Oscillometric Blood Pressure Estimation: Past, Present, and Future
The DOI matches its Crossref record; 164 of the 187 references it cites were found in a registry or an index.
Abstract
The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at home. Oscillometry is one of the most common measurement methods used in automated BP monitors. A review of the literature shows that a large variety of oscillometric algorithms have been developed for accurate estimation of BP but these algorithms are scattered in many different publications or patents. Moreover, considering that oscillometric devices dominate the home BP monitoring market, little effort has been made to survey the underlying algorithms that are used to estimate BP. In this review, a comprehensive survey of the existing oscillometric BP estimation algorithms is presented. The survey covers a broad spectrum of algorithms including the conventional maximum amplitude and derivative oscillometry as well as the recently proposed learning algorithms, model-based algorithms, and algorithms that are based on analysis of pulse morphology and pulse transit time. The aim is to classify the diverse underlying algorithms, describe each algorithm briefly, and discuss their advantages and disadvantages. This paper will also review the artifact removal techniques in oscillometry and the current standards for the automated BP monitors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The systolic and diastolic BPs are estimated using proprietary algorithms, for example, based on empirical fixed-ratio coefficients [50, 53] that are designed to coincide with BPs measured by an auscultation sphygmomanometer.”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
In the citing paper
“However, the range of optimal coefficients for accurate systolic and diastolic BP measurements varies greatly between devices [12, 45, 50, 54].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
(2002) · The Lancet · doi:10.1016/s0140-6736(02)11911-8 · Cited by 10,266 · cited 1×
“A recent 1-million-patient metaanalysis suggests that a 3–4 mmHg increase in systolic BP would translate into 20% higher stroke mortality and a 12% higher mortality from ischemic heart disease [33].”
BackgroundMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 2×
“Bland and Altman applied their assessment approach on BP data in [192] and [193].”
BackgroundMethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333 · cited 1×
“[5], 20% of adults in”
Neuro-Fuzzy and Soft Computing: A Computational Approach to Learning and Machine Intelligence
Jang, J. R., & Sun, C. (1996) · Cumulative Index of Computer Aided Architectural Design · Cited by 4,601
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Research works printed but not linked: 13
- 2009, Non-Invasive Sphygmomanometers – Part 2 Clinical Validation of Automated Measurement Type
- o'brien, 0, The British Hypertension Society protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, 43s
- 2014, IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices
- mattu, 2003, Validation of oscillometric blood pressure measuring devices: A case study of the BpTRU, Master's thesis University of British Columbia
- 2000, Quantifying Uncertainty in Analytical Measurements
- meyer-sabellek, 2011, Blood Pressure Measurements New Techniques in Automatic and in 24-hour Indirect Monitoring
- 2013, Health Survey for England 2012
- 2013, High Blood Pressure—Country Experiences and Effective Interventions Utilized Across the European Region
- 2012, Australian Health Survey First Results
- 2010, QRS onset detector
- gersak, 2006, Oscillometric virtual instrument for blood pressure measurement, Proc 18th IMEKO World Congr, 1
- 10.1016/0301-0511(85)90049-3 · DOI
- 2014, Blood Pressure Measurement Technologies for Low-Resource Settings in the US and India
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“Over the past 20 to 30 years, the oscillometric technique, wherein software within a device evaluates the oscillometric waveforms, commonly during BP cuff deflation, and uses algorithms to estimate BP, has been developed and refined.(15) Regardless of who is measuring BP or the method used (eg, auscultatory or oscillo…”
MethodA Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
Chen, S., Wu, N., Lin, S., Duan, J., Xu, Z., Pan, Y., Zhang, H., Xu, Z., Huang, L., Hu, B., et al. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.104460 · Cited by 196
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Flexible and wearable capacitive pressure sensor for blood pressure monitoring
Bijender, & Kumar, A. (2021) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2021.100434 · Cited by 115
Kalehoff, J. P., & Oparil, S. (2020) · Current Hypertension Reports · doi:10.1007/s11906-020-01077-7 · Cited by 108
Salman, O. H., Taha, Z. K., Alsabah, M. Q., Hussein, Y. S., Mohammed, A. S., & Aal-Nouman, M. I. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106357 · Cited by 102
Peng, C., Chen, M., Sim, H. K., Zhu, Y., & Jiang, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3021923 · Cited by 103
Bijender, & Kumar, A. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113770 · Cited by 98
Barvik, D., Černý, M., Penhaker, M., & Noury, N. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3109643 · Cited by 90
Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84
Formulas to Explain Popular Oscillometric Blood Pressure Estimation Algorithms
Chandrasekhar, A., Yavarimanesh, M., Hahn, J.-O., Sung, S.-H., Chen, C.-H., Cheng, H.-M., & Mukkamala, R. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01415 · Cited by 84
“The derivative algorithm estimates diastolic BP and systolic BP as the external pressures at which the oscillogram has maximum and minimum slope, respectively (Drzewiecki and Bronzino, 2006; Forouzanfar et al., 2015).”
BackgroundAdvances in Non-Invasive Blood Pressure Measurement Techniques
Panula, T., Sirkiä, J., Wong, D., & Kaisti, M. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3141877 · Cited by 82
Empowering Technology Enabled Care Using IoT and Smart Devices: A Review
Baali, H., Djelouat, H., Amira, A., & Bensaali, F. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2786301 · Cited by 63
An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners
Ringrose, J. S., Polley, G., McLean, D., Thompson, A., Morales, F., & Padwal, R. (2017) · American Journal of Hypertension · doi:10.1093/ajh/hpx041 · Cited by 64
Kumar, V. S., & Krishnamoorthi, C. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112582 · Cited by 70
A non-invasive continuous cuffless blood pressure estimation using dynamic Recurrent Neural Networks
Şentürk, Ü., Polat, K., & Yücedağ, İ. (2020) · Applied Acoustics · doi:10.1016/j.apacoust.2020.107534 · Cited by 69
History and Justification of a National Blood Pressure Measurement Validated Device Listing
Cohen, J. B., Padwal, R. S., Gutkin, M. C., Green, B. B., Bloch, M. J., Germino, F. W., Sica, D. A., Viera, A. J., Bluml, B. M., White, W. B., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11990 · Cited by 65
Alghamdi, A., Polat, K., Alghoson, A., Alshdadi, A. A., & El‐Latif, A. A. A. (2020) · Applied Acoustics · doi:10.1016/j.apacoust.2020.107256 · Cited by 65
Association of Fatal and Nonfatal Cardiovascular Outcomes With 24-Hour Mean Arterial Pressure
Melgarejo, J. D., Yang, W., Thijs, L., Li, Y., Asayama, K., Hansen, T. W., Wei, F., Kikuya, M., Ohkubo, T., Dolan, E., et al. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14929 · Cited by 57
Alghamdi, A., Polat, K., Alghoson, A., Alshdadi, A. A., & El‐Latif, A. A. A. (2020) · Applied Acoustics · doi:10.1016/j.apacoust.2020.107279 · Cited by 56
Physics-informed neural networks for parameter estimation in blood flow models
Garay, J., Dunstan, J., Uribe, S. A., & Costabal, F. S. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108706 · Cited by 55
Lamptey, P., Laar, A., Adler, A. J., Dirks, R., Caldwell, A., Prieto-Merino, D., Aerts, A., Pearce, N., & Perel, P. (2017) · BMC Public Health · doi:10.1186/s12889-017-4260-5 · Cited by 53
An instrument for measuring blood pressure and assessing cardiovascular health from the fingertip
Panula, T., Koivisto, T., Pänkäälä, M., Niiranen, T., Kantola, I. M., & Kaisti, M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112483 · Cited by 52
Noninvasive Blood Pressure Estimation Using Ultrasound and Simple Finite Element Models
Zakrzewski, A. M., & Anthony, B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2714666 · Cited by 51
Perioperative blood pressure monitoring
Roach, J. K., & Thiele, R. H. (2019) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2019.05.001 · Cited by 48
Qin, K., Huang, W. X., Zhang, T., & Tang, S. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-022-10353-8 · Cited by 49
Benmira, A. M., Pérez‐Martin, A., Schuster, I., Aichoun, I., Coudray, S., Bereksi-Reguig, F., & Dauzat, M. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1128821 · Cited by 48
Efektivitas Isometric Handgrip Exercise dalam Menurunkan Tekanan Darah pada Pasien Hipertensi
Zainuddin, R., & Labdullah, P. (2020) · JURNAL ILMIAH KESEHATAN SANDI HUSADA · doi:10.35816/jiskh.v12i2.364 · Cited by 45
Dynamic Harmonic Analysis With FIR Filters Designed With O-Splines
Serna, J. A. D. L. O. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2996976 · Cited by 44
Argha, A., Celler, B. G., & Lovell, N. H. (2020) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3040715 · Cited by 45
Mamun, M. M. R. K., & Sherif, A. (2022) · Bioengineering · doi:10.3390/bioengineering10010027 · Cited by 44
Argha, A., & Celler, B. G. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2941037 · Cited by 43
Cuff-based blood pressure measurement: challenges and solutions
Pilz, N., Picone, D. S., Patzak, A. R., Opatz, O. S., Lindner, T., Fesseler, L., Heinz, V., & Bothe, T. L. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2402368 · Cited by 44
GMM-HMM-Based Blood Pressure Estimation Using Time-Domain Features
Celler, B. G., Le, P. N., Argha, A., & Ambikairajah, E. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2937074 · Cited by 40
Chen, Z., Wang, X., Wang, Z., Zhang, L., Hao, G., Dong, Y., Zhu, M., & Gao, R. (2017) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2017.09.004 · Cited by 39
Deep learning ensemble with asymptotic techniques for oscillometric blood pressure estimation
Lee, S., & Chang, J. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.08.005 · Cited by 33
Argha, A., Wu, J., Su, S. W., & Celler, B. G. (2019) · IEEE Access · doi:10.1109/access.2019.2933498 · Cited by 33
Nitzan, M., Slotki, I. N., & Shavit, L. (2017) · Medical Devices Evidence and Research · doi:10.2147/mder.s141599 · Cited by 30
Kumar, S., Yadav, S., & Kumar, A. (2024) · Sensors & Diagnostics · doi:10.1039/d3sd00201b · Cited by 29
Roy, M. S., Gupta, R., & Sharma, K. D. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3212750 · Cited by 29
Asayama, K., Stolarz‐Skrzypek, K., Yang, W., Hansen, T. W., Brguljan-Hitij, J., Odili, A. N., Li, Y., & Staessen, J. A. (2023) · Hypertension Research · doi:10.1038/s41440-023-01191-4 · Cited by 29
Novel methods of testing and calibration of oscillometric blood pressure monitors
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E. (2018) · PLOS ONE · doi:10.1371/journal.pone.0201123 · Cited by 28
Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor
Bijender, Kumar, S., Soni, A., Yadav, R., Singh, S. P., & Kumar, A. (2024) · ACS Omega · doi:10.1021/acsomega.3c04786 · Cited by 28
Ganesh, G. R. D., Jaidurgamohan, K., Srinu, V., Kancharla, C. R., & Suresh, S. V. S. (2016) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciinfs.2016.8262913 · Cited by 27
Huang, Y., Wang, Z., Zhou, H., Guo, X., Zhang, Y., Wang, Y., Liu, P., Liu, C., Ma, Y., & Zhang, Y. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48973 · Cited by 27
Oscillometric Waveform Evaluation for Blood Pressure Devices
Kumar, S., Yadav, S., & Kumar, A. (2022) · Biomedical Engineering Advances · doi:10.1016/j.bea.2022.100046 · Cited by 26
Development of a wireless blood pressure measuring device with smart mobile device
İlhan, İ., YILDIZ, I., & Kayrak, M. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.11.003 · Cited by 26
Non-contact Blood Pressure Measurement using Doppler Radar based on Waveform Analysis by LSTM
Ishizaka, S., Yamamoto, K., & Ohtsuki, T. O. (2021) · International Conference on Communications · doi:10.1109/icc42927.2021.9500857 · Cited by 25
Cohen, J. B., Wong, T. C., Alpert, B. S., & Townsend, R. R. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.12961 · Cited by 24
Deep Boltzmann Regression With Mimic Features for Oscillometric Blood Pressure Estimation
Lee, S., & Chang, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2734104 · Cited by 23
Liu, J., Sodini, C. G., Ou, Y., Yan, B. P., Zhang, Y., & Zhao, N. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2919896 · Cited by 23
Shaikh, M. R., & Forouzanfar, M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3512197 · Cited by 22
Self-citationLi, Y., Li, F., Li, Y., Cui, X., Li, J., Zhi, H., Wang, W., Sun, Y., & Cui, W. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13902 · Cited by 21
Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
Mugeb, A.-H., Yangirov, M. A., Kolesnikov, D., & Shchukin, S. I. (2021) · Sensors · doi:10.3390/s21248438 · Cited by 22
Argha, A., Celler, B. G., Alinejad‐Rokny, H., & Lovell, N. H. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3217865 · Cited by 20
Effect of porosity and microstructure on the functionality of capacitive pressure sensors
Bijender, & Kumar, A. (2023) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2023.127872 · Cited by 20
Hullender, D. A., & Brown, O. R. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105768 · Cited by 19
Jana, B., Oswal, K., Mitra, S., Saha, G., & Banerjee, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990648 · Cited by 19
Perioperative Hemodynamic Monitoring
de Keijzer, I. N., & Scheeren, T. (2021) · Anesthesiology Clinics · doi:10.1016/j.anclin.2021.03.007 · Cited by 18
Characteristic Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation
Baktash, S., Forouzanfar, M., Batkin, I., Bolić, M., Groza, V. Z., Ahmad, S., & Dajani, H. R. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2594177 · Cited by 17
Self-citationKumar, S., Yadav, S., & Kumar, A. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-023-00856-4 · Cited by 16
High blood pressure prediction based on AAA using J48 classifier
Nimmala, S., Ramadevi, Y., & Chari, K. K. (2018) · International Conference on Signal Processing and Communication Engineering Systems (SPACES) · doi:10.1109/spaces.2018.8316330 · Cited by 16
High blood pressure prediction based on AAA++ using machine-learning algorithms
Nimmala, S., Ramadevi, Y., Sahith, R., & Cheruku, R. (2018) · Cogent Engineering · doi:10.1080/23311916.2018.1497114 · Cited by 16
Feasibility of Precision Medicine in Hypertension Management—Scope and Technological Aspects
Nitzan, M., & Nitzan, I. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12111861 · Cited by 15
Blood pressure monitoring techniques in the natural state of multi-scenes: A review
Liu, Z., Zhou, C., Wang, H., & He, Y. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.851172 · Cited by 15
Alghrairi, M., Farhan, B. A., Ridha, H. M., Mutashar, S., Algriree, W., & Sabbar, B. M. (2024) · Journal of Physics Communications · doi:10.1088/2399-6528/ad7d5d · Cited by 14
Sajgalik, P., Křemen, V., Fabián, V., Maltais, S., Stulak, J. M., Kushwaha, S. S., Joyce, L. D., Schirger, J. A., & Johnson, B. D. (2018) · ASAIO Journal · doi:10.1097/mat.0000000000000775 · Cited by 14
Microcavity assisted graphene pressure sensor for single-vessel local blood pressure monitoring
Luo, J., Wu, J., Zheng, X., Xiong, H., Lin, L., Liu, C., Liu, H., Tang, H., Liu, H., Han, F., et al. (2024) · Nano Research · doi:10.1007/s12274-024-6969-7 · Cited by 13
Liu, I., Liu, F., Zhong, Q., & Ni, S. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01365-w · Cited by 13
Shalom, E., Hirshtal, E., Slotki, I. N., Shavit, L., Yitzhaky, Y., Engelberg, S., & Nitzan, M. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab7b41 · Cited by 13
Juteau, N., & Gosselin, B. J. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3026992 · Cited by 13
Gupta, S., Kakkar, V., Ahmed, S., Khanday, F. A., Sharma, S., Singh, S., & Yoon, B. (2021) · IEEE Access · doi:10.1109/access.2021.3094227 · Cited by 13
Oscillometry-Based Blood Pressure Estimation Using Convolutional Neural Networks
Choi, M., & Lee, S.-J. (2022) · IEEE Access · doi:10.1109/access.2022.3177539 · Cited by 13
Accuracy of cuff blood pressure and systolic blood pressure amplification
Bui, T. V., Picone, D. S., Schultz, M. G., Peng, X., Black, J. A., Dwyer, N., Roberts‐Thomson, P., Adams, H. S. L., Chen, C., Cheng, H., et al. (2023) · Hypertension Research · doi:10.1038/s41440-023-01311-0 · Cited by 12
Agongo, G., Nonterah, E. A., Amenga-Etego, L. N.-K., Debpuur, C. Y., Kaburise, M. B., Ali, S. A., Crowther, N. J., Ramsay, M., & Oduro, A. R. (2020) · International Journal of Hypertension · doi:10.1155/2020/4549031 · Cited by 12
Intelligent Oscillometric System for Automatic Detection of Peripheral Arterial Disease
Forghani, N., Maghooli, K., Dabanloo, N. J., Vasheghani‐Farahani, A., & Forouzanfar, M. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3065379 · Cited by 12
Self-citationZhang, Z., Xi, W., Wang, B., Chu, G. Q., & Wang, F. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13460 · Cited by 12
Koohi, I., Batkin, I., Groza, V. Z., Shirmohammadi, S., Dajani, H. R., & Ahmad, S. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2657978 · Cited by 12
Self-citationBlood Pressure Estimation Using Time Domain Features of Auscultatory Waveforms and Deep Learning
Argha, A., & Celler, B. G. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857464 · Cited by 11
Hybrid Deep Morpho-Temporal Framework for Oscillometric Blood Pressure Measurement
Delfan, N., & Forouzanfar, M. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3310868 · Cited by 11
Self-citationPadwal, R. S., Jalali, A., McLean, D., Anwar, S., Smith, K., Raggi, P., & Ringrose, J. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000356 · Cited by 12
Present and Future Perspectives
Bridge, S., Murtagh, B., & O’Neill, K. (2014) · doi:10.1007/978-1-137-08714-0_5 · Cited by 10
Automated blood pressure measuring devices: how are they clinically validated for accuracy?
Ringrose, J. S., & Padwal, R. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00761-2 · Cited by 9
“The oscillometric technique uses the BP cuff as a sensor to measure and record arterial oscillations generated by arterial pulsations that are converted by a transducer to pressure changes [12].”
MethodTaghiBeyglou, B., Kaufman, J. M., & Fossat, Y. (2024) · IEEE Access · doi:10.1109/access.2024.3443688 · Cited by 9
Uemura, K., Kawada, T., & Sugimachi, M. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865556 · Cited by 9
Penerapan Asihema Therapy untuk Menurunkan Tekanan Darah pada Lansia
Lestari, D. H., Pefbrianti, D., & Ifansyah, M. N. (2023) · Jurnal Abdimas Kesehatan (JAK) · doi:10.36565/jak.v5i1.433 · Cited by 9
Fujiyama, M., Sano, H., Chambers, J. P., & Gieseg, M. A. (2017) · New Zealand Veterinary Journal · doi:10.1080/00480169.2017.1295000 · Cited by 9
An integrated blood pressure measurement system for suppression of motion artifacts
Abderahman, H. N., Dajani, H. R., Bolić, M., & Groza, V. Z. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.007 · Cited by 9
Self-citationComparisons of Oscillometric Blood Pressure Measurements at Different Sites of the Upper Limb
Liu, J., Ou, Y., Yan, B. P., Sodini, C. G., & Zhao, N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512349 · Cited by 9
Benmira, A. M., Pérez‐Martin, A., Coudray, S., Schuster, I., Aichoun, I., Laurent, J., Bereski-Reguig, F., & Dauzat, M. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001252 · Cited by 9
Celler, B. G., Le, P. N., Argha, A., & Ambikairajah, E. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857920 · Cited by 8
Singh, B., Kumar, P., Moulick, P. S., Shankar, S., Kaushik, J., & Sati, A. (2021) · Medical Journal Armed Forces India · doi:10.1016/j.mjafi.2020.12.017 · Cited by 8
The impact of sphygmomanometer placement and cuff placement on blood pressure measurements
Zhu, X., Zhang, P., Huang, W.-Y., Huang, W., Tang, X.-H., Yu, H., & Wang, S. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1388313 · Cited by 7
Hoseinzadeh, M. S., Ekhlasi, A., & Ahmadi, H. (2020) · Iranian Conference on Signal Processing and Intelligent Systems (ICSPIS) · doi:10.1109/icspis51611.2020.9349618 · Cited by 7
Miniaturization of a Finger-Worn Blood Pressure Instrument
Panula, T., Sirkiä, J., & Kaisti, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629790 · Cited by 7
Abderahman, H. N., Dajani, H. R., Bolić, M., & Groza, V. Z. (2016) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533751 · Cited by 7
Self-citationLuchette, M., & Akhondi‐Asl, A. (2024) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003420 · Cited by 6
Quintanar-Gómez, J., Robles-Camarillo, D., Trejo-Macotela, F. R., & Campero-Jurado, I. (2021) · IEEE Latin America Transactions · doi:10.1109/tla.2021.9461853 · Cited by 6
Metadata
- Authors
- Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I.
- Affiliations
- Harvard University (US)
- University of Ottawa (CA)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2015
- Volume
- 8
- Pages
- 44-63
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W1954157498
- Semantic Scholar
- e57de54807d351441397ba571993ae53c65adcd2
- Cited by
- 196
- References
- 187
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 22 · 2023: 19 · 2022: 24 · 2021: 22 · 2020: 26 · 2019: 12 · 2018: 20 · 2017: 17 · 2016: 10 · 2015: 2
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Espace ÉTS (ETS) (submittedVersion)
- Funders
- Ontario Ministry of Training, Colleges and Universities
- Ontario Ministry of Economic Development and Innovation
- Natural Sciences and Engineering Research Council of Canada
- Ontario Centres of Excellence
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- automated blood pressure monitoring, home blood pressure monitoring, learning algorithms, model-based algorithms, pulse transit time, artifact removal
- MeSH terms
- Algorithms, Blood Pressure, Blood Pressure Determination, Humans, Oscillometry, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.