Flexible Sensors for Chronic Wound Management
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Chronic nonhealing wounds are a major source of morbidity and mortality in bed-ridden and diabetic patients. Monitoring of physical and chemical parameters important in wound healing and remodeling process can be of immense benefit for optimum management of such lesions. Low-cost flexible polymeric and paper-based substrates are attractive platforms for fabrication of such sensors. In this review, we discuss recent advances in flexible physiochemical sensors for chronic wound monitoring. After a brief introduction to wound healing process and commercial wound dressings, we describe various flexible biocompatible substrates that can be used as the base platform for integration of wound monitoring sensors. We will then discuss several fabrication methods that can be utilized to integrate physical and chemical sensors onto such substrates. Finally, we will present physical and chemical sensors developed for monitoring wound microenvironment and outline future development venues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of Poly(Lactic Acid)
Garlotta, D. (2001) · Journal of Polymers and the Environment · doi:10.1023/a:1020200822435 · Cited by 3,707
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · cited 1×
“electrodes [95] as well as completely biodegradable electronic circuits [see Fig.”
BackgroundA Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286 · cited 1×
“These include: (a) PDMS [51], (b) Parylene-C [66], (c) polyimide [71], (d) paper [131], (e) silk [96], and (f) Parylene-C/PDMS bilayer [60].”
Health properties of resistant starch
Nugent, A. P. (2005) · Nutrition Bulletin · doi:10.1111/j.1467-3010.2005.00481.x · Cited by 715 · cited 1×
“(PVA), starch [93], [94], and silk can serve as structural materials that dissolve in water [see Fig.”
BackgroundFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · cited 1×
“More recently, they have been widely used as flexible substrates in biomedical and chemical sensors [67]–[70].”
BackgroundA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Water vapor permeability of biodegradable polymers
Shogren, R. (1997) · Journal of environmental polymer degradation · doi:10.1007/bf02763592 · Cited by 287
Bioabsorbable implant material review
Maurus, P. B., & Kaeding, C. C. (2004) · Operative Techniques in Sports Medicine · doi:10.1053/j.otsm.2004.07.015 · Cited by 280 · cited 1×
“the fabrication of paper-based systems for biomedical application such as controlled drug delivery, tissue engineering, sutures, biodegradable vascular grafts [83], [84], low-cost microfluidics”
LaVan, F. B., & Hunt, T. K. (1990) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)30621-0 · Cited by 273
Cited by
Drug delivery systems and materials for wound healing applications
Saghazadeh, S., Rinoldi, C., Schot, M., Kashaf, S. S., Sharifi, F., Jalilian, E., Nuutila, K., Giatsidis, G., Mostafalu, P., Derakhshandeh, H., et al. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.04.008 · Cited by 842
Advanced Hydrogels as Wound Dressings
Tavakoli, S., & Klar, A. S. (2020) · Biomolecules · doi:10.3390/biom10081169 · Cited by 544
Fabrication Methods for Microfluidic Devices: An Overview
Scott, S., & Ali, Z. (2021) · Micromachines · doi:10.3390/mi12030319 · Cited by 479
Wireless chemical sensors and biosensors: A review
Kassal, P., Steinberg, M. D., & Steinberg, I. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.074 · Cited by 308
Flexible pH‐Sensing Hydrogel Fibers for Epidermal Applications
Tamayol, A., Akbari, M., Zilberman, Y., Comotto, M., Lesha, E., Serex, L., Bagherifard, S., Chen, Y., Fu, G., Ameri, S. K., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500553 · Cited by 262
Brown, M. S., Ashley, B., & Koh, A. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00047 · Cited by 227
“…process or that fail to demonstrate improvement through treatment under the normal physiological tissue repair mechanism in a timely manner, present severe difficulties for individuals afflicted with this condition and a substantial financial burden for the healthcare industry (Ochoa et al., 2014).”
BackgroundInfluentialSmart Bandage With Wireless Strain and Temperature Sensors and Batteryless NFC Tag
Escobedo, P., Bhattacharjee, M., Nikbakhtnasrabadi, F., & Dahiya, R. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3048282 · Cited by 209
“temperature [23]–[25], uric acid [21], [26], moisture [27], oxygen [28], [29], lactate [29], pressure and strain [30]–[33], and others [14], [15], [34], [35].”
BackgroundThe design, fabrication, and applications of flexible biosensing devices
Xu, M., Obodo, D., & Yadavalli, V. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.019 · Cited by 208
“on soft tissue) to deliver accurate, reliable and real-time measurement of physiological parameters or biomarkers (Fernandez et al. 2015; Liu et al. 2016; Ochoa et al. 2014).”
BackgroundPal, A., Goswami, D., Cuellar, H. E., Castro, B., Kuang, S., & Martinez, R. V. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.060 · Cited by 173
Metadata
- Authors
- Ochoa, M., Rahimi, R., & Ziaie, B.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2014
- Volume
- 7
- Pages
- 73-86
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W1981716096
- Cited by
- 95
- References
- 14
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.