Oscillometric Blood Pressure Estimation: Past, Present, and Future
The DOI matches its Crossref record; 164 of the 187 references it cites were found in a registry or an index.
Abstract
The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at home. Oscillometry is one of the most common measurement methods used in automated BP monitors. A review of the literature shows that a large variety of oscillometric algorithms have been developed for accurate estimation of BP but these algorithms are scattered in many different publications or patents. Moreover, considering that oscillometric devices dominate the home BP monitoring market, little effort has been made to survey the underlying algorithms that are used to estimate BP. In this review, a comprehensive survey of the existing oscillometric BP estimation algorithms is presented. The survey covers a broad spectrum of algorithms including the conventional maximum amplitude and derivative oscillometry as well as the recently proposed learning algorithms, model-based algorithms, and algorithms that are based on analysis of pulse morphology and pulse transit time. The aim is to classify the diverse underlying algorithms, describe each algorithm briefly, and discuss their advantages and disadvantages. This paper will also review the artifact removal techniques in oscillometry and the current standards for the automated BP monitors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The systolic and diastolic BPs are estimated using proprietary algorithms, for example, based on empirical fixed-ratio coefficients [50, 53] that are designed to coincide with BPs measured by an auscultation sphygmomanometer.”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
In the citing paper
“However, the range of optimal coefficients for accurate systolic and diastolic BP measurements varies greatly between devices [12, 45, 50, 54].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [50]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
(2002) · The Lancet · doi:10.1016/s0140-6736(02)11911-8 · Cited by 10,266 · cited 1×
“A recent 1-million-patient metaanalysis suggests that a 3–4 mmHg increase in systolic BP would translate into 20% higher stroke mortality and a 12% higher mortality from ischemic heart disease [33].”
BackgroundMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 2×
“Bland and Altman applied their assessment approach on BP data in [192] and [193].”
BackgroundMethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333 · cited 1×
“[5], 20% of adults in”
Neuro-Fuzzy and Soft Computing: A Computational Approach to Learning and Machine Intelligence
Jang, J. R., & Sun, C. (1996) · Cumulative Index of Computer Aided Architectural Design · Cited by 4,601
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
The Burden of Adult Hypertension in the United States 1999 to 2000: A Rising Tide
Fields, L. E., Burt, V. L., Cutler, J. A., Hughes, J., Roccella, E. J., & Sorlie, P. (2004) · Hypertension · doi:10.1161/01.hyp.0000142248.54761.56 · Cited by 906 · cited 1×
“High BP is a common chronic ailment and represents the primary risk factor for stroke and heart disease [3], [4].”
BackgroundMcDONALD'S BLOOD FLOW IN ARTERIES: THEORETICAL, EXPERIMENTAL AND CLINICAL PRINCIPLES
Czuwala, P. J. (1991) · Echocardiography · doi:10.1111/j.1540-8175.1991.tb01207.x · Cited by 820
O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 772
OʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670 · cited 1×
“can change the shape of the oscillometric pulses [23], [160]– [162].”
BackgroundDetermination of age-related increases in large artery stiffness by digital pulse contour analysis
MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 613
O'Brien, E., Atkins, N., Stergiou, G., Karpettas, N., Parati, G., Asmar, R., Imai, Y., Wang, J., Mengden, T., & Shennan, A. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360e98 · Cited by 610
Digital Filters: Analysis, Design and Applications
Antoniou, A. (1979) · Cited by 535
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 529
Najjar, S. S., Scuteri, A., Shetty, V., Wright, J. G., Muller, D. C., Fleg, J. L., Spurgeon, H. P., Ferrucci, L., & Lakatta, E. G. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.065 · Cited by 496
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · cited 1×
“sphygmomanometer and the low accuracy because of the weak and inconsistent correlation between the PTT and BP [138]– [140].”
BackgroundMeasurement Errors and Uncertainties
(2006) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1007/0-387-29143-1 · Cited by 392
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
Pulse transit time: an appraisal of potential clinical applications
Smith, R. P., Argod, J., Pepin, J.-L., & Levy, P. A. (1999) · Thorax · doi:10.1136/thx.54.5.452 · Cited by 317
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287 · cited 4×
“this assumption, the MAA approximates the MAP as the cuff pressure at which the OMWE attains a maximum [50], [61], [70], [71].”
BackgroundMethodInfluentialFundamental of Nursing: The Art and Science of Nursing Care
Taylor, C., Lillis, C., & LeMone, P. (1990) · Dimensions Of Critical Care Nursing · doi:10.1097/00003465-199001000-00006 · Cited by 286
The Advanced Health and Disaster Aid Network: A Light-Weight Wireless Medical System for Triage
Gao, T., Massey, T., Selavo, L., Crawford, D., Chen, B.-R., Lorincz, K., Shnayder, V., Hauenstein, L., Dabiri, F., Jeng, J., et al. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.910901 · Cited by 268
Coleman, A., Steel, S., Freeman, P., de Greeff, A., & Shennan, A. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282cb57b6 · Cited by 259
Theory of the oscillometric maximum and the systolic and diastolic detection ratios
Drzewiecki, G., Hood, R., & Apple, H. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368225 · Cited by 251
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare
Yoon, Y., Cho, J. H., & Yoon, G. (2009) · Journal of Medical Systems · doi:10.1007/s10916-008-9186-0 · Cited by 198
The Direct and Indirect Measurement of Blood Pressure.
(1970) · Annals of Internal Medicine · doi:10.7326/0003-4819-73-1-152_1 · Cited by 189
Measurements of Young's modulus of elasticity of the canine aorta with ultrasound
Hughes, D. (1979) · Ultrasonic Imaging · doi:10.1016/0161-7346(79)90028-2 · Cited by 189
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179 · cited 6×
“proposed model of oscillometry in [65] was further simplified by performing a global sensitivity analysis and identifying the most significant parameters.”
BackgroundMethodInfluentialBabbs, C. F. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-56 · Cited by 177
A Transducer for the Continuous External Measurement of Arterial Blood Pressure
Pressman, G. L., & Newgard, P. M. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322794 · Cited by 176
Oscillometric blood pressure measurement: progress and problems
van Montfrans, G. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00004 · Cited by 175
Beckett, L., & Godwin, M. (2005) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-5-18 · Cited by 175
van Popele, N. M., Bos, W. J. W., de Beer, N. A. M., van der Kuip, D. A. M., Hofman, A., Grobbee, D. E., & Witteman, J. C. M. (2000) · Hypertension · doi:10.1161/01.hyp.36.4.484 · Cited by 170 · cited 1×
“arterial stiffness [20], and atrial fibrillation [21], [22].”
BackgroundWard, M., & Langton, J. A. (2007) · Continuing Education in Anaesthesia Critical Care & Pain · doi:10.1093/bjaceaccp/mkm022 · Cited by 167
Cattivelli, F. S., & Garudadri, H. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.35 · Cited by 166
Indirect Measurement of Mean Blood Pressure in the Anesthetized Patient
Yelderman, M., & Ream, A. K. (1979) · Anesthesiology · doi:10.1097/00000542-197903000-00022 · Cited by 142
Yamakoshi, K.-I., Shimazu, H., & Togawa, T. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326616 · Cited by 139
Replacing the mercury sphygmomanometer
O'Brien, E. (2000) · BMJ · doi:10.1136/bmj.320.7238.815 · Cited by 113
Pulse Transit Time and Blood Pressure: An Intensive Analysis
Lane, J. D., Greenstadt, L., Shapiro, D., & Rubinstein, E. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb00899.x · Cited by 107
Oscillometric determination of diastolic, mean and systolic blood pressure—A numerical model
Forster, F. K., & Turney, D. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138629 · Cited by 104 · cited 6×
“in [62] to study the effect of different parameters on the cuff pressure oscillations.”
BackgroundMethodInfluentialElectrocardiogram-Assisted Blood Pressure Estimation
Ahmad, S., Chen, S., Soueidan, K., Batkin, I., Bolic, M., Dajani, H., & Groza, V. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2180019 · Cited by 104
Self-citationTHE EFFECT OF BLOOD PRESSURE ALTERATION ON THE PULSE WAVE VELOCITY
Nye, E. R. (1964) · Heart · doi:10.1136/hrt.26.2.261 · Cited by 103
Indirect measurment of arterial blood pressure by Doppler ultrasonic sphygmomanometry
Stegall, H. F., Kardon, M. B., & Kemmerer, W. T. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.6.793 · Cited by 97
(1969) · PubMed · Cited by 96
The mercury sphygmomanometer should be abandoned before it is proscribed
Markandu, N., Whitcher, F., Arnold, A., & Carney, C. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000932 · Cited by 96
Theoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94 · cited 1×
“Therefore, the PTT is modeled with two components: the time taken for the BP pulse wave to arrive from the heart to the brachial artery under the cuff τa(t) and the time taken for the BP pulse wave to travel in the brachial artery underneath the cuff τc(t) [59], [148]”
MethodSurvey of Automated Noninvasive Blood Pressure Monitors
KIM-GAUNG, & SMALL, C. F. (1994) · Journal of Clinical Engineering · doi:10.1097/00004669-199411000-00014 · Cited by 88
Ma, T., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616585 · Cited by 84
Frequency tracking of nonsinusoidal periodic signals in noise
Parker, P. J., & Anderson, B. D. O. (1990) · Signal Processing · doi:10.1016/0165-1684(90)90124-h · Cited by 83
Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring
Pagonas, N., Schmidt, S., Eysel, J., Compton, F., Hoffmann, C., Seibert, F., Hilpert, J., Tschöpe, C., Zidek, W., & Westhoff, T. H. (2013) · Hypertension · doi:10.1161/hypertensionaha.113.01426 · Cited by 81
Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time–Cuff Pressure Dependence
Forouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolic, M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2243148 · Cited by 80
Self-citationAutomated Office Blood Pressure
Myers, M. G., & Godwin, M. S. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2011.09.004 · Cited by 79
Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., & Rajan, S. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2123210 · Cited by 79
Self-citationTakla, G. F., Petre, J. H., Doyle, D. J., Horibe, M., & Gopakumaran, B. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000247964.47706.5d · Cited by 78
Limitations of current validation protocols for home blood pressure monitors for individual patients
Gerin, W., Schwartz, A. R., Schwartz, J. E., Pickering, T. G., Davidson, K. W., Bress, J., OʼBrien, E., & Atkins, N. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200212000-00004 · Cited by 76
McNames, J., & Aboy, M. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910648 · Cited by 75
Reduction of interference in oscillometric arterial blood pressure measurement using fuzzy logic
Lin, C., Liu, S.-H., Wang, J.-J., & Wen, Z. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.809502 · Cited by 74
Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse
Padilla, J. M. S., BERJANO, E. J., Sáiz, J., Fácila, L., Díaz, P. T., & Merce, S. (2006) · Computing in cardiology · Cited by 71
Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements
Pierin, A. M. G., Alavarce, D. C., Gusmão, J. L., Halpern, A., & Mion, D. (2004) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000132425.25263.ac · Cited by 70
Pulse arrival time as a method of obtaining systolic and diastolic blood pressure indirectly
Geddes, L. A., Voelz, M., James, S., & Reiner, D. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442787 · Cited by 65
Stewart, M. J., Gough, K., & Padfield, P. L. (1995) · Journal of Hypertension · doi:10.1097/00004872-199503000-00004 · Cited by 63
Error Mechanisms of the Oscillometric Fixed-Ratio Blood Pressure Measurement Method
Liu, J., Hahn, J., & Mukkamala, R. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0700-7 · Cited by 58
Validation of a method for noninvasive measurement of central arterial pressure.
Sharir, T., Marmor, A. T., Ting, C.-T., Chen, J. W., Liu, C. P., Chang, M.-S., Yin, F. C. P., & Kass, D. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.74 · Cited by 58
Automatic noninvasive measurement of arterial blood pressure
Nitzan, M. (2011) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2011.5704808 · Cited by 56
Umana, E., Ahmed, W., Fraley, M. A., & Alpert, M. A. (2006) · Angiology · doi:10.1177/000331970605700106 · Cited by 56
Effect of respiration, talking and small body movements on blood pressure measurement
Zheng, D., Giovannini, R., & Murray, A. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2011.53 · Cited by 55
Update on Methods & Simulators for Evaluation of Noninvasive Blood Pressure Monitors
NG, K.-G., & SMALL, C. F. (1994) · Journal of Clinical Engineering · doi:10.1097/00004669-199403000-00012 · Cited by 55
Hansen, S. K., & Staber, M. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506000688 · Cited by 54
The Direct and Indirect Measurement of Blood Pressure
P., P. J. (1970) · Journal of The Royal Naval Medical Service · doi:10.1136/jrnms-56-289e · Cited by 53
Evaluation of the correlation between blood pressure and pulse transit time
He, X., Goubran, R. A., & Liu, P. X. (2013) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2013.6549697 · Cited by 52
Instruments and Methods for Calibration of Oscillometric Blood Pressure Measurement Devices
Balestrieri, E., & Rapuano, S. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2050978 · Cited by 52
Lee, S., Chang, J., Nam, S. W., Lim, C., Rajan, S., Dajani, H. R., & Groza, V. Z. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2273612 · Cited by 51
Self-citationForouzanfar, M., Dajani, H. R., Groza, V. Z., Bolić, M., & Rajan, S. (2010) · International Workshop on Soft Computing Applications (SOFA) · doi:10.1109/sofa.2010.5565614 · Cited by 50
Self-citationOn the pressure-volume relationship in circulatory elements
Hardy, H. H., & Collins, R. E. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443403 · Cited by 49
Feghali, R. E., Topouchian, J. A., Pannier, B., Assaad, H. A. E., & Asmar, R. G. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b08367 · Cited by 49
Thompson, A. M., Eguchi, K., Reznik, M. E., Shah, S. S., & Pickering, T. G. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328108f544 · Cited by 48
Lee, S., Bolić, M., Groza, V. Z., Dajani, H. R., & Rajan, S. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2161926 · Cited by 48
Self-citationEffect of tissue mechanical properties on cuff-based blood pressure measurements
Lan, H., Al-Jumaily, A. M., Lowe, A., & Hing, W. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.06.006 · Cited by 47
Assessment of algorithms for oscillometric blood pressure measurement
Chen, S., Groza, V. Z., Bolić, M., & Dajani, H. R. (2009) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2009.5168742 · Cited by 45
Self-citationBarbé, K., Moer, W. V., & Schoors, D. F. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2161933 · Cited by 41
Poon, C. C. Y., Zhang, Y., & Liu, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2006.360098 · Cited by 41
Ball-llovera, A., Rey, R. D., Ruso, R., Ramos, J., Batista, O., & Niubo, I. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280816 · Cited by 40
A survey of validated automated home blood pressure monitors available for the Internet shopper
Graves, J. W. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200504000-00009 · Cited by 39
Zheng, D., Amoore, J., Mieke, S., & Murray, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0694-y · Cited by 39
Development of a new oscillometric blood pressure measurement system
Moraes, J. C. T. B., Cerulli, M., & Ng, P. S. (2003) · Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004) · doi:10.1109/cic.1999.826009 · Cited by 37
Taylor–Fourier Analysis of Blood Pressure Oscillometric Waveforms
Serna, J. A. D. L. O. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2258245 · Cited by 37
Linearizing Oscillometric Blood-Pressure Measurements: (Non)Sense?
Moer, W. V., Lauwers, L., Schoors, D. F., & Barbé, K. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2090703 · Cited by 36
Evaluation of an automated sphygmomanometer for use in the office setting
Myers, M. G., & Valdivieso, M. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283540785 · Cited by 36
Narus, S. P., Egbert, T. P., Lee, T.-K., Lu, J. Z., & Westenskow, D. R. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01616986 · Cited by 35
Blood pressure estimation using oscillometric pulse morphology
Mafi, M., Rajan, S., Bolić, M., Groza, V. Z., & Dajani, H. R. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090691 · Cited by 35
Self-citationForouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolić, M. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2412000 · Cited by 34
Self-citationSorvoja, H. S. S., Myllylä, R. A., Kärjä-Koskenkari, P., Koskenkari, J. K., Lilja, M., & Kesäniemi, Y. A. (2005) · Molecular and Quantum Acoustics · Cited by 33
Amoore, J. N. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000217999.04592.7c · Cited by 32
Soueidan, K., Chen, S., Dajani, H. R., Bolić, M., & Groza, V. F. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/6/881 · Cited by 32
Self-citationRatio-Independent Blood Pressure Estimation by Modeling the Oscillometric Waveform Envelope
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolić, M., Rajan, S., & Batkin, I. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2332239 · Cited by 32
Self-citationBlood pressure estimation using neural networks
Colak, S., & Isik, C. (2005) · IEEE International Conference on Computational Intelligence for Measurement Systems and Applications (CIMSA) · doi:10.1109/cimsa.2004.1397222 · Cited by 32
Multiharmonic tracking using marginalized particle filters
Kim, S., Holmstrom, L. A., & McNames, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649083 · Cited by 30
Verberk, W. J., & de Leeuw, P. W. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.46 · Cited by 29
Noninvasive Arterial Blood Pressure and Mechanics
Drzewiecki, G. M. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.ch71 · Cited by 28
Palpatory method of measuring diastolic blood pressure
Sahu, D. K., & Bhaskaran, M. (2010) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/0970-9185.74603 · Cited by 28
Using Alternating Kalman Filtering to Analyze Oscillometric Blood Pressure Waveforms
Serna, J. A. D. L. O., Moer, W. V., & Barbé, K. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2258765 · Cited by 27
Zheng, D., Marco, L. Y. D., & Murray, A. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1150-1 · Cited by 27
Oscillometric blood pressure estimation using principal component analysis and neural networks
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolić, M., & Rajan, S. (2009) · IEEE Toronto International Conference Science and Technology for Humanity · doi:10.1109/tic-sth.2009.5444353 · Cited by 27
Self-citationChen, S., Bolić, M., Groza, V. Z., Dajani, H. R., Batkin, I., & Rajan, S. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2092874 · Cited by 25
Self-citationNon-invasive blood pressure data acquisition employing pulse transit time detection
Kerola, J., Kontra, V., & SEPPONEN, R. E. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.652825 · Cited by 24
Automated non-invasive blood pressure devices: are they suitable for use?
Sims, A. J., Menes, J. A., Bousfield, D. R., Reay, C. A., & Murray, A. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000173487.82766.be · Cited by 23
Mathematical modeling and parameter estimation of blood pressure oscillometric waveform
Forouzanfar, M., Balasingam, B., Dajani, H. R., Groza, V. Z., Bolić, M., Rajan, S., & Petriu, E. M. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226639 · Cited by 23
Self-citationSawada, Y., & Yamakoshi, K.-I. (1985) · Biological Psychology · doi:10.1016/0301-0511(85)90049-3 · Cited by 23
Adaptive neuro-fuzzy inference system for oscillometric blood pressure estimation
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolić, M., & Rajan, S. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480225 · Cited by 23
Self-citationJazbinšek, V., Lužnik, J., & Trontelj, Z. (2005) · Cited by 23
Environmental and Behavioral Factors That Can Affect Blood Pressure
Adams, C. E., & Leverland, M. B. (1985) · The Nurse Practitioner · doi:10.1097/00006205-198511000-00005 · Cited by 23
Determination of blood pressure using Bayesian approach
Lee, S., Rajan, S., Dajani, H. R., Groza, V. Z., & Bolić, M. (2011) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2011.5944338 · Cited by 22
Self-citationHypertension: Pathways to Success
Jones, D. W., & Hall, J. E. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.113746 · Cited by 22
Blood pressure estimation using maximum slope of oscillometric pulses
Mafi, M., Rajan, S., Bolić, M., Groza, V. Z., & Dajani, H. R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346655 · Cited by 18
Self-citationTalts, J., Raamat, R., Jagomägi, K., & Kivastik, J. (2011) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-21683-1_18 · Cited by 17
Pulse Wave Velocity in Continuous Blood Pressure Measurements
Meigas, K., Lass, J., Karai, D., Kattai, R., & Kaik, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_144 · Cited by 17
Standard algorithm for blood pressure measurement by sphygmo-oscillographic method
Sapiński, A. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02637026 · Cited by 16
Arterial blood pressure parameter estimation and tracking using particle filters
Balasingam, B., Forouzanfar, M., Bolić, M., Dajani, H. R., Groza, V., & Rajan, S. (2011) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2011.5966739 · Cited by 15
Self-citationImproving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects
Chen, S. (2010) · uO Research (University of Ottawa) · doi:10.20381/ruor-13720 · Cited by 14
Logistic ordinal regression for the calibration of oscillometric blood pressure monitors
Barbé, K., Kurylyak, Y., & Lamonaca, F. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.01.012 · Cited by 13
A novel statistical model for simulation of arterial and intracranial pressure
Aboy, M., McNames, J., Hornero, R., Thong, T., Cuesta, D., Novák, D., & Goldstein, B. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403108 · Cited by 13
Mean arterial pressure estimation method using morphological changes in oscillometric waveform
Song, S., Kim, D. K., Js, L., Chee, Y. J., & Iy, K. (2009) · Computers in Cardiology Conference · Cited by 13
The effect of blood pressure variability on the estimation of the systolic and diastolic pressures
Soueidan, K., Chen, S., Dajani, H. R., Bolić, M., & Groza, V. F. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480215 · Cited by 12
Self-citationA Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation
Forouzanfar, M. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-4926 · Cited by 11
Self-citationAdvanced indirect method for measuring blood pressure
Csordás, P., Mersich, A., & Jobbágy, Á. (2009) · Periodica Polytechnica Electrical Engineering · doi:10.3311/pp.ee.2009-3-4.04 · Cited by 11
Preliminary Study of Motion Artifact Rejection for NIBP measurement in an Ambulance
Koo, Y., Kang, J., Shin, I. H., Jung, M. Y., Suh, G. J., & Kim, H. C. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352388 · Cited by 11
Calibration of Automated Non Invasive Blood Pressure Measurement Devices
Balestrieri, E., & Rapuano, S. (2009) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-05167-8_16 · Cited by 11
Oscillometric blood pressure measurements: A signal analysis
Barbé, K., Moer, W. V., & Lauwers, L. (2010) · Journal of Physics Conference Series · doi:10.1088/1742-6596/238/1/012052 · Cited by 10
Model-based oscillometric blood pressure estimation
Forouzanfar, M., Dajani, H. R., Groza, V. Z., & Bolić, M. (2014) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2014.6860103 · Cited by 10
Self-citationTowards accurate NIBP simulators: Manufacturers' and researchers' contributions
Balestrieri, E., Daponte, P., & Rapuano, S. (2013) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2013.6549713 · Cited by 10
Cardiovascular Signal Decomposition and Estimation with the Extended Kalman Smoother
McNames, J., & Aboy, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260463 · Cited by 10
A statistical model and simulator for cardiovascular pressure signals
Staats, C., Austin, D., & Aboy, M. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim348 · Cited by 9
Estimation of mean blood pressure from oscillometric and manual methods
Zheng, D., & Murray, A. (2008) · Computers in cardiology · doi:10.1109/cic.2008.4749198 · Cited by 9
Taylor-fourier analysis of blood pressure oscillometric waveforms
Serna, J. A. D. L. O. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229147 · Cited by 9
Oscillometric blood pressure pulse morphology
Mafi, M., Bolić, M., Groza, V. Z., Dajani, H. R., & Rajan, S. (2011) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2011.5966753 · Cited by 8
Self-citationAn innovative oscillometric blood pressure measurement: Getting rid of the traditional envelope
Barbé, K., & Moer, W. V. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226634 · Cited by 8
Effects of Deep Breathing on Blood Pressure Measurement in Healthy Subjects
Marco, L. Y. D., Zheng, D., & Murray, A. (2012) · Newcastle University ePrints (Newcastle Univesity) · doi:10.25405/ncl.34197831 · Cited by 7
A model-based retrospective analysis of the fixed-ratio oscillometric blood pressure measurement
Raamat, R., Jagomägi, K., Talts, J., & Kivastik, J. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701577 · Cited by 7
An Investigation Into the Upper Arm Deformation Under Inflatable Cuff
Lan, H., Al‐Jumaily, A. M., & Lowe, A. (2008) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2008-67009 · Cited by 7
Standard calibration procedures for automated non-invasive measurement of blood pressure
Balestrieri, E., & Rapuano, S. (2009) · International Journal of Advanced Media and Communication · doi:10.1504/ijamc.2009.026864 · Cited by 7
Improvement of oscillometric blood pressure estimates through suppression of breathing effects
Chen, S., Bolić, M., Groza, V. Z., Dajani, H. R., Batkin, I., & Rajan, S. (2010) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2010.5488160 · Cited by 7
Self-citation[Oscillometric determination of blood pressure].
Wiinberg, N., Nygart, J., Sengeløv, H., & Pe, N. (1988) · PubMed · Cited by 7
Model-based error analysis of the oscillometric fixed-ratio blood pressure measurement method
Liu, J., Hahn, J., & Mukkamala, R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346011 · Cited by 6
Apparatus and method for electrocardiogram-assisted blood pressure measurement
Batkin, I., Ahmad, S., Bolić, M., Groza, V., Dajani Hilmi, R., & Forouzanfar, M. (2015) · Espace ÉTS (ETS) · Cited by 6
Self-citationTechniques and Applications of Mathematical Modeling for Noninvasive Blood Pressure Estimation
Ursino, M., & Cristalli, C. (2000) · CRC Press eBooks · doi:10.1201/9781420049534.ch-07 · Cited by 5
Biomechanical Basis of Oscillometric Blood Pressure Measuring Technique
Lan, H., Al‐Jumaily, A. M., Hing, W. A., & Lowe, A. (2009) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2009-11857 · Cited by 4
Using Kalman filtering to analyze oscillometric blood pressure waveforms
Serna, J. A. D. L. O., Moer, W. V., & Barbé, K. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226622 · Cited by 4
Hasnain, A., Awan, M. A., & Farooq, M. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03885-3_253 · Cited by 3
McNames, J., Kim, S., & Aboy, M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091159 · Cited by 3
A near-optimum filter for suppressing motion artifact in oscillometric signal
Miller, M., & McEwen, J. A. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.95912 · Cited by 3
Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation
Baktash, S. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-5024 · Cited by 3
Issues in medical measurements
Groza, V. Z. (2011) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2011.5966785 · Cited by 2
Self-citationSimplified Model for the Design of an Oscillometric Blood Pressure Measuring System
James, M. (2012) · The Atrium (University of Guelph) · Cited by 2
Noninvasive Arterial Blood Pressure and Mechanics
(2006) · CRC Press eBooks · doi:10.1201/9781420003864-65 · Cited by 1
Research works printed but not linked: 13
- 2009, Non-Invasive Sphygmomanometers – Part 2 Clinical Validation of Automated Measurement Type
- o'brien, 0, The British Hypertension Society protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, 43s
- 2014, IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices
- mattu, 2003, Validation of oscillometric blood pressure measuring devices: A case study of the BpTRU, Master's thesis University of British Columbia
- 2000, Quantifying Uncertainty in Analytical Measurements
- meyer-sabellek, 2011, Blood Pressure Measurements New Techniques in Automatic and in 24-hour Indirect Monitoring
- 2013, Health Survey for England 2012
- 2013, High Blood Pressure—Country Experiences and Effective Interventions Utilized Across the European Region
- 2012, Australian Health Survey First Results
- 2010, QRS onset detector
- gersak, 2006, Oscillometric virtual instrument for blood pressure measurement, Proc 18th IMEKO World Congr, 1
- 10.1016/0301-0511(85)90049-3 · DOI
- 2014, Blood Pressure Measurement Technologies for Low-Resource Settings in the US and India
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“Over the past 20 to 30 years, the oscillometric technique, wherein software within a device evaluates the oscillometric waveforms, commonly during BP cuff deflation, and uses algorithms to estimate BP, has been developed and refined.(15) Regardless of who is measuring BP or the method used (eg, auscultatory or oscillo…”
MethodA Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
Chen, S., Wu, N., Lin, S., Duan, J., Xu, Z., Pan, Y., Zhang, H., Xu, Z., Huang, L., Hu, B., et al. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.104460 · Cited by 196
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Metadata
- Authors
- Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I.
- Affiliations
- Harvard University (US)
- University of Ottawa (CA)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2015
- Volume
- 8
- Pages
- 44-63
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W1954157498
- Semantic Scholar
- e57de54807d351441397ba571993ae53c65adcd2
- Cited by
- 196
- References
- 187
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 22 · 2023: 19 · 2022: 24 · 2021: 22 · 2020: 26 · 2019: 12 · 2018: 20 · 2017: 17 · 2016: 10 · 2015: 2
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Espace ÉTS (ETS) (submittedVersion)
- Funders
- Ontario Ministry of Training, Colleges and Universities
- Ontario Ministry of Economic Development and Innovation
- Natural Sciences and Engineering Research Council of Canada
- Ontario Centres of Excellence
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- automated blood pressure monitoring, home blood pressure monitoring, learning algorithms, model-based algorithms, pulse transit time, artifact removal
- MeSH terms
- Algorithms, Blood Pressure, Blood Pressure Determination, Humans, Oscillometry, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.