Abstract
The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at home. Oscillometry is one of the most common measurement methods used in automated BP monitors. A review of the literature shows that a large variety of oscillometric algorithms have been developed for accurate estimation of BP but these algorithms are scattered in many different publications or patents. Moreover, considering that oscillometric devices dominate the home BP monitoring market, little effort has been made to survey the underlying algorithms that are used to estimate BP. In this review, a comprehensive survey of the existing oscillometric BP estimation algorithms is presented. The survey covers a broad spectrum of algorithms including the conventional maximum amplitude and derivative oscillometry as well as the recently proposed learning algorithms, model-based algorithms, and algorithms that are based on analysis of pulse morphology and pulse transit time. The aim is to classify the diverse underlying algorithms, describe each algorithm briefly, and discuss their advantages and disadvantages. This paper will also review the artifact removal techniques in oscillometry and the current standards for the automated BP monitors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The systolic and diastolic BPs are estimated using proprietary algorithms, for example, based on empirical fixed-ratio coefficients [50, 53] that are designed to coincide with BPs measured by an auscultation sphygmomanometer.”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
In the citing paper
“However, the range of optimal coefficients for accurate systolic and diastolic BP measurements varies greatly between devices [12, 45, 50, 54].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
(2002) · The Lancet · doi:10.1016/s0140-6736(02)11911-8 · Cited by 10,266 · cited 1×
“A recent 1-million-patient metaanalysis suggests that a 3–4 mmHg increase in systolic BP would translate into 20% higher stroke mortality and a 12% higher mortality from ischemic heart disease [33].”
BackgroundMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 2×
“Bland and Altman applied their assessment approach on BP data in [192] and [193].”
BackgroundMethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333 · cited 1×
“[5], 20% of adults in”
Neuro-Fuzzy and Soft Computing: A Computational Approach to Learning and Machine Intelligence
Jang, J. R., & Sun, C. (1996) · Cumulative Index of Computer Aided Architectural Design · Cited by 4,601
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Research works printed but not linked: 13
- 2009, Non-Invasive Sphygmomanometers – Part 2 Clinical Validation of Automated Measurement Type
- o'brien, 0, The British Hypertension Society protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, 43s
- 2014, IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices
- mattu, 2003, Validation of oscillometric blood pressure measuring devices: A case study of the BpTRU, Master's thesis University of British Columbia
- 2000, Quantifying Uncertainty in Analytical Measurements
- meyer-sabellek, 2011, Blood Pressure Measurements New Techniques in Automatic and in 24-hour Indirect Monitoring
- 2013, Health Survey for England 2012
- 2013, High Blood Pressure—Country Experiences and Effective Interventions Utilized Across the European Region
- 2012, Australian Health Survey First Results
- 2010, QRS onset detector
- gersak, 2006, Oscillometric virtual instrument for blood pressure measurement, Proc 18th IMEKO World Congr, 1
- 10.1016/0301-0511(85)90049-3 · DOI
- 2014, Blood Pressure Measurement Technologies for Low-Resource Settings in the US and India
Cited by
Items 201–228 of 228
Blood pressure measurement algorithm based on hybrid model
Xiao, T., Li, J., & Chen, M. (2025) · doi:10.1117/12.3092946
Vom Modell in die Praxis: Manschettenlose Blutdruckmessung am Finger
Kastinger, H. (2022) · reposiTUm (TU Wien) · doi:10.34726/hss.2022.96866
Lim, P. K. (2020) · University of Malaya Students Repository · doi:10.26190/unsworks/22007
Development of verification framework for a component to be integrated in medical devices
Monga, H. (2024) · Aaltodoc (Aalto University)
Vpliv tlačne povezovalne cevke na meritve gleženjskega indeksa
Pažon, N. (2023) · Repository of the University of Ljubljana (University of Ljubljana)
Richard, C. (2022) · Archipel (Université du Québec à Montréal)
The Challenges and Possibilities of Long-term Self-monitoring of Health
Hailla, S. (2019) · Tampere University Institutional Repository (Tampere University)
Vývoj metodiky kontinuálního neinvazivního měření krevního tlaku
Barvík, D. (2023) · DSpace VŠB-TUO (VŠB-TUO)
Juteau, N. (2020) · Corpus Université Laval (Université Laval)
Investigating multi-wavelength photoplethysmography for hemodynamic monitoring
Sirkiä, J.-P. (2025) · UTUPub (University of Turku)
Лучанко, Р. П. (2023) · ELARTU (Ternopil National Technical University)
Terveystuoli: Vaivattomampia ei-invasiivisia mittauksia terveyden seurantaan
Vapalahti, M. (2018) · Aaltodoc (Aalto University)
Non-invasive Blood Pressure Measurement with Piezoelectric Sensors
Trimech, S., Wolff, C., & Röhrig, C. (2025) · IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS) · doi:10.1109/idaacs68557.2025.11322384
Impact of Blood Pressure Measurement Errors on CVD Risk Prediction in New Zealand
Chandel, T. (2025) · Tuwhera (Auckland University of Technology)
Traitement et Analyse des Signaux Oscillométriques de la Pression Artérielle du Sang.
Benmira, A. M. (2017) · Dépôt Institutionnel de lUniversité de Tlemcen
VYRE: Low-Burden and Robust Oscillometric Ring-Based System for Frequent Blood Pressure Monitoring
Radmehr, A., Seethakantha, S. K., Aziz, A., Tran, Q. T., Nair, A., Saulnier, W., Ganesan, D., & Nguyen, P. (2026) · doi:10.1145/3774906.3802789
Liu, Y., He, Y., Lu, T., Yao, J., Liu, D., Chen, H., & Chi, Q. (2026) · Acta Mechanica Sinica · doi:10.1007/s10409-025-25898-x
Phan, K. D., Lưu, T. T., Le, T. T., Tran-Quang, D.-H., & Huynh, V.-T. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae91f1
Jiang, C., Chen, Y., Zhang, D., Karimi, H. R., & Xu, Y. (2026) · Signal Image and Video Processing · doi:10.1007/s11760-026-05637-3
Al-Ayyad, M. S., Moh’d, B. A.-H., Shamsan, M. H., Ahmad, M. A.-S., Al-Takrouri, M., & Owida, H. A. (2026) · HardwareX · doi:10.1016/j.ohx.2026.e00843
Current evolution and future of blood pressure monitoring
Zafra, M. R. (2026) · UCrea (University of Cantabria)
ANALYSIS OF ECG SIGNALS PROCESSING FOR SMART MEDICAL TECHNOLOGIES
Ulug'bekovich, M. S., Aloviddin, M. I. T. S. O. F., & Abdurasul, A. I. T. S. O. A. (2023) · CENTRAL ASIAN JOURNAL OF MATHEMATICAL THEORY AND COMPUTER SCIENCES · doi:10.51699/cajmtcs.v4i4.428
Non-Pharmacological Interventions in Overcoming Health Problems
Pefbrianti, D., Zubaidah, Pusparina, I., Pramukawati, D. A., & Wardany, N. S. (2023) · International Journal of Community Care of Humanity (IJCCH)
Naudé, D., Smith, W., von Känel, R., & Wentzel, A. (2026) · Journal of Hypertension · doi:10.1097/hjh.0000000000004454
Omari, T., ismael, B. A. J. I., Caulier, F., Rochd, M., & CARLIER, S. G. (2026) · Medical Engineering & Physics · doi:10.1088/1873-4030/aeb805
Hong, J., Lee, B., Jeong, J., & Park, Y.-H. (2026) · Scientific Reports · doi:10.1038/s41598-026-79703-8
A Multimodal and Multichannel Device for Non-invasive Peripheral Vascular Assessment
Lapitan, D., Rogatkin, D., Kapustin, L., Cabal-Mirabal, C., & García-Naranjo, J. C. (2026) · Instruments and Experimental Techniques · doi:10.1134/s0020441226700776
Metadata
- Authors
- Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I.
- Affiliations
- Harvard University (US)
- University of Ottawa (CA)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2015
- Volume
- 8
- Pages
- 44-63
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W1954157498
- Semantic Scholar
- e57de54807d351441397ba571993ae53c65adcd2
- Cited by
- 196
- References
- 187
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 22 · 2023: 19 · 2022: 24 · 2021: 22 · 2020: 26 · 2019: 12 · 2018: 20 · 2017: 17 · 2016: 10 · 2015: 2
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Espace ÉTS (ETS) (submittedVersion)
- Funders
- Ontario Ministry of Training, Colleges and Universities
- Ontario Ministry of Economic Development and Innovation
- Natural Sciences and Engineering Research Council of Canada
- Ontario Centres of Excellence
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- automated blood pressure monitoring, home blood pressure monitoring, learning algorithms, model-based algorithms, pulse transit time, artifact removal
- MeSH terms
- Algorithms, Blood Pressure, Blood Pressure Determination, Humans, Oscillometry, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.