The DOI matches its Crossref record; 305 of the 305 references it cites were found in a registry or an index.
Diabetes: Models, Signals, and Control
Open accessAbstract
The control of diabetes is an interdisciplinary endeavor, which includes a significant biomedical engineering component, with traditions of success beginning in the early 1960s. It began with modeling of the insulin-glucose system, and progressed to large-scale in silico experiments, and automated closed-loop control (artificial pancreas). Here, we follow these engineering efforts through the last, almost 50 years. We begin with the now classic minimal modeling approach and discuss a number of subsequent models, which have recently resulted in the first in silico simulation model accepted as substitute to animal trials in the quest for optimal diabetes control. We then review metabolic monitoring, with a particular emphasis on the new continuous glucose sensors, on the analyses of their time-series signals, and on the opportunities that they present for automation of diabetes control. Finally, we review control strategies that have been successfully employed in vivo or in silico, presenting a promise for the development of a future artificial pancreas and, in particular, discuss a modular architecture for building closed-loop control systems, including insulin delivery and patient safety supervision layers. We conclude with a brief discussion of the unique interactions between human physiology, behavioral events, engineering modeling and control relevant to diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“The development of artificial pancreas control algorithms in the past few years has been accelerated by computer simulation; for example, in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425 · cited 1×
“In numerous studies reviewed in [27], insulin sensitivity estimated with the minimal model has been shown to strongly correlate to that measured with the euglycemic-hyperinsulinemic clamp [36], calculated as the steady-state glucose infusion rate divided by basal glucose times the above basal increase in insulin conce…”
Sokoloff, L., Reivich, M., Kennedy, C., Rosiers, M. H. D., Patlak, C. S., Pettigrew, K. D., Sakurada, O., & Shinohara, M. (1977) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1977.tb10649.x · Cited by 6,000
Global and societal implications of the diabetes epidemic
Zimmet, P., Alberti, K. G. M. M., & Shaw, J. (2001) · Nature · doi:10.1038/414782a · Cited by 5,883 · cited 2×
“Rapid urbanization and societal affluence of global migrating populations has been suggested as major risk factors for the observed exploding prevalence of prediabetes and type 2 diabetes with consequent rising trends in cardiovascular risks [8].”
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 1×
“3) Hormone Pulsatility and Approximate Entropy: Approximate Entropy (ApEn) is a method developed in the early 1990s [171] to quantify the “regularity” of a time series.”
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 33×
“In fact, during IVGTT first phase component only contributed during the first 4–6 minutes and the proportional component for the rest of test.”
InfluentialSelf-citationBergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640 · cited 3×
“One possibility is to resort to a normalization of beta-cell function based on the disposition index paradigm, first introduced in 1981 [35], and recently revisited in [28], where beta-cell function is multiplied by insulin sensitivity.”
Self-citationContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
(1999) · The Lancet · doi:10.1016/s0140-6736(98)12131-1 · Cited by 1,313
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · cited 2×
“The model [136] has been built for being the model in-”
Borch‐Johnsen, K., Neil, A., Balkau, B., Larsen, S. H., Nissinen, A. E. T., Pekkanen, J., Keinanen-Kiukaanniemi, S. M., Hiltunen, L. A., Kivelä, S., Tuomilehto, J. O., et al. (1999) · The Lancet · Cited by 1,272
Research works printed but not linked: 15
- 10.1210/jc.80.1.28 · DOI
- 10.1210/jc.81.10.3746 · DOI
- patek, 2007, Adaptive meal detection algorithm enabling closed-loop control in type 1 diabetes, Proc Diabetes Technology Meeting
- 10.1210/jc.82.12.4088 · DOI
- 10.1210/jc.84.6.1938 · DOI
- bassingthwaighte, 1984, Handbook of Physiology The Cardiovascular System Microcirculation
- utriainen, 1998, Lumped constant for [14C]deoxy-D-glucose in human skeletal muscle, Diabetologia, 41, 187a
- palerm, 2005, Hypoglycemia prediction and detection using optimal estimation, Diabetes Technol Therapeutics, 7, 3, 10.1089/dia.2005.7.3 · DOI
- 10.1177/193229680700100505 · DOI
- dalla man, 2009, A pre & type 2 diabetes simulator for in silico trials, Proc Ninth Diabetes Technology Meeting
- pickup, 1991, Textbook of Diabetes, 2
- denti, 2009, A nonlinear mixed-effects approach to the estimation of the glucose disposition index, Proc PAGE 2009 Meeting
- toffolo, 2001, Quantitative indexes of beta-cell function during graded up&down glucose infusion from C-peptide minimal models, Amer J Physiol Endocrinol Metab, 280, 2e, 10.1152/ajpendo.2001.280.1.E2 · DOI · Paper page
- patek, 2009, Control of hypoglycemia via estimation of active insulin, glucose forecasts, and risk-based insulin reduction, Proc 2nd Advanced Technol Treatment for Diabetes
- 2009, Nonlinear Model Predictive Control Towards New Challenging Applications, 384
Cited by
Sorted by citations
Items 501–509 of 509
Personalized Digital Twins for Improved Glycemic Control in Type 1 Diabetes
Chuprakov, D. A., & Витольдович, П. К. (2026) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit70063.2026.11580426
Open Newton-Cotes Method for Blood Glucose Dynamics in Diabetic Patients
Marjulisa, R., & Lily, E. (2026) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3276/1/012011
“Blood glucose dynamics are influenced by multiple interacting factors, including food intake, physical activity, insulin administration, and insulin sensitivity [3,4].”
D-Care 2.0: A Multi-tone Multi-LLM Chatbot Assistant for New Diabetes Patients
Nawabi, A. K., Bianchi, E., Toffanin, C., & Dondi, P. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-34459-5_20
Shaker, R. A., Sardahi, Y., & Alshorman, A. M. (2026) · Automation · doi:10.3390/automation7040128
“Recent studies [36,37] demonstrate that the model accurately predicts glucose excursions during variations in exogenous insulin delivery, such as bolus and basal adjustments.”
Zhou, Y., Liu, X., Zhao, S., & Zhao, Y. (2026) · Bulletin of Mathematical Biology · doi:10.1007/s11538-026-01678-4
Roquemen-Echeverri, V., Escorihuela‐Altaba, C., Kushner, T., Jacobs, P. G., Garcia‐Tirado, J., & MOSQUERA-LOPEZ, C. M. (2026) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2026.08.001
Kiaei, D., Tourajizadeh, H., & Fard, B. M. (2026) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119261490966
Andrade, L. J. D. O., de Oliveira, G. C. M., Salles, O. J. D. M., Al, B., Ferreira, V. S. C., & de Oliveira, L. M. (2026) · Research Square · doi:10.21203/rs.3.rs-11253592/v1
Abu-Rmileh, A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Metadata
- Authors
- Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P.
- Affiliations
- University of Padua (IT)
- University of Pavia (IT)
- University of Virginia (US)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2009
- Volume
- 2
- Pages
- 54-96
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- PMC
- PMC2951686
- OpenAlex
- W2171613573
- Cited by
- 511
- References
- 304
- Citations by year
- 2026: 13 · 2025: 27 · 2024: 11 · 2023: 17 · 2022: 25 · 2021: 27 · 2020: 32 · 2019: 27 · 2018: 39 · 2017: 42 · 2016: 29 · 2015: 40 · 2014: 44 · 2013: 39 · 2012: 43
- FWCI
- 24.04
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01-DK-051562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- diabetes management, computer simulation, artificial pancreas, feedback control, continuous glucose monitoring, modular control architecture
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review