’s disease, and weakness of the skeletal muscles [19].”
BackgroundFlexible Actuators for Soft Robotics
Yang, Y., Wu, Y., Li, C., Yang, X., & Chen, W. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900077 · Cited by 192
Ao, D., Song, R., & Gao, J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2583464 · Cited by 166
EEG-Based Control for Upper and Lower Limb Exoskeletons and Prostheses: A Systematic Review
AL-Quraishi, M. S., Elamvazuthi, I., Daud, S. A., Parasuraman, S., & Borboni, A. (2018) · Sensors · doi:10.3390/s18103342 · Cited by 164
“Background Finally, the sixth section presents a discussion of the review and its conclusion.”
BackgroundElectro-pneumatic pumps for soft robotics
Diteesawat, R. S., Helps, T., Taghavi, M., & Rossiter, J. (2021) · Science Robotics · doi:10.1126/scirobotics.abc3721 · Cited by 163
GAVRe2: Towards Data-Driven Upper-Limb Rehabilitation with Adaptive-Feedback Gamification
Lai, Y., Sutjipto, S., Clout, M. D., Carmichael, M. G., & Paul, G. (2018) · 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2018.8665105 · Cited by 13
“This has led to several system with similar implementations and designs [12].”
MethodPerception of Society’s Trust in Care Robots by Public Opinion Leaders
Hoppe, J. A., Melkas, H., Pekkarinen, S., Tuisku, O., Hennala, L., Johansson-Pajala, R.-M., Gustafsson, C., & Thommes, K. (2023) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2022.2081283 · Cited by 7
“Rehabilitation robots are also designed to facilitate tasks at home, for instance, lifting and transporting objects (Huo et al., 2016).”
Background
Metadata
- Authors
- Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y.
- Venue
- IEEE Systems Journal
- Published
- 2016-09
- Volume
- 10
- Issue
- 3
- Pages
- 1068-1081
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2326141327
- Cited by
- 455
- References
- 78
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.