Towards Control of Magnetic Fluids in Patients: Directing Therapeutic Nanoparticles to Disease Locations
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This article describes a range of results, from passive magnet design to optimal feedback control of a distributed ferrofluid. Representing magnetic forces as the gradient of a magnetic energy allowed design and demonstration, in animal experiments, of a simple open-loop two-magnet system to inject nanoparticles into the inner ear. Then a petri-dish test bed was used to develop and test optimal closed-loop manipulation of a single ferrofluid droplet.The demonstrated algorithms exploited the quadratic dependence of the magnetic forces on control inputs while accounting for magnet time delays and spatial discontinuities in the optimal control. All dimensional parameters were reduced to three essential nondimensional numbers, and ferrofluid behavior was mapped across the entire feasible drug delivery parameter space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Normalization of Tumor Vasculature: An Emerging Concept in Antiangiogenic Therapy
Jain, R. K. (2005) · Science · doi:10.1126/science.1104819 · Cited by 5,527 · cited 2×
“Chemotherapy injected into the blood must diffuse from blood vessels into tumors; since metastatic cells are further away from blood vessels, they are likely subjected to lower concentrations of chemotherapy, as compared to healthy cells that would receive higher doses [231], [268].”
BackgroundRecent advances with liposomes as pharmaceutical carriers
Torchilin, V. P. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1632 · Cited by 5,282
Dougherty, T. J., Gomer, C. J., Henderson, B. W., Jori, G., Kessel, D., Korbelik, M., Moan, J., & Peng, Q. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.12.889 · Cited by 4,716
Drug Resistance and the Solid Tumor Microenvironment
Tredan, O., Galmarini, C. M., Patel, K., & Tannock, I. F. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm135 · Cited by 2,116 · cited 1×
“Magnetic forces scale with particle volume (4) but tissue resistance forces do not necessarily follow a simple scaling law: they can be modest for small particle sizes and then grow rapidly as particles exceed a certain tissue-dependent size [110], [111], [221].”
BackgroundNoninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381 · cited 2×
“total) have been commercialized and approved for human use, and not yet as therapeutic carriers but only as imaging agents [82]–[85].”
BackgroundMultifunctional polymeric micelles as cancer-targeted, MRI-ultrasensitive drug delivery systems
Nasongkla, N., Bey, E., Ren, J., Ai, H., Khemtong, C., Guthi, J. S., Chin, S.-F., Sherry, A. D., Boothman, D. A., & Gao, J. (2006) · Nano Letters · doi:10.1021/nl061412u · Cited by 1,238
Cellular pharmacology of gemcitabine
Mini, E., Nobili, S., Caciagli, B., Landini, I., & Mazzei, T. (2006) · Annals of Oncology · doi:10.1093/annonc/mdj941 · Cited by 842
Cole, A. J., David, A. E., Wang, J., Galbán, C. J., Hill, H. L., & Yang, V. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.040 · Cited by 308 · cited 3×
“Even for carefully engineered “stealth-coated” nanoparticles, about half of the particle dosage (about 50% of the Chemicell particles used in [11]) is caught within minutes and sequestered to the liver, spleen, and kidneys [71].”
BackgroundEngineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262 · cited 19×
“Conventional MRI machines have also been used as the actuation system to manipulate microscale particles [137], [148]–[152] as well as magnetotactic bacteria [99], [153] or magnetized cells [81], [154]–[157], in pigs and mice [149], [154].”
BackgroundInfluentialPolyak, B., Fishbein, I., Chorny, M., Alferiev, I., Williams, D., Yellen, B., Friedman, G., & Levy, R. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708338105 · Cited by 257 · cited 1×
“Such a treatment has been envisioned to bring magnetized endothelial cells to blood vessel walls and could also be appropriate for treating tumors that cannot be surgically removed but when magnetizable implants can be inserted into or near the tumor [178]–[181], [187], [190].”
BackgroundWilson, M. W., Kerlan, R. K., Fidelman, N. A., Venook, A. P., LaBerge, J. M., Koda, J., & Gordon, R. L. (2004) · Radiology · doi:10.1148/radiol.2301021493 · Cited by 190 · cited 5×
“The particles may be injected into a blood vessel immediately upstream of the known disease location, after which magnets are used to try to capture and confine the therapy as it flows by on its first pass [73], [164], [168].”
BackgroundInfluential
Cited by
Iron Oxide Based Nanoparticles for Multimodal Imaging and Magnetoresponsive Therapy
Lee, N., Yoo, D., Ling, D., Cho, M. H., Hyeon, T., & Cheon, J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00112 · Cited by 1,005
Stamps, R. L., Breitkreutz, S., Åkerman, J., Chumak, A. V., Otani, Y., Bauer, G. E. W., Thiele, J.-U., Bowen, M., Majetich, S. A., Kläui, M., et al. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/33/333001 · Cited by 361
A review of magnet systems for targeted drug delivery
Liu, Y.-L., Chen, D., Shang, P., & Yin, D.-C. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.031 · Cited by 298
Dynamic Inversion Enables External Magnets To Concentrate Ferromagnetic Rods to a Central Target
Nacev, A., Weinberg, I. N., Stepanov, P. Y., Kupfer, S., Mair, L. O., Urdaneta, M. G., Shimoji, M., Fricke, S. T., & Shapiro, B. (2015) · Nano Letters · doi:10.1021/nl503654t · Cited by 74
Self-citationSteering Magnetic Nanoparticles by Utilizing an Adjustable Linear Halbach Array
Thalmayer, A. S., Zeising, S., Fischer, G., & Kirchner, J. (2021) · 2021 Kleinheubach Conference · doi:10.23919/ieeeconf54431.2021.9598436 · Cited by 13
Metadata
- Authors
- Nacev, A., Komaee, A., Sarwar, A., Probst, R., Kim, S. H., Emmert-Buck, M., & Shapiro, B.
- Venue
- IEEE Control Systems
- Published
- 2012-06
- Volume
- 32
- Issue
- 3
- Pages
- 32-74
- ISSN
- 1066-033X (ISSN-L)
- OpenAlex
- W2054579949
- Cited by
- 104
- References
- 12
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.