CoChat

A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients

Kwon, Junghan, Park, Ji-Hong, Ku, Subyeong, Jeong, YeongHyeon, Paik, Nam-Jong, Park, Yong-Lae · 2019 · IEEE Robotics and Automation Letters

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

We propose a soft robotic ankle-foot-orthosis for poststroke patients, which is inexpensive, lightweight, easy to wear, and capable of gait assistance for rehabilitation not only in the clinic but also in daily life. The device includes a 3D-printed flexible brace and an ankle support that allows natural flexion and extension of the ankle but provides support in the vertical direction preventing the structure from buckling. A bi-directional tendon-driven actuator was used for assisting both dorsiflexion and plantarflexion. The device also contains a wearable gait sensing module for measuring the leg trajectory and the foot pressures in real time for feedback control. Since the device is powered by a rechargeable battery and communicates with the main controller wirelessly, it is fully untethered, making it mobile and comfortable. Using the measured sensor data and the biomechanics of the legs, the realtime gait phase is detected, and then a gait assistance algorithm for both dorsiflexion and plantarflexion provides an accurate prediction of a control phase and timing although there are variations in the gait trajectories among individuals. As a feasibility test, the walking experiment was conducted with a post-stroke patient. The result showed improvement in both gait propulsion and foot-drop prevention.

Overview

Integrity signals

Registry

Crossref · 10.1109/lra.2019.2908491

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Cited by

See all 169

Metadata

Authors
Kwon, J., Park, J.-H., Ku, S., Jeong, Y., Paik, N.-J., & Park, Y.-L.
Affiliations
  • Seoul National University (KR)
  • Seoul National University Bundang Hospital (KR)
Venue
IEEE Robotics and Automation Letters
Published
2019-07
Volume
4
Issue
3
Pages
2547-2552
ISSN
  • 2377-3766 (ISSN-L)
  • 2377-3774
OpenAlex
W2925674589
Cited by
158
References
26
Citations by year
2026: 10 · 2025: 19 · 2024: 20 · 2023: 34 · 2022: 30 · 2021: 22 · 2020: 17 · 2019: 5
FWCI
6.53
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Robotics and Automation Letters (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
  • National Research Foundation of Korea (NRF-2016R1A5A1938472)
  • Seoul National University Bundang Hospital Research Fund (14-2017-025)
  • Interdisciplinary Research Initiatives Program (800-20170165)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
ankle-foot orthosis, stroke rehabilitation, gait assistance, tendon-driven actuators, foot pressure sensing, gait phase detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients. https://app.cochat.ai/papers/10.1109/lra.2019.2908491
The paper
Kwon, J., Park, J.-H., Ku, S., Jeong, Y., Paik, N.-J., & Park, Y.-L. (2019). A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients. IEEE Robotics and Automation Letters. https://doi.org/10.1109/lra.2019.2908491

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.