The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Computerized tomography with X-ray, emission, and ultrasound sources
Abstract
This paper reviews the major developments that have taken place during the last three years in imaging with computed tomography (CT) using X-ray, emission, and ultrasound sources. Space limitations have resulted in some selection of topics by the author. There are four major sections dealing with algorithms, X-ray CT, emission CT, and ultrosound CT. Since most of the currently used algorithms are of filtered-backprojection type, we have concentrated on these in the section on algorithms (with emphasis on their implementation aspects). In X-ray CT an important question raised during the last few years has concerned the parameter measured by a CT scanner, given the fact that the X-rays used in CT scanners are polychromatic and the fact that tissue attenuation coefficients are energy dependent. Answers to this question are reviewed in the section on X-ray CT where we have also discussed the artifacts caused by the polychromaticity of the X-ray photons. Methods for the removal of these artifacts have also been reviewed. In emission CT the biggest development of the last three years is the great interest in positron tomography, although space constraints have dictated an essentially introductory treatment and not all aspects of the single photon and positron tomography have been surveyed. Finally, we have reviewed recent developments in ultrasound CT. We have pointed out that because of the sensitivity of this technique to refraction, it is currently limited to soft tissue structures, with ultrasonic detection of tumors in the female breast a significant application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
Reconstruction of Three Dimensional Structures from Electron Micrographs
DE ROSIER, D. J., & KLUG, A. (1968) · Nature · doi:10.1038/217130a0 · Cited by 1,345
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297
Ramachandran, G. N., & Lakshminarayanan, A. V. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.9.2236 · Cited by 984
Gold, B., & Rader, C. M. (1969) · CERN Document Server (European Organization for Nuclear Research) · Cited by 940
Strip Integration in Radio Astronomy
Bracewell, R. (1956) · Australian Journal of Physics · doi:10.1071/ph560198 · Cited by 682
Beam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 606
Hubbell, J. H. (1969) · doi:10.6028/nbs.nsrds.29 · Cited by 598
Image Separation Radioisotope Scanning
Kuhl, D. E., & Edwards, R. Q. (1963) · Radiology · doi:10.1148/80.4.653 · Cited by 423
Photon attenuation in computed tomography
McCullough, E. C. (1975) · Medical Physics · doi:10.1118/1.594199 · Cited by 287
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281
ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals
Phelps, M. E., Hoffman, E. J., Huang, S. C., & Kuhl, D. E. (1977) · doi:10.2172/5423721 · Cited by 241
The Use of Positron-emitting Radioisotopes for the Localization of Brain Tumors
Wrenn, F. R., Good, M. L., & Handler, P. (1951) · Science · doi:10.1126/science.113.2940.525 · Cited by 235
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Design and performance characteristics of a whole-body positron transaxial tomograph.
Ej, H., Phelps, M. E., Mullani, N. A., Higgins, C. S., & Mm, T.-P. (1976) · PubMed · Cited by 153
Ultrasonic Reflectivity Tomography: Reconstruction with Circular Transducer Arrays
Norton, S. J., & Linzer, M. (1979) · Ultrasonic Imaging · doi:10.1177/016173467900100205 · Cited by 152
Phelps, M. E., Hoffman, E. J., & Ter‐Pogossian, M. M. (1975) · Radiology · doi:10.1148/117.3.573 · Cited by 145
Statistical limitations in transaxial tomography
Barrett, H. H., Gordon, S. K., & Hershel, R. S. (1976) · Computers in Biology and Medicine · doi:10.1016/0010-4825(76)90068-8 · Cited by 110
Design Considerations for a Positron Emission Transverse Tomograph (PETT V) for Imaging of the Brain
Ter‐Pogossian, M. M., Mullani, N. A., Hood, J. T., Higgins, C. S., & Ficke, D. C. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197811000-00002 · Cited by 103
Polychromatic Streak Artifacts in Computed Tomography Images
Duerinckx, A. J., & Macovski, A. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197809000-00020 · Cited by 72
Cited by
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
A Filtered Backpropagation Algorithm for Diffraction Tomography
Devaney, A. J. (1982) · Ultrasonic Imaging · doi:10.1177/016173468200400404 · Cited by 727
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
Pan, S., & Kak, A. (1983) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1983.1164196 · Cited by 317
Self-citationWithayachumnankul, W., Png, G. M., Yin, X., Atakaramians, S., Jones, I., Lin, H., Ung, B. S. Y., Balakrishnan, J., Ng, B. W.-H., Ferguson, B., et al. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.900325 · Cited by 179
Metadata
- Authors
- Kak, A. C.
- Venue
- Proceedings of the IEEE
- Published
- 1979
- Volume
- 67
- Issue
- 9
- Pages
- 1245-1272
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2084653147
- Cited by
- 264
- References
- 23
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.