Miniature ultrasonically powered wireless nerve cuff stimulator
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present a wireless neural stimulator composed of only three discrete components. The capsule was 8 mm long and was designed to be clasped directly upon a peripheral nerve. Power was supplied by low-intensity 1 MHz ultrasound transmitted into the body. The prototype was capable of generating currents in excess of 1 mA. For in vivo testing the device was implanted in a rat hind limb on the sciatic nerve, and when insonated with pulse intensities of 10-150 mW/cm2the stimulator excited motor axons inducing predictable contractions of the lower leg muscles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · cited 1×
“Wires used in implantable stimulators have a number of drawbacks including a higher degree of difficulty and invasiveness during surgery, a risk of infection, a substrate for growth of scar tissue, potential for lead breakage due to flexure or impact, and irritation or damage to tissues due to inherent differences in…”
BackgroundBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243 · cited 1×
“The capsule is a ceramic cylinder 2 mm diameter by 16 mm long [3].”
Background
Cited by
Piezoelectric materials for tissue regeneration: A review
Rajabi, A. H., Jaffe, M., & Arinzeh, T. L. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.010 · Cited by 635
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
“In contrast to EM, ultrasound offers an attractive alternative for wirelessly powering and communicating with sub-mm implantable devices (Charthad et al., 2015; Larson and Towe, 2011; Meng and Sahin 2013; Ozeri and Shmilovitz, 2010; Seo et al., 2014).”
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
“Ultrasonic power transfer is an emerging alternative approach for implants [15], [22], [23], [27]–[29], and has several key”
BackgroundInfluentialShi, Q., Wang, T., & Lee, C. (2016) · Scientific Reports · doi:10.1038/srep24946 · Cited by 210
Acoustic Energy Transfer: A Review
Roes, M. G. L., Duarte, J. L., Hendrix, M. A. M., & Lomonova, E. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2202362 · Cited by 209
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Holzapfel, L., & Giagka, V. (2022) · doi:10.1101/2022.08.23.503752 · Cited by 12
Metadata
- Authors
- Larson, P. J., & Towe, B. C.
- Venue
- 2011 5th International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2011-04
- Pages
- 265-268
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2134454410
- Cited by
- 75
- References
- 2
- FWCI
- 15.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.