An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes an ultra-compliant parylene-platinum neural probe embedded in a biodissolvable delivery vehicle. High probe compliance is achieved using thin wires (width of 10.0 μm and thickness of 2.7 μm) and by meandering the probe. The insertion of the ultra-compliant probe is achieved by encasing it in a dissolvable delivery vehicle made from molded carboxy-methylcellulose. In vivo implantations of delivery vehicles with 1.5 mm long shanks, widths of 100 μm and 300 μm and a targeted thickness of 135 μm have been done through the dura in the cortex of Sprague-Dawley rats at a speed of 80 mm-s-1. The delivery vehicle becomes a gel over a period of less than three minutes, after which the handling portions of the delivery vehicle are removed leaving the shanks embedded in the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“The literature suggests neural tissue recovers from acute injury but has a chronic reactive response to the implanted electrode [1,2].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 1×
“The literature suggests neural tissue recovers from acute injury but has a chronic reactive response to the implanted electrode [1,2].”
BackgroundNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · cited 3×
“State-of-the-Art Intracortical probes are traditionally made from materials like Si, W and Pt that have elastic moduli of 100’s of GPa, compared to brain tissue that has an elastic modulus on the order of 10’s of kPa [3,4].”
BackgroundMethod
Cited by
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Self-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Self-citationProgress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Other degradable shuttles that have also been investigated include poly(lactic acid), glucose and gelatin [212, 222, 224–228].”
BackgroundKozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
Self-citationUltrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Self-citationKozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
“27 adult male SpragueeDawley rats (Charles River Laboratories) weighing 300e350 g were prepared for cortical implants using previously established methods [46] approved by the University of Pittsburgh, Division of Laboratory Animal Resources and Institutional Animal Care and Use Committee in accordancewith”
MethodSelf-citationFlexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“However, molds may be difficult to fill by hand and may require centrifugation to assist in the elimination of bubbles from the coating material, and stress-induced curling and shrinkage of the coated probe post-removal from the mold may interfere with the ability of the probe to penetrate properly during implantation…”
BackgroundMethodInfluentialTakmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
“Furthermore, ultrasmall electrodes may be needed to extend early benefits to long-term performance [23, 24].”
BackgroundSelf-citationAmorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes
Wu, F., Tien, L. W., Chen, F., Berke, J. D., Kaplan, D. L., & Yoon, E. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2375326 · Cited by 80
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
A multi-shank silk-backed parylene neural probe for reliable chronic recording
Wu, F., Tien, L., Chen, F., Kaplan, D., Berke, J., & Yoon, E. (2013) · 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII) · doi:10.1109/transducers.2013.6626910 · Cited by 24
Metadata
- Authors
- Gilgunn, P. J., Khilwani, R., Kozai, T. D. Y., Weber, D. J., Cui, X. T., Erdos, G., Ozdoganlar, O. B., & Fedder, G. K.
- Venue
- 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS)
- Publisher
- IEEE
- Published
- 2012-01
- Pages
- 56-59
- ISSN
- 1084-6999 (ISSN-L)
- OpenAlex
- W2053887367
- Cited by
- 65
- References
- 3
- FWCI
- 33.09
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.