The DOI matches its Crossref record; 305 of the 305 references it cites were found in a registry or an index.
Diabetes: Models, Signals, and Control
Open accessAbstract
The control of diabetes is an interdisciplinary endeavor, which includes a significant biomedical engineering component, with traditions of success beginning in the early 1960s. It began with modeling of the insulin-glucose system, and progressed to large-scale in silico experiments, and automated closed-loop control (artificial pancreas). Here, we follow these engineering efforts through the last, almost 50 years. We begin with the now classic minimal modeling approach and discuss a number of subsequent models, which have recently resulted in the first in silico simulation model accepted as substitute to animal trials in the quest for optimal diabetes control. We then review metabolic monitoring, with a particular emphasis on the new continuous glucose sensors, on the analyses of their time-series signals, and on the opportunities that they present for automation of diabetes control. Finally, we review control strategies that have been successfully employed in vivo or in silico, presenting a promise for the development of a future artificial pancreas and, in particular, discuss a modular architecture for building closed-loop control systems, including insulin delivery and patient safety supervision layers. We conclude with a brief discussion of the unique interactions between human physiology, behavioral events, engineering modeling and control relevant to diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“The development of artificial pancreas control algorithms in the past few years has been accelerated by computer simulation; for example, in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425 · cited 1×
“In numerous studies reviewed in [27], insulin sensitivity estimated with the minimal model has been shown to strongly correlate to that measured with the euglycemic-hyperinsulinemic clamp [36], calculated as the steady-state glucose infusion rate divided by basal glucose times the above basal increase in insulin conce…”
Sokoloff, L., Reivich, M., Kennedy, C., Rosiers, M. H. D., Patlak, C. S., Pettigrew, K. D., Sakurada, O., & Shinohara, M. (1977) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1977.tb10649.x · Cited by 6,000
Global and societal implications of the diabetes epidemic
Zimmet, P., Alberti, K. G. M. M., & Shaw, J. (2001) · Nature · doi:10.1038/414782a · Cited by 5,883 · cited 2×
“Rapid urbanization and societal affluence of global migrating populations has been suggested as major risk factors for the observed exploding prevalence of prediabetes and type 2 diabetes with consequent rising trends in cardiovascular risks [8].”
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 1×
“3) Hormone Pulsatility and Approximate Entropy: Approximate Entropy (ApEn) is a method developed in the early 1990s [171] to quantify the “regularity” of a time series.”
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 33×
“In fact, during IVGTT first phase component only contributed during the first 4–6 minutes and the proportional component for the rest of test.”
InfluentialSelf-citationBergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640 · cited 3×
“One possibility is to resort to a normalization of beta-cell function based on the disposition index paradigm, first introduced in 1981 [35], and recently revisited in [28], where beta-cell function is multiplied by insulin sensitivity.”
Self-citationContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
(1999) · The Lancet · doi:10.1016/s0140-6736(98)12131-1 · Cited by 1,313
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · cited 2×
“The model [136] has been built for being the model in-”
Borch‐Johnsen, K., Neil, A., Balkau, B., Larsen, S. H., Nissinen, A. E. T., Pekkanen, J., Keinanen-Kiukaanniemi, S. M., Hiltunen, L. A., Kivelä, S., Tuomilehto, J. O., et al. (1999) · The Lancet · Cited by 1,272
Williams Textbook of Endocrinology
Stoffer, S. S. (1999) · JAMA · doi:10.1001/jama.281.9.851 · Cited by 1,245
Nonlinear Models for Repeated Measurement Data
Young, D. A., Davidian, M., & Giltinan, D. M. (1997) · Journal of the American Statistical Association · doi:10.2307/2965730 · Cited by 1,226
Algorithms for the study of episodic hormone secretion
Merriam, G. R., & Wachter, K. W. (1982) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1982.243.4.e310 · Cited by 1,221 · cited 1×
“Peakdetection methods provide information on pulse amplitude and location [161]–[164], while spectral/correlation analysis seeks to identify cycles in time series [165], [166].”
Toward Physiological Understanding of Glucose Tolerance: Minimal-Model Approach
Bergman, R. N. (1989) · Diabetes · doi:10.2337/diab.38.12.1512 · Cited by 1,001
Compartmental analysis in Biology and Medicine
Anderson, D. H. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90168-9 · Cited by 997
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · cited 6×
“In addition to the simulator described above [137], [247], an-”
InfluentialSelf-citationCauter, E. V., Mestrez, F., Sturis, J., & Polonsky, K. S. (1992) · Diabetes · doi:10.2337/diab.41.3.368 · Cited by 887 · cited 3×
“To eliminate the need for a separate experiment to evaluate the impulse response function, a method has been proposed [94] to derive C-peptide kinetic parameters in an individual based on data about his or her age, weight, height and gender.”
Molecular networks as sensors and drivers of common human diseases
Schadt, E. E. (2009) · Nature · doi:10.1038/nature08454 · Cited by 814 · cited 1×
“However, in this review we have to limit our scope; thus, we will not be able to discuss modeling in the areas of patient management [9], [10] and health care intervention strategies [11]–[14], or in the emerging area of systems biology [15], [16].”
The Burden of Mortality Attributable to Diabetes
Roglić, G., Unwin, N. C., Bennett, P. H., Mathers, C. D., Tuomilehto, J. O., Nag, S., Connolly, V. M., & King, H. O. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.9.2130 · Cited by 809
Twenty-four-hour profiles and pulsatile patterns of insulin secretion in normal and obese subjects.
Polonsky, K. S., Given, B. D., & Van Cauter, E. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113339 · Cited by 763 · cited 1×
“Deconvolution methods have been applied to estimate the secretion profile in various physiological states [89], [90] and during both intravenous and oral glucose tolerance tests [91]–[93].”
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 725
Cauter, E. V., Mestrez, F., Sturis, J., et al. (1992) · Diabetes · doi:10.2337/diabetes.41.3.368 · Cited by 643
WEINZIMER, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
DHEA in elderly women and DHEA or testosterone in elderly men.
Nair, K. S., Rizza, R. A., O'Brien, P., Dhatariya, K., Short, K. R., Nehra, A., Vittone, J. L., Klee, G. G., Basu, A., Basu, R., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054629 · Cited by 566
Self-citationDeiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Bonora, E., Moghetti, P., Zancanaro, C., CIGOLINI, M., Querena, M., Cacciatori, V., Corgnati, A., & Muggeo, M. (1989) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-68-2-374 · Cited by 528 · cited 1×
“Impaired insulin transport within the muscle is a well-recognized characteristic of a number of metabolic diseases, including type 2 diabetes, obesity, hypertension, and cardiovascular disease [69].”
Fasting and Postchallenge Glycemia and Cardiovascular Disease Risk
Meigs, J. B., Nathan, D. M., D’Agostino, R. B., & Wilson, P. W. F. (2002) · Diabetes Care · doi:10.2337/diacare.25.10.1845 · Cited by 509 · cited 2×
“Furthermore, both IFG and IGT are linked to increased risk for cardiovascular events [6], [7] in the Caucasian population.”
Banting Lecture 1997. Control of glucose uptake and release by the liver in vivo.
Cherrington, A. D. (1999) · Diabetes · doi:10.2337/diabetes.48.5.1198 · Cited by 500 · cited 18×
“Finally, the model incorporates the accepted notion that a portal insulin signal (here is approximated by glucose derivative) controls the rapid suppression of EGP [60].”
InfluentialFeasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C. H., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473 · cited 1×
“control experiments used a PID controller [259], [260], [290],”
A model of the kinetics of insulin in man
Sherwin, R. S., Kramer, K. J., Tobin, J. D., Insel, P. A., Liljenquist, J. E., Berman, M., & Andres, R. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107697 · Cited by 460 · cited 2×
“This was a model ingredient requested by data and modeling methodology, in agreement with [24].”
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 440 · cited 1×
“This subject has been discussed by numerous research papers since the 1960s, and several surveys are now available [223], [243].”
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S. K., Zisser, H., Schwartz, S. L., Bailey, T. S., Kaplan, R. A., Ellis, S. L., & Jovanovič, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 429
(1985) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 417
A physiological model of glucose-insulin interaction in type 1 diabetes mellitus.
Lehmann, E., & Deutsch, T. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90058-s · Cited by 410
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404 · cited 1×
“of the direction of BG change [196], [207], [208].”
Increased prevalence of insulin resistance and nonalcoholic fatty liver disease in Asian-Indian men
Petersen, K. F., Dufour, S., Feng, J., Befroy, D., Dziura, J., Man, C. D., Cobelli, C., & Shulman, G. I. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608537103 · Cited by 403 · cited 1×
“For instance, the battery of oral glucose, C-peptide, and insulin models have been used in studying: the effect of age and gender on glucose metabolism [59]; the effect of anti-aging drugs [110]; the influence of ethnicity [111]; insulin sensitivity and beta-cell function in nondiabetic [112] and obese [113] adolescen…”
Self-citationPartitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393 · cited 1×
“, -glucose) label, was first interpreted with one [48]–[51] and, subsequently, with a two-compartment minimal model [52], [53], [55], [56] which has been shown to be more accurate.”
A threshold distribution hypothesis for packet storage of insulin and its mathematical modeling
Grodsky, G. M. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107011 · Cited by 391 · cited 9×
“Grodsky [120] proposed that insulin was located in “packets,””
InfluentialRebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 367 · cited 2×
“fall in IG would precede fall in BG [196], [212].”
Prehepatic Insulin Production in Man: Kinetic Analysis Using Peripheral Connecting Peptide Behavior*
EATON, R. P., ALLEN, R. C., SCHADE, D. S., ERICKSON, K. M., & STANDEFER, J. (1980) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-51-3-520 · Cited by 363 · cited 2×
“Since the secretion model is identified on C-peptide measurements taken in plasma, it must be integrated into a model of whole-body C-peptide kinetics, which has two compartments [88].”
Polonsky, K. S., Licinio-Paixao, J., Given, B. D., Pugh, W., Rue, P., Galloway, J., Karrison, T., & Frank, B. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112308 · Cited by 359 · cited 1×
“Deconvolution methods have been applied to estimate the secretion profile in various physiological states [89], [90] and during both intravenous and oral glucose tolerance tests [91]–[93].”
Coefficients of normal blood glucose regulation
Bolie, V. W. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.5.783 · Cited by 349 · cited 2×
“intravenous administration of glucose, was the pioneering study of Bolie in 1961 [29]”
Evaluation of a New Measure of Blood Glucose Variability in Diabetes
Kovatchev, B. P., Otto, E., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W. L. (2006) · Diabetes Care · doi:10.2337/dc06-1085 · Cited by 344
Self-citationSparacino, G., Zanderigo, F., Corazza, S., Maran, A., Facchinetti, A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889774 · Cited by 339
Self-citationPincus, S. M., Mulligan, T., Iranmanesh, A., Gheorghiu, S., Godschalk, M., & Veldhuis, P. P. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.24.14100 · Cited by 337 · cited 1×
“An extension of this theory has also been proposed to analyze the synchrony of two time series belonging to the same physiologic network through the Cross Approximate Entropy index [173].”
Effects of Age and Sex on Postprandial Glucose Metabolism
Basu, R., Dalla Man, C., Campioni, M., Basu, A., Klee, G., Toffolo, G., Cobelli, C., & Rizza, R. A. (2006) · Diabetes · doi:10.2337/db05-1692 · Cited by 334
Self-citationClosed-loop insulin delivery-the path to physiological glucose control.
Steil, G., Panteleon, A., & Rebrin, K. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 325 · cited 1×
“control experiments used a PID controller [259], [260], [290],”
Oral Glucose Tolerance Test Minimal Model Indexes of β-Cell Function and Insulin Sensitivity
Breda, E., Cavaghan, M. K., Toffolo, G., Polonsky, K. S., & Cobelli, C. (2001) · Diabetes · doi:10.2337/diabetes.50.1.150 · Cited by 320
Self-citationCobelli, C., Toffolo, G., Man, C. D., Campioni, M., Denti, P., Caumo, A., Butler, P., & Rizza, R. (2007) · American Journal of Physiology. Endocrinology and Metabolism · doi:10.1152/ajpendo.00421.2006 · Cited by 320 · cited 4×
“It exerts derivative control, since it is proportional to the rate of increase of glucose from basal up to the maximum through a parameter [28], , which defines the first responsivity index”
InfluentialSelf-citationModel Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317 · cited 1×
“bration of a scalar aggressiveness parameter [270].”
Self-citationKovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., Young-Hyman, D. L., Schlundt, D. G., & Clarke, W. L. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1870 · Cited by 309 · cited 1×
“The LBGI, which is based on the left branch of the BG Risk Function r(BG) has been validated as an excellent predictor of future significant hypoglycemia [186], [187].”
Self-citationArtificial Neural Network Algorithm for Online Glucose Prediction from Continuous Glucose Monitoring
Pérez-Gandía, C., Facchinetti, A., Sparacino, G., Cobelli, C., Aguilera, E. J. G., Rigla, M., de Leiva, A., & Hernando, M. E. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0076 · Cited by 307
Self-citationMeal and oral glucose tests for assessment of β-cell function: modeling analysis in normal subjects
Mari, A., Schmitz, O., Gastaldelli, A., Oestergaard, T., Nyholm, B., & Ferrannini, E. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00093.2002 · Cited by 303 · cited 2×
“Various models have been proposed to assess beta-cell function during a meal and OGTT [95], [100]–[102].”
Fast insulin secretion reflects exocytosis of docked granules in mouse pancreatic B-cells
Olofsson, C. S., Göpel, S. O., Barg, S., Galvanovskis, J., Ma, X., Salehi, A., Rorsman, P., & Eliasson, L. (2002) · Pflügers Archiv · doi:10.1007/s00424-002-0781-5 · Cited by 290
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 271 · cited 2×
“As observed by [243], this means that after a meal,”
Eddy, D. M., & Schlessinger, L. (2003) · Diabetes Care · doi:10.2337/diacare.26.11.3093 · Cited by 258
Symmetrization of the Blood Glucose Measurement Scale and Its Applications
Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.11.1655 · Cited by 258 · cited 3×
“A key element to the interpretation of SMBG signals is the use of the BG Risk Space, which was introduced over ten years ago and was based on a transformation of the BG scale that corrects an inherent asymmetry of the hypoglycemic versus hyperglycemic ranges [184].”
Self-citationEffect of insulin on the distribution and disposition of glucose in man.
Ferrannini, E., Smith, J. D., Cobelli, C., Toffolo, G., Pilo, A., & DeFronzo, R. A. (1985) · Journal of Clinical Investigation · doi:10.1172/jci111969 · Cited by 254 · cited 2×
“4 shows the model-derived parametric representations of basal and elevated-insulin state obtained in [21] and [23] by identifying the tracer model of Fig.”
Self-citationGIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253 · cited 2×
“ment model approximating nonmonomeric and monomeric insulin fractions in the subcutaneous space [285], which can serve as a base for the translation of the insulin signal from the pump”
Self-citationPhysiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 252
Computer model for mechanisms underlying ultradian oscillations of insulin and glucose
Sturis, J., Polonsky, K. S., Mosekilde, E., & Van Cauter, E. (1991) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1991.260.5.e801 · Cited by 251 · cited 1×
“[121], which offered an explanation of why wide ultradian oscillations (period of 120 min in humans) occur in insulin and glucose profiles in various physiological conditions, stating that they can originate from the interaction between the glucose and insulin subsystems without the need to invoke the presence of a pa…”
Statistical Tools to Analyze Continuous Glucose Monitor Data
Clarke, W. L., & Kovatchev, B. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0138 · Cited by 248
Self-citationInsulin Control of Glucose Metabolism in Man
Insel, P. A., Liljenquist, J. E., Tobin, J. D., Sherwin, R. S., Watkins, P., Andres, R., & Berman, M. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108006 · Cited by 244 · cited 2×
“Multiple steady-state tracer data allow not only inference of the effect of insulin on glucose masses, fluxes, and rate parameters, but also on the timing and magnitude of insulin control [20].”
Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting Insulin
Wilinska, M. E., Chassin, L. J., Schaller, H. C., Schaupp, L., Pieber, T. R., & Hovorka, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839639 · Cited by 242 · cited 2×
“The model, coupled to a subcutaneous insulin kinetic model [142], consists of 11 dif-”
The oral glucose minimal model: Estimation of insulin sensitivity from a meal test
Della Man, C., Caumo, A., & Cobelli, C. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995680 · Cited by 241 · cited 1×
“The oral glucose minimal model (OMM) builds on the IVGTT minimal model by parametrically describing the rate of appearance of glucose into plasma (Ra) [45].”
Self-citationComparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors
Kovatchev, B. P., Anderson, S. M., Heinemann, L., & Clarke, W. L. (2008) · Diabetes Care · doi:10.2337/dc07-2401 · Cited by 236
Self-citationBock, G., Dalla Man, C., Campioni, M., Chittilapilly, E., Basu, R., Toffolo, G., Cobelli, C., & Rizza, R. (2006) · Diabetes · doi:10.2337/db06-0319 · Cited by 230
Self-citationMotivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223 · cited 2×
“It has been established that the ability of glucose to entrain ultradian insulin secretion patterns is disturbed in diabetic and prediabetic individuals [157]–[159], but the exact role of oscillations in the glucose regulation systems is still under investigation [160].”
Pulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223 · cited 2×
“Specific to diabetes, it has been reported that insulin secretion patterns are more irregular in healthy older and obese individuals and patients with prediabetes or type II diabetes mellitus than in young, nonobese, nondiabetic subjects [156]–[159].”
Lilly lecture 1989. Toward physiological understanding of glucose tolerance. Minimal-model approach
Bergman, R. N. (1989) · Diabetes · doi:10.2337/diabetes.38.12.1512 · Cited by 215 · cited 3×
“Only later this remote compartment was experimentally proven in dog studies to be the interstitial fluid [27].”
An Improved PID Switching Control Strategy for Type 1 Diabetes
Marchetti, G., Barolo, M., Jovanovic, L. G., Zisser, H., & Seborg, D. E. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915665 · Cited by 212 · cited 2×
“this direction by [261], where the authors present a controller”
Daniel, S., Noda, M., Straub, S. G., & Sharp, G. W. G. (1999) · Diabetes · doi:10.2337/diabetes.48.9.1686 · Cited by 210
Evaluating the Efficacy of Closed-Loop Glucose Regulation via Control-Variability Grid Analysis
Magni, L., Raimondo, D. M., Man, C. D., Breton, M. D., Patek, S. D., Nicolao, G. D., Cobelli, C., & Kovatchev, B. P. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200414 · Cited by 207 · cited 4×
“Preliminary to a clinical study, the controller can be applied to an in silico population, representative of the real population, and the performance assessed on the CVGA.”
InfluentialSelf-citationRun-to-Run Control in Semiconductor Manufacturing
(2010) · CRC Press eBooks · doi:10.1201/9781420040661 · Cited by 206 · cited 1×
“This type of problem, called run-to-run (R2R) control, has been extensively studied in the control of chemical and manufacturing processes [293].”
Oerter, K. E., Guardabasso, V., & Rodbard, D. (1986) · Computers and Biomedical Research · doi:10.1016/0010-4809(86)90014-5 · Cited by 204
Nonparametric input estimation in physiological systems: Problems, methods, and case studies
Nicolao, G. D., Sparacino, G., & Cobelli, C. (1997) · Automatica · doi:10.1016/s0005-1098(96)00254-3 · Cited by 204 · cited 1×
“, the stochastic deconvolution method [62].”
Self-citationTracer Kinetics in Biomedical Research
Cobelli, C., Foster, D., & TOFFOLO, G. M. (2002) · Springer eBooks · doi:10.1007/b112199 · Cited by 201
Self-citationDalla Man, C., Caumo, A., Basu, R., Rizza, R., Toffolo, G., & Cobelli, C. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00319.2003 · Cited by 198 · cited 1×
“has been precisely estimated and has been validated by comparison with both multiple tracer [46] and glucose clamp [47] techniques.”
Self-citationMetabolic and electrical oscillations: partners in controlling pulsatile insulin secretion
Bertram, R., Sherman, A., & Satin, L. S. (2007) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00359.2007 · Cited by 198
Model-based blood glucose control for type 1 diabetes via parametric programming
Dua, V., Doyle, F. J., & Pistikopoulos, E. N. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878075 · Cited by 198
Validation of the Archimedes Diabetes Model
Eddy, D. M., & Schlessinger, L. (2003) · Diabetes Care · doi:10.2337/diacare.26.11.3102 · Cited by 192 · cited 1×
“However, in this review we have to limit our scope; thus, we will not be able to discuss modeling in the areas of patient management [9], [10] and health care intervention strategies [11]–[14], or in the emerging area of systems biology [15], [16].”
Roles of Glucose Transport and Glucose Phosphorylation in Muscle Insulin Resistance of NIDDM
Bonadonna, R. C., Bonora, E., Prato, S. D., Saccomani, M. P., Cobelli, C., Natali, A., Frascerra, S., Pecori, N., Ferrannini, E., Bier, D., et al. (1996) · Diabetes · doi:10.2337/diab.45.7.915 · Cited by 191
Self-citationModel predictive control of glucose concentration in type I diabetic patients: An in silico trial
Magni, L., Raimondo, D., Man, C., Nicolao, G. D., Kovatchev, B., & Cobelli, C. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.04.003 · Cited by 190 · cited 30×
“Finally, there may be constraints on the manipulated variables (insulin delivery rates by the pump is greater than zero and less than some maximal value) (50) (51) and also on the controlled ones (glycemia in the admissible range) (52) The rationale behind MPC is rather simple: at each time point we compute the sequen…”
InfluentialSelf-citationBode, B. W., Gross, K. M., Rikalo, N., Schwartz, S. L., Wahl, T. O., Page, C. W., Gross, T. M., & Mastrototaro, J. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731285 · Cited by 190 · cited 2×
“These methods have rapidly evolved from a concept [238] to implementation in CGM devices, such as the GuardianRT (Medtronic, Norhtridge, CA) [239] and the Freestyle Navigator (Abbott Diabetes Care, Alameda, CA) [178].”
Models of subcutaneous insulin kinetics. A critical review
Nucci, G., & Cobelli, C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00071-7 · Cited by 189 · cited 1×
“modeled and quantitative models exist [142], [285], [286] which allowed both the estimation of the timing and duration of insulin”
Self-citationClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185 · cited 4×
“This can be done for both PID regulators [261] and MPC ones [143], [255]–[257].”
InfluentialSelf-citationAn integrated mathematical model of the dynamics of blood glucose and its hormonal control
Cobelli, C., Federspil, G., Pacini, G., Salvan, A., & Scandellari, C. (1982) · Mathematical Biosciences · doi:10.1016/0025-5564(82)90050-5 · Cited by 182
Self-citationA Mathematical Model of the Glucose-tolerance test
Ackerman, E., Rosevear, J. W., & McGuckin, W. F. (1964) · Physics in Medicine and Biology · doi:10.1088/0031-9155/9/2/307 · Cited by 179 · cited 1×
“With various minor modifications this model has been used in conjunction with intravenous injections or infusions [29]–[31] and also during an oral glucose tolerance test [32]–[34] to obtain a four-parameter representation of glucose metabolism in various states of glucose intolerance, including diabetes.”
Modeling Phasic Insulin Release
Nesher, R., & Cerasi, E. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s53 · Cited by 179 · cited 1×
“for granules having different thresholds [149], but Grodsky”
Two-Hour Seven-Sample Oral Glucose Tolerance Test and Meal Protocol
Dalla Man, C., Campioni, M., Polonsky, K. S., Basu, R., Rizza, R. A., Toffolo, G., & Cobelli, C. (2005) · Diabetes · doi:10.2337/diabetes.54.11.3265 · Cited by 179
Self-citationAnalysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors
Breton, M. D., & Kovatchev, B. P. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200517 · Cited by 178
Self-citationEstimating false-positive and false-negative errors in analyses of hormonal pulsatility
Cauter, E. V. (1988) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1988.254.6.e786 · Cited by 177
Modelling Methodology for Physiology and Medicine
(2014) · Elsevier eBooks · doi:10.1016/c2012-0-06031-0 · Cited by 176
Cobelli, C., Toffolo, G., & Ferrannini, E. (1984) · Mathematical Biosciences · doi:10.1016/0025-5564(84)90114-7 · Cited by 171 · cited 5×
“Glucose kinetics requires at least a two compartment description [21].”
InfluentialSelf-citationβ-Cell Function Across the Spectrum of Glucose Tolerance in Obese Youth
Weiss, R., Caprio, S., Trombetta, M., Taksali, S. E., Tamborlane, W. V., & Bonadonna, R. C. (2005) · Diabetes · doi:10.2337/diabetes.54.6.1735 · Cited by 165 · cited 2×
“Hepatic insulin extraction can then be calculated from SR and profiles [106].”
Kanderian, S. S., Weinzimer, S., Voskanyan, G., & Steil, G. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300508 · Cited by 165 · cited 1×
“Although the confidence in their results is certainly higher than that obtained using as simulator the glucose minimal model [25] (extensively misused for this purpose and recently being the core of the Medtronic Virtual Patient [139]), the impact has been very modest.”
Bolus Calculator: A Review of Four “Smart” Insulin Pumps
Zisser, H., Robinson, L., Bevier, W. C., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L. G. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0284 · Cited by 164 · cited 1×
“An alternative approach relies on insulin-on-board (IOB) computation [251].”
Estimation of Future Glucose Concentrations with Subject-Specific Recursive Linear Models
Eren-Oruklu, M., Çinar, A., Quinn, L., & Smith, D. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0065 · Cited by 164 · cited 1×
“eling techniques [227]–[233], but neural networks [234], [235] and other physiological structural models [236] have been used”
Closing the Loop: The Adicol Experience
Hovorka, R., Chassin, L. J., Wilinska, M. E., Canonico, V., Akwi, J. A., Federici, M. O., Massi‐Benedetti, M., Hutzli, I., Zaugg, C., Kaufmann, H., et al. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774197990 · Cited by 153
Ellingsen, C., Dassau, E., Zisser, H., Grosman, B., Percival, M. W., Jovanovic, L. G., & Doyle, F. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300319 · Cited by 153 · cited 1×
“certain safety constraints already within the real-time control module [258], [269].”
A Closed-Loop Artificial Pancreas Using Model Predictive Control and a Sliding Meal Size Estimator
Lee, H., Buckingham, B., Wilson, D., & Bequette, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300511 · Cited by 150 · cited 3×
“context, a meal detection and estimation module [258], [276],”
Wang, Y., Dassau, E., & Doyle, F. J. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2024409 · Cited by 150
Metabolic Syndrome and Robustness Tradeoffs
Kitano, H., Oda, K., Kimura, T., Matsuoka, Y., CSETE, M. E., Doyle, J. C., & Muramatsu, M. (2004) · Diabetes · doi:10.2337/diabetes.53.suppl_3.s6 · Cited by 148 · cited 1×
“However, in this review we have to limit our scope; thus, we will not be able to discuss modeling in the areas of patient management [9], [10] and health care intervention strategies [11]–[14], or in the emerging area of systems biology [15], [16].”
Bock, G., Chittilapilly, E. G., Basu, R., TOFFOLO, G. M., Cobelli, C., Chandramouli, V., Landau, B. R., & Rizza, R. A. (2007) · Diabetes · doi:10.2337/db06-1776 · Cited by 148
Self-citationInterstitial fluid glucose dynamics during insulin-induced hypoglycaemia
Steil, G. M., Rebrin, K., Hariri, F., Jinagonda, S., Tadros, S. S., Darwin, C. H., & Saad, M. F. (2005) · Diabetologia · doi:10.1007/s00125-005-1852-x · Cited by 148
Kovatchev, B. P., Cox, D. J., Kumar, A., Gonder-Frederick, L. A., & Clarke, W. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322527021 · Cited by 146 · cited 2×
“The LBGI, which is based on the left branch of the BG Risk Function r(BG) has been validated as an excellent predictor of future significant hypoglycemia [186], [187].”
Self-citationA minimal model of insulin secretion and kinetics to assess hepatic insulin extraction.
Toffolo, G., Campioni, M., Basu, R., Rizza, R., & Cobelli, C. (2006) · American Journal of Physiology. Endocrinology and Metabolism · doi:10.1152/ajpendo.00473.2004 · Cited by 145 · cited 1×
“In addition, from pre- and post-hepatic model parameters an index of hepatic extraction can also be calculated [108], [109].”
Self-citationPostprandial Suppression of Glucagon Secretion Depends on Intact Pulsatile Insulin Secretion
Meier, J. J., Kjems, L. L., Veldhuis, J. D., Lefèbvre, P., & Butler, P. C. (2006) · Diabetes · doi:10.2337/diabetes.55.04.06.db05-1449 · Cited by 144 · cited 1×
“ApEn has been utilized to probe the regulation of several hormones including growth hormone [175], aldosterone [176], cortisol [177], insulin [178], and glucagon [179].”
Detection of a Meal Using Continuous Glucose Monitoring
Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J. (2008) · Diabetes Care · doi:10.2337/dc07-1293 · Cited by 143 · cited 1×
“context, a meal detection and estimation module [258], [276],”
Cobelli, C., Pacini, G., TOFFOLO, G. M., & Saccà, L. (1986) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1986.250.5.e591 · Cited by 140 · cited 1×
“, -glucose) label, was first interpreted with one [48]–[51] and, subsequently, with a two-compartment minimal model [52], [53], [55], [56] which has been shown to be more accurate.”
Self-citationBruttomesso, D., Farret, A., Costa, S., Marescotti, M. C., Vettore, M., Avogaro, A., Tiengo, A., Man, C. D., Place, J., Facchinetti, A., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300504 · Cited by 140
Self-citationCobelli, C., & Mari, A. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442625 · Cited by 140
Self-citationHirsch, I. B., Armstrong, D. U., Bergenstal, R. M., Buckingham, B. A., Childs, B. P., Clarke, W. L., Peters, A. L., & Wolpert, H. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0016 · Cited by 135 · cited 1×
“CGM [191]–[193] and charted guidelines for clinical use [194] and its future as a precursor to closed-loop control [195].”
TOFFOLO, G. M., Grandi, F. D., & Cobelli, C. (1995) · Diabetes · doi:10.2337/diab.44.7.845 · Cited by 134
Self-citationAndreassen, S., Benn, J. J., Hovorka, R., Olesen, K. G., & Carson, E. R. (1994) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(94)90052-3 · Cited by 133
Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B. A., Cobry, E. C., Clinton, P. K., Gage, V., Caswell, K., Kunselman, E. L., Cameron, F., & Chase, H. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0032 · Cited by 132 · cited 1×
“This approach has been shown to reduce the risk of nocturnal hypoglycemia [242], [250].”
O'Meara, N. M., Sturis, J., Van Cauter, E., & Polonsky, K. S. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116560 · Cited by 132
Prediction of Severe Hypoglycemia
Cox, D. J., Gonder-Frederick, L., Ritterband, L., Clarke, W., & Kovatchev, B. P. (2007) · Diabetes Care · doi:10.2337/dc06-1386 · Cited by 129
Self-citationPredicting Subcutaneous Glucose Concentration in Humans: Data-Driven Glucose Modeling
Gani, A., Gribok, A. V., Rajaraman, S., Ward, W. K., & Jaques Reifman, A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005937 · Cited by 129 · cited 1×
“eling techniques [227]–[233], but neural networks [234], [235] and other physiological structural models [236] have been used”
Basu, A., Dalla Man, C., Basu, R., Toffolo, G., Cobelli, C., & Rizza, R. A. (2009) · Diabetes Care · doi:10.2337/dc08-1826 · Cited by 129
Self-citationKowalski, A. J. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0031 · Cited by 128 · cited 1×
“Recently, it has been proposed that implementation of “semi closed-loop” glucose control, only using the safety module, without the real-time control, could offer a first step towards full-closed loop control [253].”
Insulin sensitivity by oral glucose minimal models: validation against clamp.
Man, C. D., Yarasheski, K., Caumo, A., Robertson, H., Toffolo, G., Polonsky, K., & Cobelli, C. (2005) · American Journal of Physiology. Endocrinology and Metabolism · doi:10.1152/ajpendo.00076.2005 · Cited by 128 · cited 3×
“has been validated against the multiple tracer [57] and the glucose clamp [47] techniques.”
Self-citationDevelopment of a Neural Network for Prediction of Glucose Concentration in Type 1 Diabetes Patients
Pappada, S. M., Cameron, B. D., & Rosman, P. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200507 · Cited by 125 · cited 1×
“eling techniques [227]–[233], but neural networks [234], [235] and other physiological structural models [236] have been used”
Kovatchev, B. P., Straume, M., Cox, D. J., & Farhy, L. S. (2000) · Computational and Mathematical Methods in Medicine · doi:10.1080/10273660008833060 · Cited by 125 · cited 2×
“27 visualizes this concept by a 72-hour CGM trace of a patient with T1DM: each CGM reading is processed in two steps: 1) application of the symmetrization formula [184], and 2) application of the quadratic risk function that assigns increasing weights to larger BG deviations towards hypo- or hyper-glycemia [185].”
Self-citationCali, A. M. G., Man, C. D., Cobelli, C., Dziura, J., Seyal, A., Shaw, M., Allen, K., Chen, S., & Caprio, S. (2009) · Diabetes Care · doi:10.2337/dc08-1274 · Cited by 125 · cited 1×
“For instance, the battery of oral glucose, C-peptide, and insulin models have been used in studying: the effect of age and gender on glucose metabolism [59]; the effect of anti-aging drugs [110]; the influence of ethnicity [111]; insulin sensitivity and beta-cell function in nondiabetic [112] and obese [113] adolescen…”
Self-citationVicini, P., Caumo, A., & Cobelli, C. (1997) · American Journal of Physiology. Endocrinology and Metabolism · doi:10.1152/ajpendo.1997.273.5.e1024 · Cited by 124 · cited 3×
“, -glucose) label, was first interpreted with one [48]–[51] and, subsequently, with a two-compartment minimal model [52], [53], [55], [56] which has been shown to be more accurate.”
Self-citationPredictive Monitoring for Improved Management of Glucose Levels
Jaques Reifman, A., Rajaraman, S., Gribok, A. V., & Ward, W. K. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100405 · Cited by 123 · cited 2×
“Furthermore, the prediction algorithm of [228] has been”
Diabetes mellitus modeling and short-term prediction based on blood glucose measurements
Ståhl, F. L., & Johansson, R. (2008) · Mathematical Biosciences · doi:10.1016/j.mbs.2008.10.008 · Cited by 122 · cited 1×
“eling techniques [227]–[233], but neural networks [234], [235] and other physiological structural models [236] have been used”
Evaluation of Factors Affecting CGMS Calibration
Diabetes Research In Children Network (Direcnet) Study Group (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.318 · Cited by 116 · cited 1×
“[200], analyzed the improvement in CGMS sensor accuracy”
The cost-effectiveness of different management strategies for Type I diabetes: a Swiss perspective
Palmer, A. J., Weiss, C., Sendi, P., Neeser, K., Brandt, A., Singh, G., Wenzel, H., & Spinas, G. A. (2000) · Diabetologia · doi:10.1007/s001250050003 · Cited by 115 · cited 1×
“However, in this review we have to limit our scope; thus, we will not be able to discuss modeling in the areas of patient management [9], [10] and health care intervention strategies [11]–[14], or in the emerging area of systems biology [15], [16].”
A run-to-run control strategy to adjust basal insulin infusion rates in type 1 diabetes
Palerm, C. C., Zisser, H., Jovanovic, L. G., & Doyle, F. J. (2007) · Journal of Process Control · doi:10.1016/j.jprocont.2007.07.010 · Cited by 113 · cited 1×
“The first applications to glucose control regarded the iterative adjustment of the basal and boluses forming the conventional open-loop therapy [280]–[282].”
Toffolo, G., Breda, E., Cavaghan, M. K., Ehrmann, D. A., Polonsky, K. S., & Cobelli, C. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.1.e2 · Cited by 112 · cited 1×
“[104] during “up&down” intravenous glucose infusion and by Steil et al.”
Self-citationStable-Label Intravenous Glucose Tolerance Test Minimal Model
Avogaro, A., Bristow, J., Bier, D., Cobelli, C., & Toffolo, G. (1989) · Diabetes · doi:10.2337/diab.38.8.1048 · Cited by 107
Self-citationA Mathematical Model for the Glucose Induced Insulin Release in Man
Cerasi, E., Fick, G. H., & Rudemo, M. (1974) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.1974.tb00403.x · Cited by 107
Entrainment of pulsatile insulin secretion by oscillatory glucose infusion.
Sturis, J., Cauter, E. V., Blackman, J. D., & Polonsky, K. S. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115015 · Cited by 106 · cited 1×
“Peakdetection methods provide information on pulse amplitude and location [161]–[164], while spectral/correlation analysis seeks to identify cycles in time series [165], [166].”
Run-to-Run Tuning of Model Predictive Control for Type 1 Diabetes Subjects: In Silico Trial
Magni, L., Forgione, M., Toffanin, C., Man, C. D., Kovatchev, B. P., Nicolao, G. D., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300512 · Cited by 106 · cited 3×
“More recently, R2R control has been applied also to the tuning of the controller parameters [254] where adjustment of the controller aggressiveness is considered.”
Self-citationTillil, H., Shapiro, E. T., Miller, M. A., Karrison, T., Frank, B. H., Galloway, J. A., Rubenstein, A. H., & Polonsky, K. S. (1988) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1988.254.3.e349 · Cited by 105
Compartmental Analysis in Biology and Medicine, 2nd edition.
Faddy, M. J., & Jacquez, J. A. (1987) · Biometrics · doi:10.2307/2531562 · Cited by 104 · cited 1×
“Multiple tracer dilution data can be interpreted with both linear distributed parameter (see reviews [18] and [71] and compartmental organ models [72].”
Silber, H. E., Jauslin, P. M., Frey, N., Gieschke, R., Simonsson, U. S. H., & Karlsson, M. O. (2007) · The Journal of Clinical Pharmacology · doi:10.1177/0091270007304457 · Cited by 103
A simulation model of glucose regulation in the critically ill
Hovorka, R., Chassin, L. J., Ellmerer, M., Plank, J., & Wilinska, M. E. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/8/008 · Cited by 102 · cited 1×
“In view of this, another inclusion criterion is the validation platform: we will only consider control algorithms validated in clinical in vivo trials or in advanced in silico experiments, which provide accurate description of dynamic phenomena and/or incorporate interindividual variability [137], [244], [245].”
Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy
Salzsieder, E., Albrecht, G., Fischer, U., & Freyse, E. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325500 · Cited by 101
Caumo, A., & Cobelli, C. (1993) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1993.264.5.e829 · Cited by 101 · cited 1×
“, -glucose) label, was first interpreted with one [48]–[51] and, subsequently, with a two-compartment minimal model [52], [53], [55], [56] which has been shown to be more accurate.”
Self-citationCretti, A., Lehtovirta, M., Bonora, E., Brunato, B., Zenti, M., Tosi, F., Caputo, M., Caruso, B., Groop, L., Muggeo, M., et al. (2001) · European Journal of Clinical Investigation · doi:10.1046/j.1365-2362.2001.00827.x · Cited by 99 · cited 2×
“[100] describes insulin secretion with the static component of glucose control of the C-peptide minimal model; thus, it is characterized by a delay but does not include any dynamic, i.”
Glucose Transport in Human Skeletal Muscle: The In Vivo Response to Insulin
Bonadonna, R., Saccomani, M., Seely, L., Zych, K., Ferrannini, E., Cobelli, C., & DeFronzo, R. (1993) · Diabetes · doi:10.2337/diab.42.1.191 · Cited by 99 · cited 1×
“Consequently, this model allowed us to study the enhancing effect of insulin on muscle glucose transport parameters in nondiabetic subjects [73] and identified the presence of a localized defect in insulin control in non-insulin-dependent diabetic (NIDD) patients [74].”
Self-citationEl-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Jonkers, F. C., & Henquin, J. (2001) · Diabetes · doi:10.2337/diabetes.50.3.540 · Cited by 99 · cited 3×
“Later, Jonkers and Henquin [150] showed that the number of active cells is a sigmoidal function of the glucose concentration, as assumed by Grodsky [120] or the threshold distribution.”
InfluentialRun-to-Run Control in Semiconductor Manufacturing
Drain, D. C. (2002) · Journal of Quality Technology · doi:10.1080/00224065.2002.11980181 · Cited by 99
Multiple tracer dilution estimates of D- and 2-deoxy-D-glucose uptake by the heart
Kuikka, J. T., Levin, M., & Bassingthwaighte, J. B. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.250.1.h29 · Cited by 98 · cited 2×
“The only application to glucose metabolism of distributed parameter models has been in an isolated and perfused heart [70].”
Minimal modeling, partition analysis, and the estimation of insulin sensitivity.
Bergman, R. N., & Cobelli, C. (1980) · PubMed · Cited by 98
Self-citationQuon, M. J., Cochran, C., Taylor, S. I., & Eastman, R. C. (1994) · Diabetes · doi:10.2337/diab.43.7.890 · Cited by 96 · cited 1×
“, using one instead of two compartments during the highly dynamic IVGTT perturbation, can introduce bias in glucose effectiveness and insulin sensitivity, being over- and under-estimated, respectively [38]–[40].”
Disorderly and nonstationary insulin secretion in relatives of patients with NIDDM
Schmitz, O., Pørksen, N. K., Nyholm, B., Skjærbæk, C. B., Butler, P. C., Veldhuis, J. D., & Pincus, S. M. (1997) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1997.272.2.e218 · Cited by 95 · cited 2×
“It has been established that the ability of glucose to entrain ultradian insulin secretion patterns is disturbed in diabetic and prediabetic individuals [157]–[159], but the exact role of oscillations in the glucose regulation systems is still under investigation [160].”
The Extended Kalman Filter for Continuous Glucose Monitoring
Knobbe, E. J., & Buckingham, B. A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.15 · Cited by 95 · cited 2×
“was done by Knobbe and Buckingham [201].”
Siragy, H. M., Vieweg, W. V. R., Pincus, S. M., & Veldhuis, J. D. (1995) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.80.1.7829626 · Cited by 95 · cited 1×
“ApEn has been utilized to probe the regulation of several hormones including growth hormone [175], aldosterone [176], cortisol [177], insulin [178], and glucagon [179].”
Hypoglycemia Prediction and Detection Using Optimal Estimation
Palerm, C. C., Willis, J. P., Desemone, J., & Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.3 · Cited by 94 · cited 1×
“In particular, it can be used to predict hypoglycemia [274], [275] and possibly trigger safety”
van den Berg, G., Pincus, S. M., Veldhuis, J. D., Frölich, M., & Roelfsema, F. (1997) · European Journal of Endocrinology · doi:10.1530/eje.0.1360394 · Cited by 93 · cited 1×
“ApEn has been utilized to probe the regulation of several hormones including growth hormone [175], aldosterone [176], cortisol [177], insulin [178], and glucagon [179].”
Garg, S. K., Smith, J. G. W., Beatson, C. R., Lopez-Baca, B., Voelmle, M. K., & Gottlieb, P. A. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0109 · Cited by 93
Undermodeling affects minimal model indexes: insights from a two-compartment model
Caumo, A., Vicini, P., Zachwieja, J. J., Avogaro, A., Yarasheski, K. E., Bier, D. M., & Cobelli, C. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.6.e1171 · Cited by 92 · cited 1×
“For instance, in [122] and [123] the consequences of undermodeling the glucose system by using the classic IVGTT single compartment minimal model has been studied by using a richer IVGTT two compartment glucose-insulin simulation model.”
Self-citationGraphical and Numerical Evaluation of Continuous Glucose Sensing Time Lag
Kovatchev, B. P., Shields, D., & Breton, M. D. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0044 · Cited by 91 · cited 1×
“of the direction of BG change [196], [207], [208].”
Self-citationThe kinetics of insulin in man. I. General aspects
Ferrannini, E., & Cobelli, C. (1987) · Diabetes/Metabolism Reviews · doi:10.1002/dmr.5610030201 · Cited by 90 · cited 2×
“In the physiological concentration range (up to 100–150 U/ml) where insulin kinetic is approximately linear, various linear compartmental models have been proposed [84], following the landmark model of Sherwin et al.”
Self-citationHovorka, R., Chassin, L. J., Luzio, S. D., Playle, R., & Owens, D. R. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.3.4646 · Cited by 90
Palerm, C. C., & Bequette, B. W. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100505 · Cited by 89
Impact of pulsatility on the ensemble orderliness (approximate entropy) of neurohormone secretion
Veldhuis, J. D., Johnson, M. L., Veldhuis, O. L., Straume, M., & Pincus, S. M. (2001) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2001.281.6.r1975 · Cited by 88 · cited 1×
“, in hormone secretion studies, the discrimination power of ApEn from plasma concentration time series can be influenced by their kinetics [180], [181].”
Meneilly, G. S., Ryan, A. S., Veldhuis, J. D., & Elahi, D. (1997) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.82.12.4457 · Cited by 87 · cited 1×
“It has been established that the ability of glucose to entrain ultradian insulin secretion patterns is disturbed in diabetic and prediabetic individuals [157]–[159], but the exact role of oscillations in the glucose regulation systems is still under investigation [160].”
Pendergrass, M., Bertoldo, A., Bonadonna, R., Nucci, G., Mandarino, L., Cobelli, C., & DeFronzo, R. A. (2007) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00617.2005 · Cited by 87 · cited 2×
“Among these, it was possible to show that the insulin control on both transmembrane transport and phosphorylation flux in subjects affected by NIDDM is much less efficient with respect to nondiabetic subjects [76], [77].”
Self-citationBertoldo, A., Peltoniemi, P., Oikonen, V., Knuuti, J. M., Nuutila, P., & Cobelli, C. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.281.3.e524 · Cited by 86 · cited 1×
“In order to provide rate constants of transport and phosphorylation of F FDG in skeletal muscle, a four-compartment model (plasma, extracellular, tissue F FDG, and F FDG ) with five rate constants has been proposed [81].”
Self-citationValidation of simple and complex models in physiology and medicine
Cobelli, C., Carson, E. R., Finkelstein, L., & Leaning, M. S. (1984) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1984.246.2.r259 · Cited by 86 · cited 1×
“Although strategies for validation of a complex (versus simple) model have been delineated [17], [119], the difficulties of the problem remain.”
Self-citationPatek, S. D., Bequette, B. W., Breton, M. D., Buckingham, B. A., Dassau, E., Doyle, F. J., Lum, J. W., Magni, L., & Zisser, H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300207 · Cited by 84
Self-citationControl to Range for Diabetes: Functionality and Modular Architecture
Kovatchev, B. P., Patek, S. D., Dassau, E., Doyle, F. J., Magni, L., Nicolao, G. D., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300509 · Cited by 83 · cited 2×
“In order to classify and organize the review of the literature, we refer to a recent paper that has proposed a layered architecture for artificial pancreas systems [249] (Fig.”
Self-citationCobelli, C., & Ruggeri, A. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325203 · Cited by 82
Self-citationIntroduction to Modeling in Physiology and Medicine
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-160240-6.x5001-7 · Cited by 80 · cited 4×
“Although strategies for validation of a complex (versus simple) model have been delineated [17], [119], the difficulties of the problem remain.”
InfluentialThe Future of Continuous Glucose Monitoring: Closed Loop
Hovorka, R. (2008) · Current Diabetes Reviews · doi:10.2174/157339908785294479 · Cited by 80 · cited 1×
“CGM [191]–[193] and charted guidelines for clinical use [194] and its future as a precursor to closed-loop control [195].”
An Integrated Glucose‐Insulin Model to Describe Oral Glucose Tolerance Test Data in Type 2 Diabetics
Jauslin, P. M., Silber, H. E., Frey, N., Gieschke, R., Simonsson, U. S. H., Jorga, K. M., & Karlsson, M. O. (2007) · The Journal of Clinical Pharmacology · doi:10.1177/0091270007302168 · Cited by 80
Finegood, D. T., & Tzur, D. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.3.e485 · Cited by 80
Run-to-Run Control of Meal-Related Insulin Dosing
Zisser, H., Jovanovič, L., Doyle, F., Ospina, P., & Owens, C. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.48 · Cited by 78 · cited 1×
“The first applications to glucose control regarded the iterative adjustment of the basal and boluses forming the conventional open-loop therapy [280]–[282].”
A stochastic deconvolution method to reconstruct insulin secretion rate after a glucose stimulus
Sparacino, G., & Cobelli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488799 · Cited by 76 · cited 1×
“Deconvolution methods have been applied to estimate the secretion profile in various physiological states [89], [90] and during both intravenous and oral glucose tolerance tests [91]–[93].”
Self-citationKovatchev, B. P., Cox, D. J., Farhy, L. S., Straume, M., Gonder-Frederick, L. A., & Clarke, W. L. (2000) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.85.11.6999 · Cited by 76 · cited 1×
“0, respectively [187], and has been used for short term prediction of hypoglycemia as well [188], [189].”
Self-citationCobelli, C., Bettini, F., Caumo, A., & Quon, M. J. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.6.e1031 · Cited by 74 · cited 1×
“, using one instead of two compartments during the highly dynamic IVGTT perturbation, can introduce bias in glucose effectiveness and insulin sensitivity, being over- and under-estimated, respectively [38]–[40].”
Self-citationEffect of input excitation on the quality of empirical dynamic models for type 1 diabetes
Finan, D. A., Palerm, C. C., Doyle, F. J., Seborg, D. E., Zisser, H., Bevier, W. C., & Jovanovič, L. (2009) · AIChE Journal · doi:10.1002/aic.11699 · Cited by 73 · cited 1×
“of the inputs [254], [266] (see also [267] for further optimal de-”
A Biopsychobehavioral Model of Risk of Severe Hypoglycemia
Gonder-Frederick, L. A., Cox, D. J., Kovatchev, B. P., Schlundt, D. G., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.4.661 · Cited by 71
Self-citationContinuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71 · cited 1×
“measurement [216]–[219] and may be reaching a physiological”
Self-citationHollingdal, M., Juhl, C. B., Pincus, S. M., Sturis, J., Veldhuis, J. D., Polonsky, K. S., Pørksen, N., & Schmitz, O. (2000) · Diabetes · doi:10.2337/diabetes.49.8.1334 · Cited by 71
Facchinetti, A., Sparacino, G., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100504 · Cited by 69 · cited 1×
“models have been studied as well [204], [205].”
Self-citationGillis, R., Palerm, C. C., Zisser, H., Jovanovic, L., Seborg, D., & Doyle, F. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100605 · Cited by 67 · cited 1×
“servation are needed (see [143], [273], and [292]).”
Fridlyand, L. E., Harbeck, M. C., Roe, M. W., & Philipson, L. H. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00555.2006 · Cited by 65
Stefania Montani, B., Magni, P., Bellazzi, R., Larizza, C., Roudsari, A., & Carson, E. R. (2003) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(03)00045-9 · Cited by 65 · cited 1×
“However, in this review we have to limit our scope; thus, we will not be able to discuss modeling in the areas of patient management [9], [10] and health care intervention strategies [11]–[14], or in the emerging area of systems biology [15], [16].”
Panteleon, A. E., Loutseiko, M., Steil, G. M., & Rebrin, K. (2006) · Diabetes · doi:10.2337/db05-1346 · Cited by 65
Wilinska, M. E., Budiman, E. S., Taub, M. B., Elleri, D., Allen, J. M., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300514 · Cited by 65 · cited 3×
“This can be done for both PID regulators [261] and MPC ones [143], [255]–[257].”
King, C., Anderson, S. M., Breton, M. D., Clarke, W. L., & Kovatchev, B. P. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100302 · Cited by 65 · cited 1×
“models have been studied as well [204], [205].”
Self-citationProbabilistic Evolving Meal Detection and Estimation of Meal Total Glucose Appearance
Cameron, F., Niemeyer, G., & Buckingham, B. A. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300505 · Cited by 64 · cited 1×
“[277] could greatly help the controller reacting properly to the”
Cengiz, E., Swan, K. L., Tamborlane, W. V., Steil, G. M., Steffen, A. T., & WEINZIMER, S. A. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0102 · Cited by 64 · cited 1×
“This approach has been shown to reduce the risk of nocturnal hypoglycemia [242], [250].”
Srinivasan, R., Kadish, A. H., & Sridhar, R. (1970) · Computers and Biomedical Research · doi:10.1016/0010-4809(70)90021-2 · Cited by 64 · cited 1×
“, for assessing different control algorithms and different insulin infusion routes [122], [127]–[138].”
Continuous Glucose Monitoring with Glucose Sensors: Calibration and Assessment Criteria
Lodwig, V., & Heinemann, L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322250596 · Cited by 64
Five-compartment model of insulin kinetics and its use to investigate action of chloroquine in NIDDM
Hovorka, R., Powrie, J., Smith, G. D., Sönksen, P. H., Carson, E. R., & Jones, R. H. (1993) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1993.265.1.e162 · Cited by 64 · cited 1×
“[86], which also incorporates a description of insulin kinetic at the receptor level.”
Steil, G. M., Hwu, C.-M., Janowski, R., Hariri, F., Jinagouda, S. D., Darwin, C. H., Tadros, S. S., Rebrin, K., & Saad, M. F. (2004) · Diabetes · doi:10.2337/diabetes.53.5.1201 · Cited by 63 · cited 1×
“[105] for describing hyperglycemic clamp C-peptide data as well as meals, thus providing further independent evidence for its validity.”
Breda, E., Toffolo, G., Polonsky, K., & Cobelli, C. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s227 · Cited by 62 · cited 1×
“In particular, both a rate of change of glucose component of insulin secretion and a delay between glucose stimulus and beta-cell response have been shown to be necessary to fit the data [103].”
Self-citationAn Online Self-Tunable Method to Denoise CGM Sensor Data
Facchinetti, A., Sparacino, G., & Cobelli, C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033264 · Cited by 62 · cited 2×
“Monte Carlo simulation of [225] and obtained by adding,”
Self-citationMan, C. D., Bock, G., Giesler, P. D., Serra, D. B., Ligueros‐Saylan, M., Foley, J. E., Camilleri, M., TOFFOLO, G. M., Cobelli, C., Rizza, R. A., et al. (2008) · Diabetes Care · doi:10.2337/dc08-1512 · Cited by 62
Self-citationSaccomani, M. P., Bonadonna, R. C., Bier, D. M., DeFronzo, R. A., & Cobelli, C. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.270.1.e170 · Cited by 62
Self-citation
Flagged first, then by citations
Research works printed but not linked: 15
- 10.1210/jc.80.1.28 · DOI
- 10.1210/jc.81.10.3746 · DOI
- patek, 2007, Adaptive meal detection algorithm enabling closed-loop control in type 1 diabetes, Proc Diabetes Technology Meeting
- 10.1210/jc.82.12.4088 · DOI
- 10.1210/jc.84.6.1938 · DOI
- bassingthwaighte, 1984, Handbook of Physiology The Cardiovascular System Microcirculation
- utriainen, 1998, Lumped constant for [14C]deoxy-D-glucose in human skeletal muscle, Diabetologia, 41, 187a
- palerm, 2005, Hypoglycemia prediction and detection using optimal estimation, Diabetes Technol Therapeutics, 7, 3, 10.1089/dia.2005.7.3 · DOI
- 10.1177/193229680700100505 · DOI
- dalla man, 2009, A pre & type 2 diabetes simulator for in silico trials, Proc Ninth Diabetes Technology Meeting
- pickup, 1991, Textbook of Diabetes, 2
- denti, 2009, A nonlinear mixed-effects approach to the estimation of the glucose disposition index, Proc PAGE 2009 Meeting
- toffolo, 2001, Quantitative indexes of beta-cell function during graded up&down glucose infusion from C-peptide minimal models, Amer J Physiol Endocrinol Metab, 280, 2e, 10.1152/ajpendo.2001.280.1.E2 · DOI · Paper page
- patek, 2009, Control of hypoglycemia via estimation of active insulin, glucose forecasts, and risk-based insulin reduction, Proc 2nd Advanced Technol Treatment for Diabetes
- 2009, Nonlinear Model Predictive Control Towards New Challenging Applications, 384
Cited by
Sorted by citations
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Self-citationArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Specification-Based Monitoring of Cyber-Physical Systems: A Survey on Theory, Tools and Applications
Bartocci, E., Deshmukh, J. V., Donzé, A., Fainekos, G., Maler, O., Ničković, D., & Sankaranarayanan, S. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-75632-5_5 · Cited by 333
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Self-citation
Metadata
- Authors
- Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P.
- Affiliations
- University of Padua (IT)
- University of Pavia (IT)
- University of Virginia (US)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2009
- Volume
- 2
- Pages
- 54-96
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- PMC
- PMC2951686
- OpenAlex
- W2171613573
- Cited by
- 511
- References
- 304
- Citations by year
- 2026: 13 · 2025: 27 · 2024: 11 · 2023: 17 · 2022: 25 · 2021: 27 · 2020: 32 · 2019: 27 · 2018: 39 · 2017: 42 · 2016: 29 · 2015: 40 · 2014: 44 · 2013: 39 · 2012: 43
- FWCI
- 24.04
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01-DK-051562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- diabetes management, computer simulation, artificial pancreas, feedback control, continuous glucose monitoring, modular control architecture
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review