Detection of False Data Injection Attacks in Smart Grids Based on Graph Signal Processing
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The smart grid combines the classical power system with the information technology, leading to a cyber-physical system. In such an environment, the malicious injection of data has the potential to cause severe consequences. Classical residual-based methods for bad data detection are unable to detect well designed false data injection (FDI) attacks. Moreover, most of the works on FDI attack detection are based on the linearized DC model of the power system and fails to detect attacks based on the AC model. The aim of this paper is to address these problems by using the graph structure of the grid and the AC power flow model. We derive an attack detection method that is able to detect previously undetectable FDI attacks. This method is based on concepts originating from graph signal processing (GSP). The proposed detection scheme calculates the graph Fourier transform of an estimated grid state and filters the graph's high-frequency components. By comparing the maximum norm of this outcome with a threshold, we can detect the presence of FDI attacks. Case studies on the IEEE 14-bus system demonstrate that the proposed method is able to detect a wide range of previously undetectable attacks, both on angles and on magnitudes of the voltages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
Catastrophic cascade of failures in interdependent networks
Buldyrev, S. V., Parshani, R., Paul, G., Stanley, H. E., & Havlin, S. (2010) · Nature · doi:10.1038/nature08932 · Cited by 4,513 · cited 1×
“In particular, smart grids that combine classical power system components with advanced information and communication technology (ICT) to build a cyber-physical system are considered to be particularly vulnerable, due to (among other reasons) dedicated attacks [3]–[6].”
BackgroundShuman, D. I., Narang, S. K., Frossard, P., Ortega, A., & Vandergheynst, P. (2013) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2235192 · Cited by 4,421 · cited 12×
“In the context of GSP, the operation of (10) is referred to as spectral decomposition of the matrix Y R , the eigenvectors are called the spectral components and the eigenvalues can be interpreted as the graph frequencies [43].”
BackgroundInfluentialAbur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974 · cited 2×
“The PSSE provides the input for multiple monitoring purposes, including security assessment, load forecasting, reliability analysis, and economic considerations [12], [13].”
BackgroundMethodFalse data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428
Graph Signal Processing: Overview, Challenges, and Applications
Ortega, A., Frossard, P., Kovačević, J., Moura, J. M. F., & Vandergheynst, P. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2820126 · Cited by 1,787 · cited 5×
“The definition of ordering of the eigenvalues in this case is a theoretical open question in GSP [39], [40], [43].”
BackgroundMethodInfluentialDiscrete Signal Processing on Graphs
Sandryhaila, A., & Moura, J. M. F. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2238935 · Cited by 1,531 · cited 1×
“In the following, we consider the polynomial graph filters that take the form [52]:”
BackgroundFalse data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285 · cited 2×
“However, it was shown in [19] that if the attacker has sufficient knowledge of the system topology, a well-designed attack can pass the residual-based bad data detector and perturb the PSSE to any desired level.”
BackgroundThurner, L., Scheidler, A., Schafer, F., Menke, J.-H., Dollichon, J., Meier, F., Meinecke, S., & Braun, M. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2829021 · Cited by 1,171
A Review of False Data Injection Attacks Against Modern Power Systems
Liang, G., Zhao, J., Luo, F., Weller, S. R., & Dong, Z. Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2495133 · Cited by 1,028 · cited 1×
“Thus, the impact of FDI attacks could be manifold and range from economic consequences, through overloading and physical damage, to serious human hazard [14]–[16].”
BackgroundDiscrete Signal Processing on Graphs: Frequency Analysis
Sandryhaila, A., & Moura, J. M. F. (2014) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2014.2321121 · Cited by 879 · cited 3×
“1) Maximum Threshold: In [40], the threshold is defined as the maximum from a set of historic states as”
BackgroundMethodMalicious Data Attacks on the Smart Grid
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2163807 · Cited by 784 · cited 8×
“Most of the aforementioned works, notably [27]–[32], [35], rely on the linearized DC model to describe the electrical behavior of the power system.”
BackgroundMethodInfluentialBad data analysis for power system state estimation
Handschin, E., Schweppe, F. C., Kohlas, J., & Fiechter, A. (1975) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/t-pas.1975.31858 · Cited by 676 · cited 1×
“The PSSE is usually equipped with methods to detect random false data and faults that are based on residuals (see [17], [18] and [12, Ch.”
MethodVulnerability Assessment of AC State Estimation With Respect to False Data Injection Cyber-Attacks
Hug, G., & Giampapa, J. A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2195338 · Cited by 595 · cited 2×
“The construction of such an attack on the angle is described in [27], and similarly, the description given in [37] is used to construct an attack on the voltage magnitude.”
BackgroundMethodDetecting Stealthy False Data Injection Using Machine Learning in Smart Grid
Esmalifalak, M., Liu, L., Nguyen, N., Zheng, R., & Han, Z. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2341597 · Cited by 595 · cited 3×
“Other detection methods for undetectable FDI attacks require reliable load forecasts [30] or explore machine learning concepts [32].”
BackgroundDetecting False Data Injection Attacks on Power Grid by Sparse Optimization
Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2284438 · Cited by 446 · cited 2×
“in [31] proposed a method to detect previously unobservable attacks, but their approach is limited to sparse attacks where the measurement devices are only compromised temporarily.”
BackgroundMethodDetecting False Data Injection Attacks in AC State Estimation
Chaojun, G., Jirutitijaroen, P., & Motani, M. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2388545 · Cited by 419 · cited 1×
“Since the construction of an undetectable attack based on the AC model requires that the attacker has far more knowledge and can solve nonconvex optimization problems [11], [27], detection methods for AC model-based FDI attacks have not been extensively studied yet (see [36]).”
BackgroundCritical Infrastructure Protection in Homeland Security: Defending a Networked Nation
Lewis, T. G. (2006) · Wiley eBooks · doi:10.1002/0471789542 · Cited by 330 · cited 1×
“2927469 One of the most critical infrastructures is the power system, as almost all other infrastructures depend on it [2].”
BackgroundSecure Control Systems: A Quantitative Risk Management Approach
(2015) · IEEE Control Systems · doi:10.1109/mcs.2014.2364709 · Cited by 316
Non-Intrusive Load Disaggregation Using Graph Signal Processing
He, K., Stankovic, L., Liao, J., & Stankovic, V. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2598872 · Cited by 306 · cited 1×
“However, GSP has rarely been applied in the context of power systems (see [45], where it is used to disaggregate the total load of one power measurement).”
MethodBlind False Data Injection Attack Using PCA Approximation Method in Smart Grid
Yu, Z.-H., & Chin, W.-L. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2382714 · Cited by 305 · cited 2×
“Most of the aforementioned works, notably [27]–[32], [35], rely on the linearized DC model to describe the electrical behavior of the power system.”
BackgroundMethodOnline Detection of Stealthy False Data Injection Attacks in Power System State Estimation
Ashok, A., Govindarasu, M., & Ajjarapu, V. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2596298 · Cited by 297 · cited 4×
“Other detection methods for undetectable FDI attacks require reliable load forecasts [30] or explore machine learning concepts [32].”
BackgroundMethodInfluentialFalse Data Attacks Against AC State Estimation With Incomplete Network Information
Liu, X., & Li, Z. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2521178 · Cited by 282 · cited 3×
“This test case relies on the constructed undetectable FDI attack proposed in [38].”
BackgroundMethodLiang, J., Sankar, L., & Kosut, O. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2504950 · Cited by 279 · cited 1×
“Thus, the impact of FDI attacks could be manifold and range from economic consequences, through overloading and physical damage, to serious human hazard [14]–[16].”
BackgroundMonitoring and Optimization for Power Grids: A Signal Processing Perspective
Giannakis, G. B., Kekatos, V., Gatsis, N., et al. (2012) · Cited by 264
A Graph Signal Processing Perspective on Functional Brain Imaging
Huang, W., Bolton, T. A. W., Medaglia, J. D., Bassett, D. S., Ribeiro, A., & Van De Ville, D. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2798928 · Cited by 245 · cited 1×
“Previously, GSP has been applied to various fields, such as sensor networks, biological networks, image processing, machine learning, and data science [43], [44].”
MethodMonitoring and Optimization for Power Grids: A Signal Processing Perspective
Giannakis, G. B., Kekatos, V., Gatsis, N., Kim, S.-J., Zhu, H., & Wollenberg, B. F. (2013) · IEEE Signal Processing Magazine · doi:10.1109/msp.2013.2245726 · Cited by 235 · cited 2×
“As the electric characteristic of a line is independent of the direction of the current that goes through it, the graph is assumed to be undirected [13].”
BackgroundStationary Graph Processes and Spectral Estimation
Marques, A. G., Segarra, S., Leus, G., & Ribeiro, A. (2017) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2017.2739099 · Cited by 235
Sparse Malicious False Data Injection Attacks and Defense Mechanisms in Smart Grids
Hao, J., Piechocki, R. J., Kaleshi, D., Chin, W. H., & Fan, Z. (2015) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2015.2475695 · Cited by 233 · cited 1×
“It should be emphasized that while FDI attacks are usually considered to be sparse attacks [27], [31], [50], in the sense that attacks are launched only at a few buses, here, the attack vector c is not necessarily sparse, since it represents the influence of the attack on the PSSE.”
BackgroundHuang, Y., Tang, J., Cheng, Y., Li, H., Campbell, K. A., & Han, Z. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2323266 · Cited by 177 · cited 1×
“, the work in [27] that compares the norms of attacked states against those of unattacked ones, or the work in [28] that proposes an adapted cumulative sum method, but these, too, cannot overcome the model’s inherent limitations in its detection capabilities of such attacks.”
BackgroundApproximating signals supported on graphs
Zhu, X., & Rabbat, M. (2012) · 2012 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2012.6288775 · Cited by 148 · cited 2×
“and the resulting signal FR{v̂} has properties analogous to the Fourier transform of classic signals [43], [51].”
BackgroundPower Grid AC-Based State Estimation: Vulnerability Analysis Against Cyber Attacks
Jin, M., Lavaei, J., & Johansson, K. H. (2018) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2018.2852774 · Cited by 133 · cited 4×
“However, since the DC model is only a simplification of the more realistic and more accurate AC model, this is a significant shortcoming with regard to the vulnerability analysis [11].”
BackgroundMethodInfluentialNetwork-Aware Mitigation of Data Integrity Attacks on Power System State Estimation
Vuković, O., Sou, K. C., Dán, G., & Sandberg, H. (2012) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2012.120709 · Cited by 133 · cited 1×
“Such types of attacks are called undetectable attacks [19] or stealth attacks [25], [26].”
BackgroundAchieving Efficient Detection Against False Data Injection Attacks in Smart Grid
Xu, R., Wang, R., Guan, Z., Wu, L., Wu, J., & Du, X. (2017) · IEEE Access · doi:10.1109/access.2017.2728681 · Cited by 113 · cited 1×
“Finally, in [33] and [34], signals originating from hardware components and from the process level, respectively, are used to detect unobservable FDI attacks, but these solutions are very specific to the hardware and protocols used in the power system.”
MethodPower Grid State Estimation Following a Joint Cyber and Physical Attack
Soltan, S., Yannakakis, M., & Zussman, G. (2016) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2016.2620807 · Cited by 78 · cited 1×
“In particular, smart grids that combine classical power system components with advanced information and communication technology (ICT) to build a cyber-physical system are considered to be particularly vulnerable, due to (among other reasons) dedicated attacks [3]–[6].”
BackgroundExtending Classical Multirate Signal Processing Theory to Graphs—Part I: Fundamentals
Teke, O., & Vaidyanathan, P. P. (2016) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2016.2617833 · Cited by 73
Power Systems Topology and State Estimation by Graph Blind Source Separation
Grotas, S., Yakoby, Y., Gera, I., & Routtenberg, T. (2019) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2019.2901356 · Cited by 73 · cited 1×
“This knowledge about the system topology can be gained by analyzing measurements [20]–[24].”
BackgroundSelf-citationGraph spectral compressed sensing for sensor networks
Zhu, X., & Rabbat, M. (2012) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2012.6288515 · Cited by 62 · cited 2×
“In [54], this equation is used to compress and approximate the signal.”
MethodDetection of False Data Injection Attacks in Power Systems with Graph Fourier Transform
Drayer, E., & Routtenberg, T. (2018) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2018.8646454 · Cited by 57 · cited 2×
“The details and a full algorithm for the DC model case can be found in our preliminary work [46].”
MethodSelf-citationDefense Mechanisms against Data Injection Attacks in Smart Grid Networks
Jiang, J. S., & Qian, Y. (2017) · IEEE Communications Magazine · doi:10.1109/mcom.2017.1700180 · Cited by 51 · cited 4×
“We also implemented an adapted version of the work proposed in [29], which is based on a residual evaluation between the grid states of two consecutive time steps ‖v̂t − v̂t−1‖.”
BackgroundMethodInfluentialPMU-Based Detection of Voltage Imbalances with Tolerance Constraints
Routtenberg, T., Concepcion, R., & Tong, L. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2591727 · Cited by 26 · cited 1×
“methods to cope with physical faults or disturbances in power systems, such as outages [7], off-nominal frequencies [8], and voltage imbalances [9], [10].”
MethodSelf-citationGoing Beyond Cybersecurity Compliance: What Power and Utility Companies Really Need To Consider
Smith, E., Corzine, S., Racey, D., Dunne, P. M., Hassett, C., & Weiss, J. (2016) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2573898 · Cited by 26
Plant-wide fault detection using graph signal processing
Silva, D. R. C., & Ortega, A. (2016) · IEEE Sensor Array and Multichannel Signal Processing Workshop (SAM) · doi:10.1109/sam.2016.7569744 · Cited by 3 · cited 1×
“2) Averaged Threshold: In [53] the threshold is defined as the average of historic states plus a deviation term to set the size of the confidence interval as follows:”
Background
Cited by
Yohanandhan, R. V., Elavarasan, R. M., Manoharan, P., & Mihet-Popa, L. (2020) · IEEE Access · doi:10.1109/access.2020.3016826 · Cited by 391
Metadata
- Authors
- Drayer, E., & Routtenberg, T.
- Venue
- IEEE Systems Journal
- Published
- 2020-06
- Volume
- 14
- Issue
- 2
- Pages
- 1886-1896
- ISSN
- 1932-8184 (ISSN-L)
- 1937-9234
- 2373-7816
- OpenAlex
- W2897230280
- Cited by
- 165
- References
- 43
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.