A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
We propose a soft robotic ankle-foot-orthosis for poststroke patients, which is inexpensive, lightweight, easy to wear, and capable of gait assistance for rehabilitation not only in the clinic but also in daily life. The device includes a 3D-printed flexible brace and an ankle support that allows natural flexion and extension of the ankle but provides support in the vertical direction preventing the structure from buckling. A bi-directional tendon-driven actuator was used for assisting both dorsiflexion and plantarflexion. The device also contains a wearable gait sensing module for measuring the leg trajectory and the foot pressures in real time for feedback control. Since the device is powered by a rechargeable battery and communicates with the main controller wirelessly, it is fully untethered, making it mobile and comfortable. Using the measured sensor data and the biomechanics of the legs, the realtime gait phase is detected, and then a gait assistance algorithm for both dorsiflexion and plantarflexion provides an accurate prediction of a control phase and timing although there are variations in the gait trajectories among individuals. As a feasibility test, the walking experiment was conducted with a post-stroke patient. The result showed improvement in both gait propulsion and foot-drop prevention.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Exosuits produce gait-restorative joint torques by transmitting mechanical power from waist-mounted body-worn or off-board actuators to the wearer through the interaction of textile anchors and cable-based transmission (Figure 13D).[494]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [494]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“An experienced operator placed 15 reflective markers to calculate the kinematic data [23].”
MethodGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Design and Fabrication of Soft Artificial Skin Using Embedded Microchannels and Liquid Conductors
Park, Y.-L., Chen, B.-R., & Wood, R. J. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2200790 · Cited by 776
Self-citationA soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672 · cited 1×
“Since it is difficult to estimate the walking state and the control timing with a limited number of sensors, individual tuning of control parameters has been introduced [12].”
BackgroundMulticenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
Self-citationGait and balance disorders in older adults.
Salzman, B. (2010) · PubMed · Cited by 428
Cited by
Items 101–169 of 169
A Two-Degree-of-Freedom Ankle Exoskeleton With Control of Plantarflexion and Inversion–Eversion
Jacobson, M., Kantharaju, P., Vakacherla, S. S., & Kim, M. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3532211 · Cited by 5
Shin, D., Lee, J.-H., Kim, T., & Seok, H. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856468 · Cited by 5
Lara-Velazquez, C. A., Ramirez‐Paredes, J., & González-Sandoval, B. V. (2024) · Applied Sciences · doi:10.3390/app14072726 · Cited by 5
Wang, Z., Chen, C., Yang, F., Chen, H., Du, S., Liu, Y., Wang, X., & Wu, X. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3545899 · Cited by 5
Hong, J.-C., Ohashi, H., & Iwata, H. (2022) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2022.p0121 · Cited by 4
Model-Based Control Strategies Comparison of One Bionic Ankle Tensegrity Exoskeleton: BATE
Wei, D., Mao, S., Zhang, Z., Wei, X., Gao, T., & Ficuciello, F. (2025) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra55743.2025.11127237 · Cited by 4
Soft Actuated Foot Exoskeleton for Ankle Rehabilitation
Kamarudin, N. E. M. (2020) · International Journal of Advanced Trends in Computer Science and Engineering · doi:10.30534/ijatcse/2020/5391.42020 · Cited by 4
Design and manufacturing process of 3D printed ankle-foot orthoses for podiatry
Gupta, S., Mittal, D., Narayan, J., Jhunjhunwala, S., & Dwivedy, S. K. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91911-1.00010-9 · Cited by 3
Liu, Y., Sun, R., Li, Y., Zhang, M., & Zou, K. (2023) · Journal of Bionic Engineering · doi:10.1007/s42235-023-00398-y · Cited by 3
Jayakumar, A., Bermejo-García, J., Jorge, D., Agujetas, R., Romero, F., & Sánchez, F. J. A. (2023) · Actuators · doi:10.3390/act12080309 · Cited by 3
A Twisted Elastic Rotary-Rail Actuator (TERRA) Using a Double-Stranded Helix Structure
Kim, J. I., Choi, J., Kim, J., & Park, Y. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3099098 · Cited by 3
Self-citationDiseño de un estudio experimental para rehabilitación de rodilla con exoesqueleto activo
Duarte, B. (2022) · Repositorio Institucional E-DocUR (Universidad Del Rosario) · doi:10.48713/10336_21014 · Cited by 3
A Wearable Wrist Rehabilitation Device with Vacuum-Actuated Artificial Muscles
Chen, X., Zhu, K., Feng-chun, H., Gao, W., & Yao, J. (2025) · Actuators · doi:10.3390/act14070304 · Cited by 2
He, Z., Chen, P., Wang, X., Chen, Y., & Sun, T. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500420 · Cited by 2
Wang, Y., Cui, W., Huang, H., Yang, Y., He, X., & Liu, M. (2026) · Rare Metals · doi:10.1002/rar2.70320 · Cited by 2
Design of a portable ankle robot with reductive-burden layout and self-adjustable posture
Zhou, Y. (2023) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062221145495 · Cited by 2
Design and Evaluation of Lightweight Adaptive Flexible Ankle Rehabilitation Robot
Yin, S., Shi, B., Sun, Y., Yaping, H., & Wang, J. (2022) · Journal of Mechanical Engineering · doi:10.3901/jme.2022.09.010 · Cited by 2
Cho, J., Park, T., Kim, S., & Park, Y. (2024) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft60065.2024.10521984 · Cited by 2
Self-citationFlexible Wearable Joint Motion Sensor Based On Multi-Wire Displacement
Baek, Y., & Park, Y. (2024) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft60065.2024.10521975 · Cited by 2
Self-citationComparative analysis of fuzzy logic and ANFIS controllers using a novel robotic ankle-foot orthosis
Govindaraj, G., & Doss, A. S. A. (2025) · Technology and Disability · doi:10.1177/10554181251349326 · Cited by 2
Pasbanian, E., Khashabi, H., Hadjibabaie, F., & Zareinejad, M. (2023) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom60803.2023.10412532 · Cited by 2
Assist-As-Needed Control of Soft Ankle Orthosis for Walking in Patients with Foot Drop
Sheikhi, P., Zareinejad, M., & Talebi, H. A. (2024) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom64545.2024.10903538 · Cited by 1
Ye, F., Rong, W., Li, W., Wong, K., Pang, M., Wai, H., Li, L., Hong, Z., Guo, S., Ma, Z., et al. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202500052 · Cited by 1
Zhao, L., Zhu, C., Xie, Y., Wang, L., Luo, X., Lu, L., Ji, Y., Zeng, X., Wu, S., Huang, P., et al. (2026) · Digital Health · doi:10.1177/20552076261432283 · Cited by 1
Sabr, A. N., Duroobi, A. A. A., & Al-Juboori, L. A. (2025) · Advances in Science and Engineering Technology International Conferences (ASET) · doi:10.1109/aset66891.2025.11427968 · Cited by 1
Ergonomics in assistive technology design: scoping review
Umbelino, L. L., Ferreira, D. M. T. P., & Alonso, C. M. D. C. (2026) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2026.2671838 · Cited by 1
Smart Gait Detection System With IoT and Machine Learning
Shivalila, A. H., Akshay, G., Andrew, G., Pasha, A., & Prakash, A. (2021) · International Conference on Design Innovations for 3Cs Compute Communicate Control (ICDI3C) · doi:10.1109/icdi3c53598.2021.00057 · Cited by 1
de Miguel-Fernández, J., Pescatore, C., Mesa-Garrido, A., Rikhof, C. J. H., Prinsen, E. C., Font-Llagunes, J. M., & Lobo-Prat, J. (2022) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob52689.2022.9925441 · Cited by 1
A Hybrid Anchoring Technology Composed of Reinforced Flexible Shells for a Knee Unloading Exosuit
Yun, S.-S., Bundschu, C. W., & Cho, K. (2023) · Soft Robotics · doi:10.1089/soro.2021.0223 · Cited by 1
Assistive Wearable Lower Limb Robotics: A Review
Faqiri, A. F., Tasal, N., Mutahar, M., & Bakhtyar, A. (2023) · International Journal of Latest Engineering and Management Research (IJLEMR) · doi:10.56581/ijlemr.8.7.01-10 · Cited by 1
de Miguel-Fernández, J., Pescatore, C., Mesa-Garrido, A., Rikhof, C. J. H., Prinsen, E. C., Font-Llagunes, J. M., & Lobo-Prat, J. (2023) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros55552.2023.10341864 · Cited by 1
Design and Simulation of an Active Ankle-Foot Orthosis with Parameter Optimization
Lara-Velazquez, C. A., Ramirez‐Paredes, J., Martínez-Ramírez, I., Núñez, D. A., González-Sandoval, B. V., Torres-Del-Carmen, F., Correa-Tome, F. E., Pérez-Ramírez, L. E., & Velazquez-Bustamante, A. E. (2022) · International Conference on Mechatronics, Electronics and Automotive Engineering (ICMEAE) · doi:10.1109/icmeae58636.2022.00009 · Cited by 1
Xu, B., Sun, J., Wang, Y., Fu, Q., & Lu, Y. (2023) · International Conference on Advanced Cloud and Big Data · doi:10.1109/cbd63341.2023.00018 · Cited by 1
Topology Optimization of Exo‐Glove Poly II for Enhancing Functionality and Wearability
Choi, S. M., Kim, K. B., Kwon, D., Kang, B. B., & Cho, K. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500411 · Cited by 1
Rodríguez García, N. (2022) · Repositorio Institucional E-DocUR (Universidad Del Rosario) · doi:10.48713/10336_21017 · Cited by 1
Application of soft robotic sensors to predict foot and ankle kinematic measurements
Saucier, D. N. (2020) · Cited by 1
The battle for Port-en-Bessin 6-8 June 1944: a medical officer with a Royal Marine Commando.
Jo, F. (1994) · PubMed · Cited by 1
2019 Index IEEE Robotics and Automation Letters Vol. 4
(2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2955867 · Cited by 1
McFadden, M. (2024) · Iowa Research Online (The University of Iowa) · doi:10.25820/etd.007439 · Cited by 1
(2019) · Arizona State University Library Digital Repository (Arizona State University) · Cited by 1
Impact of Foot Splint and Exercises on Foot Drop Incidence Among Ischemic Stroke Patients
Abdelfattah, G., Rageh, T. A., Azer, S., & Khalil, S. S. (2022) · Assiut Scientific Nursing Journal · doi:10.21608/asnj.2022.127347.1342
Research Progress of Ankle Rehabilitation Robot
周, 熙. (2022) · Artificial Intelligence and Robotics Research · doi:10.12677/airr.2022.112022
Seo, W., Lee, H., & Choi, J. (2022) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros47612.2022.9981747
Jayakumar, A., Jorge, D., Bermejo, G., Agujetas, R., Romero Sánchez, F., & Sánchez, F. J. A. (2022) · Congreso Iberoamericano de Ingeniería Mecánica (CIBIM) · doi:10.5944/bicim2022.102
Ankle active rehabilitation based on Intent recognitionPreprint
Lu, Z., Tian, C., Dong, H., Yao, L., & Huang, H. (2023) · Research Square · doi:10.21203/rs.3.rs-2850246/v1
Jayakumar, A., Jorge, D., Bermejo-García, J., Agujetas, R., Romero, F., & Sánchez, F. J. A. (2023) · Springer eBooks · doi:10.1007/978-3-031-38563-6_18
Huang, R., Han, S., Jin, L., Zhou, J., Chen, X., Ruan, S., & Yu, H. (2023) · Lecture notes in computer science · doi:10.1007/978-981-99-6489-5_48
Improvement of Ablution Skills Through the Practice Methode (Drill)
Nasution, A. B. M. D., Tabroni, I., Xavier, M., & Elliot, M. (2023) · Journal Emerging Technologies in Education · doi:10.55849/jete.v1i4.467
Low-cost IMU-based motion capture system and pneumatic exoskeleton design for assistive applications
Chen, Y. (2024) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/179556
A Data-Driven Personalized Gait Generation Method for Ankle Dorsiflexion Assistance on Soft Exosuit
Fang, X., Xu, F., & Li, K. (2024) · China Automation Congress (CAC) · doi:10.1109/cac63892.2024.10865477
(2025) · International Journal of Mechatronics and Applied Mechanics · doi:10.17683/ijomam/issue19.14
Govindaraj, G., & Doss, A. S. A. (2025) · Studies in systems, decision and control · doi:10.1007/978-3-031-86977-8_15
Beghetti, C., Atzeni, E., Salmi, A., & Iuliano, L. (2026) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-026-02398-6
Personalized Robotic Achilles Tendon Utilizing a Semi-Passive Spring with Switching Stiffness *
Seong, M., Heo, H., Lee, H., & Choi, J. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11245843
Joo, E., Kim, C., Im, S., Koo, S. H., & Koh, J. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11246078
Chuang, Y.-C., Tsai, Y.-L., Lin, T. T.-L., Ou-Yang, L.-J., Lee, Y., Cheng, Y.-Y., Liu, C.-C., & Hsu, C.-S. (2024) · Figshare · doi:10.6084/m9.figshare.26615221
Design and control of artificial muscles for robotic applications
Weerakkody, T. H. (2024) · Iowa Research Online (The University of Iowa) · doi:10.25820/etd.007599
Chuang, Y.-C., Tsai, Y.-L., Lin, T. T.-L., Ou-Yang, L.-J., Lee, Y., Cheng, Y.-Y., Liu, C.-C., & Hsu, C.-S. (2024) · Figshare · doi:10.6084/m9.figshare.26615218
Chuang, Y.-C., Tsai, Y.-L., Lin, T. T.-L., Ou-Yang, L.-J., Lee, Y., Cheng, Y.-Y., Liu, C.-C., & Hsu, C.-S. (2024) · Figshare · doi:10.6084/m9.figshare.26615224
Liu, W., Ji, Y., Zhou, M., Song, Y., Zheng, Q. S., Fan, Y., & Yang, X. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.12.503
Design of Orthosis for Ankle Inversion Injuries
Talari, J. K., Malini, M., & Vidyasagar, K. E. C. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-14908-4_17
Fully Screen-Printed Pressure Sensing Insole—From Proof of Concept to Scalable Manufacturing
Walter, P. A., Pepłowski, A., Budny, F., Lepak-Kuc, S., Szałapak, J., Raczyński, T., Korona, M., Zulfiqar, Z., Kotela, A., & Jakubowska, M. (2026) · Sensors · doi:10.3390/s26051456
Aggerwal, S., Lalani, Z., & O’Neil, J. (2026) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/81782
López, G. A. G. (2024) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Yang, M., & Park, Y. (2026) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft67810.2026.11522943
Self-citationA novel Schatz-derived 7R reconfigurable mechanism with double-rocker motion branch
Tang, J., Wang, L., Liu, R., Xing, Y., & Zhang, D. (2026) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2026.106547
Xu, Y., Shi-sheng, Z., Zhang, J., Leng, Y., Zhu, C., & Zhang, Y. (2026) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2026.3712801
Yañes-Martinez, N., Avilés, L. A. Z., Cruz-Martínez, G. M., & Vilchis-González, A. H. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-33769-7.00001-6
Metadata
- Authors
- Kwon, J., Park, J.-H., Ku, S., Jeong, Y., Paik, N.-J., & Park, Y.-L.
- Affiliations
- Seoul National University (KR)
- Seoul National University Bundang Hospital (KR)
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2019-07
- Volume
- 4
- Issue
- 3
- Pages
- 2547-2552
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2925674589
- Semantic Scholar
- 155896e114eff8fc7820995f1e4110b94e0278ee
- Cited by
- 158
- References
- 26
- Citations by year
- 2026: 10 · 2025: 19 · 2024: 20 · 2023: 34 · 2022: 30 · 2021: 22 · 2020: 17 · 2019: 5
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Robotics and Automation Letters (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- National Research Foundation of Korea (NRF-2016R1A5A1938472)
- Seoul National University Bundang Hospital Research Fund (14-2017-025)
- Interdisciplinary Research Initiatives Program (800-20170165)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- ankle-foot orthosis, stroke rehabilitation, gait assistance, tendon-driven actuators, foot pressure sensing, gait phase detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.