Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Neurologic injuries, such as stroke, spinal cord injuries, and weaknesses of skeletal muscles with elderly people, may considerably limit the ability of this population to achieve the main daily living activities. Recently, there has been an increasing interest in the development of wearable devices, the so-called exoskeletons, to assist elderly as well as patients with limb pathologies, for movement assistance and rehabilitation. In this paper, we review and discuss the state of the art of the lower limb exoskeletons that are mainly used for physical movement assistance and rehabilitation. An overview of the commonly used actuation systems is presented. According to different case studies, a classification and comparison between different types of actuators is conducted, such as hydraulic actuators, electrical motors, series elastic actuators, and artificial pneumatic muscles. Additionally, the mainly used control strategies in lower limb exoskeletons are classified and reviewed, based on three types of human-robot interfaces: the signals collected from the human body, the interaction forces between the exoskeleton and the wearer, and the signals collected from exoskeletons. Furthermore, the performances of several typical lower limb exoskeletons are discussed, and some assessment methods and performance criteria are reviewed. Finally, a discussion of the major advances that have been made, some research directions, and future challenges are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“of different electrical activities generated by different cortical areas, and the balance between the training time and accuracy [68], [73].”
BackgroundArtificial Muscles from Fishing Line and Sewing Thread
Haines, C. S., Lima, M. D., Li, N., Spinks, G. M., Foroughi, J., Madden, J. D. W., Kim, S. H., Fang, S., Jung de Andrade, M., Göktepe, F., et al. (2014) · Science · doi:10.1126/science.1246906 · Cited by 1,350
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170 · cited 2×
“, high ratio of actuator power to actuator weight)” [11], [28].”
BackgroundAdaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 1×
“project, EEG signals are used to discrete commands, such as the intended action [71], [72], while EMG signals are also used for controlling the lower limb exoskeleton.”
MethodDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“project, EEG signals are used to discrete commands, such as the intended action [71], [72], while EMG signals are also used for controlling the lower limb exoskeleton.”
MethodDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Wearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 520
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474 · cited 11×
“It should also be noted that the endurance of the wearers could not be improved significantly using HAL-5.”
MethodInfluentialVeneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 1×
“[48] developed a series elastic and Bowden-cable-based ac-”
BackgroundHusemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
Wearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Power assist method for HAL-3 using EMG-based feedback controller
Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y. (2004) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244649 · Cited by 392
Power assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381
Treatment Interventions for the Paretic Upper Limb of Stroke Survivors: A Critical Review
Barreca, S., Wolf, S. L., Fasoli, S., & Bohannon, R. (2003) · Neurorehabilitation and Neural Repair · doi:10.1177/0888439003259415 · Cited by 378
Static and dynamic characteristics of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.350977 · Cited by 351
Power Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
Series elastic actuators for high fidelity force control
Pratt, J., Krupp, B., & Morse, C. (2002) · Industrial Robot: An International Journal · doi:10.1108/01439910210425522 · Cited by 343
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Weakness in Patients With Hemiparesis
Bourbonnais, D., & Noven, S. V. (1989) · American Journal of Occupational Therapy · doi:10.5014/ajot.43.5.313 · Cited by 332
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
The Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
Concurrent neuromechanical and functional gains following upper-extremity power training post-stroke
Patten, C., Condliffe, E. G., Dairaghi, C. A., & Lum, P. S. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-1 · Cited by 259
On the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 1×
“demanding labor [27]–[29].”
Griffin, T. M., Roberts, T. J., & Kram, R. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00944.2002 · Cited by 251
The rise of the body bots [robotic exoskeletons
Guizzo, E., & Goldstein, H. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1515961 · Cited by 238
Detection of self-paced reaching movement intention from EEG signals
Lew, E. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00013 · Cited by 227
Rehabilitation Exoskeletal Robotics
Pons, J. L. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936548 · Cited by 222
Development of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
Recent trends in assistive technology for mobility
Cowan, R. E., Fregly, B. J., Boninger, M. L., Chan, L., Rodgers, M. M., & Reinkensmeyer, D. J. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-20 · Cited by 194
Brain-computer interface controlled robotic gait orthosis
Do, A. H., Wang, P. T., King, C. E., Chun, S. N., & Nenadic, Z. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-111 · Cited by 189
A PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
Review of hybrid exoskeletons to restore gait following spinal cord injury
del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0043 · Cited by 174
Self-citationDevelopment of power assisting suit for assisting nurse labor
YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.703 · Cited by 169 · cited 2×
“This exoskeleton was developed at Kanagawa Institute of Technology, Atsugi, Japan [33], [34], and was used for assisting a nurse to carry a patient in her arms.”
MethodNovel gait adaptation and neuromotor training results using an active leg exoskeleton
Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2041245 · Cited by 165 · cited 1×
“[76] presented a force field controller to help the patients accomplish the neuromotor gait training.”
BackgroundAn Efficient Robotic Tendon for Gait Assistance
Hollander, K. W., Ilg, R., Sugar, T. G., & Herring, D. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264391 · Cited by 161
Gregorczyk, K. N., Hasselquist, L., Schiffman, J. M., Bensel, C. K., Obusek, J. P., & Gutekunst, D. J. (2010) · Ergonomics · doi:10.1080/00140139.2010.512982 · Cited by 160
Design of an electrically actuated lower extremity exoskeleton
Zoss, A., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394030 · Cited by 160
Leading Edge of Cybernics: Robot Suit HAL
Sankai, Y. (2006) · SICE-ICASE International Joint Conference · doi:10.1109/sice.2006.314982 · Cited by 153
Prosthetics, exoskeletons, and rehabilitation [Grand Challenges of Robotics]
Dellon, B., & Matsuoka, Y. (2007) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2007.339622 · Cited by 150
Application of EMG signals for controlling exoskeleton robots
Fleischer, C., Wege, A., Kondak, K., & Hommel, G. (2006) · Biomedizinische Technik. Biomedical engineering · doi:10.1515/bmt.2006.063 · Cited by 150
Technologies and combination therapies for enhancing movement training for people with a disability
Reinkensmeyer, D. J., & Boninger, M. L. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-17 · Cited by 144
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Predicting the intended motion with EMG signals for an exoskeleton orthosis controller
Fleischer, C., Reinicke, C., & Hommel, G. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545504 · Cited by 134
A Novel Compact Torsional Spring for Series Elastic Actuators for Assistive Wearable Robots
Carpino, G., Accoto, D., Sergi, F., Tagliamonte, N. L., & Guglielmelli, E. (2012) · Journal of Mechanical Design · doi:10.1115/1.4007695 · Cited by 129
Sensing Pressure Distribution on a Lower-Limb Exoskeleton Physical Human-Machine Interface
Rossi, S., Vitiello, N., Lenzi, T., Ronsse, R., Koopman, B., Persichetti, A., Vecchi, F., Ijspeert, A. J., van der Kooij, H., & Carrozza, M. C. (2010) · Sensors · doi:10.3390/s110100207 · Cited by 122
What’s New in Stroke Rehabilitation
Teasell, R. W., & Kalra, L. (2004) · Stroke · doi:10.1161/01.str.0000115937.94104.76 · Cited by 115
An exoskeleton using controlled energy storage and release to aid ankle propulsion
Wiggin, M. B., Sawicki, G. S., & Collins, S. H. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975342 · Cited by 110 · cited 1×
“[43] (they only control the energy storage and release without actuation).”
BackgroundNew horizons for orthotic and prosthetic technology: artificial muscle for ambulation
Herr, H. M., & Kornbluh, R. D. (2004) · SPIE Proceedings · doi:10.1117/12.544510 · Cited by 110
Lower-Limb Movement Assistance through Wearable Robots: State of the Art and Challenges
Mohammed, S., Amirat, Y., & Rifaï, H. (2012) · Advanced Robotics · doi:10.1163/016918611x607356 · Cited by 109
Self-citationStand alone wearable power assisting suit - sensing and control systems
Yamamoto, K., Ishii, M., Noborisaka, H., & Hyodo, K. (2005) · IEEE RO-MAN · doi:10.1109/roman.2004.1374841 · Cited by 106
Needs and solutions - home automation and service robots for the elderly and disabled
Harmo, P., Taipalus, T., Knuuttila, J., Vallet, J., & Halme, A. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545387 · Cited by 98
Contreras-Vidal, J. L., & Grossman, R. G. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609816 · Cited by 97
Predicting Intended Movement Direction Using EEG from Human Posterior Parietal Cortex
Wang, Y., & Makeig, S. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02812-0_52 · Cited by 96
Effects of robotic guidance on the coordination of locomotion
Moreno, J. C., Barroso, F. O., Farina, D., Gizzi, L., Santos, C. P., Molinari, M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-79 · Cited by 86
Self-citationA two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients
Ohta, Y., Yano, H., Suzuki, R., Yoshida, M., Kawashima, N., & Nakazawa, K. (2007) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim55 · Cited by 73
Boehler, A., Hollander, K. W., Sugar, T. G., & Shin, D. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543504 · Cited by 70
Hitt, J. K., Oymagil, A. M., Sugar, T. G., Hollander, K. W., Boehler, A., & Fleeger, J. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363543 · Cited by 67
Development of Power Assisting Suit (Miniaturization of Supply System to Realize Wearable Suit)
YAMAMOTO, K., Ishii, M., HYODO, K., YOSHIMITSU, T., & Matsuo, T. (2003) · JSME International Journal Series C · doi:10.1299/jsmec.46.923 · Cited by 64
Hybrid hydraulic-electric power unit for field and service robots
Amundson, K., Raade, J., Harding, N., & Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545452 · Cited by 55
Development of Externally Powered Lower Limb Orthosis with Bilateral-Servo Actuator
Saito, Y., Kikuchi, K., Negoto, H., et al. (2005) · doi:10.1109/icorr.2005.1501127 · Cited by 55
Previdi, F., Ferrarin, M., Savaresi, S. M., & Bittanti, S. (2004) · Control Engineering Practice · doi:10.1016/j.conengprac.2004.10.007 · Cited by 52
Development of a gait rehabilitation system using a locomotion interface
Yano, H., Kasai, K., Saitou, H., & Iwata, H. (2003) · The Journal of Visualization and Computer Animation · doi:10.1002/vis.321 · Cited by 44
Cooperative walk control of paraplegia patient and assistive system
Hasegawa, Y., Jang, J., & Sankai, Y. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5354192 · Cited by 43
Online Assessment of Human-Robot Interaction for Hybrid Control of Walking
del‐Ama, A. J., Moreno, J. C., Gil-Agudo, A. M., Reyes-Guzmán, A. D. L., & Pons, J. L. (2011) · Sensors · doi:10.3390/s120100215 · Cited by 37
Self-citationBrain controlled robotic exoskeleton for neurorehabilitation
McDaid, A., Song, X., & Xie, S. Q. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584231 · Cited by 32
A Study of a Knee Extension Controlled by a Closed Loop Functional Electrical Stimulation
Schmitt, C., & Métrailler, P. (2004) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 24
Gregorczyk, K. N., Obusek, J. P., Hasselquist, L., Bensel, J. M. S., Carolyn, K., Gutekunst, D. J., & Frykman, P. (2006) · Defense Technical Information Center (DTIC) · Cited by 20
Brain-Computer Interface: Generic Control Interface for Social Interaction Applications
Hintermüller, C., Guger, C., & Edlinger, G. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21501-8_48 · Cited by 8
Cited by
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A Survey of Robots in Healthcare
Kyrarini, M., Lygerakis, F., Rajavenkatanarayanan, A., Sevastopoulos, C., Nambiappan, H. R., Chaitanya, K. K., Babu, A. R., Mathew, J., & Makedon, F. (2021) · Technologies · doi:10.3390/technologies9010008 · Cited by 384
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
Flexible Actuators for Soft Robotics
Yang, Y., Wu, Y., Li, C., Yang, X., & Chen, W. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900077 · Cited by 192
Metadata
- Authors
- Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y.
- Venue
- IEEE Systems Journal
- Published
- 2016-09
- Volume
- 10
- Issue
- 3
- Pages
- 1068-1081
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2326141327
- Cited by
- 455
- References
- 78
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.