The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Design and Optimization of Printed Spiral Coils for Efficient Transcutaneous Inductive Power Transmission
Abstract
The next generation of implantable high-power neuroprosthetic devices such as visual prostheses and brain computer interfaces are going to be powered by transcutaneous inductive power links formed between a pair of printed spiral coils (PSC) that are batch-fabricated using micromachining technology. Optimizing the power efficiency of the wireless link is imperative to minimize the size of the external energy source, heating dissipation in the tissue, and interference with other devices. Previous design methodologies for coils made of 1-D filaments are not comprehensive and accurate enough to consider all geometrical aspects of PSCs with planar 3-D conductors as well as design constraints imposed by implantable device application and fabrication technology. We have outlined the theoretical foundation of optimal power transmission efficiency in an inductive link, and combined it with semi-empirical models to predict parasitic components in PSCs. We have used this foundation to devise an iterative PSC design methodology that starts with a set of realistic design constraints and ends with the optimal PSC pair geometries. We have executed this procedure on two design examples at 1 and 5 MHz achieving power transmission efficiencies of 41.2% and 85.8%, respectively, at 10-mm spacing. All results are verified with simulations using a commercial field solver (HFSS) as well as measurements using PSCs fabricated on printed circuit boards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microwave Engineering: Land & Space Radiocommunications
Barué, G. (2008) · Wiley eBooks · doi:10.1002/9780470290996 · Cited by 6,159
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Rfid Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification
Finkenzeller, K. (2003) · Thammasat University Digital Collections · Cited by 2,150
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
Sokal, N. O., & Sokal, A. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050582 · Cited by 2,033
Simple accurate expressions for planar spiral inductances
Mohan, S. S., del Mar Hershenson, M., Boyd, S. P., & Lee, T. H. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.792620 · Cited by 1,627
Inductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309
Design of Planar Rectangular Microelectronic Inductors
Greenhouse, H. (1974) · IEEE Transactions on Parts, Hybrids, and Packaging · doi:10.1109/tphp.1974.1134841 · Cited by 1,029
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
CRC Handbook of Biological Effects of Electromagnetic Fields
Polk, C. (2019) · CRC Press eBooks · doi:10.1201/9781351071017 · Cited by 936
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Wheeler, H. A. (1942) · Proceedings of the IRE · doi:10.1109/jrproc.1942.232015 · Cited by 775
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
The design of CMOS radio-frequency integrated circuits, 2nd edition
Lee, T. H. (2004) · Communications Engineer · Cited by 484
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Wiley Encyclopedia of Biomedical Engineering
(2006) · Wiley eBooks · doi:10.1002/9780471740360 · Cited by 368
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Cochlear Implants: Fundamentals and Applications
(2003) · Springer eBooks · doi:10.1007/b97263 · Cited by 292
Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure
Soma, M., Galbraith, D. C., & White, R. L. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326088 · Cited by 265
Designing Efficient Inductive Power Links for Implantable Devices
Harrison, R. R. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378508 · Cited by 244
An optimal design methodology for inductive power link with class-E amplifier
Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.846208 · Cited by 222
Zierhofer, C. M., & Hochmair, E. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55682 · Cited by 214
Analysis of resonant coupled coils in the design of radio frequency transcutaneous links
Donaldson, N. D. N., & Perkins, T. A. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442388 · Cited by 211
Ghovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.905187 · Cited by 202
Self-citationRF powering of millimeter- and submillimeter-sized neural prosthetic implants
Heetderks, W. J. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1388 · Cited by 197
Atluri, S., & Ghovanloo, M. (2006) · 2006 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2006.1692789 · Cited by 196
Self-citationThermal effects of bioimplants
Lazzi, G. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511503 · Cited by 192
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
Ghovanloo, M., & Najafi, K. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903970 · Cited by 151
Self-citationA Modular 32-site wireless neural stimulation microsystem
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837026 · Cited by 151
Self-citationOptimization of inductive RFID technology
Chen, S. C. Q., & Thomas, V. (2002) · Proceedings of the 2001 IEEE International Symposium on Electronics and the Environment. 2001 IEEE ISEE (Cat. No.01CH37190) · doi:10.1109/isee.2001.924506 · Cited by 75
A wireless single-chip telemetry-powered neural stimulation system
Von Arx, J. A., & Najafi, K. (2003) · 1999 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC. First Edition (Cat. No.99CH36278) · doi:10.1109/isscc.1999.759199 · Cited by 74
Akyel, C., Babic, S. I., & Kincic, S. (2002) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2002.803576 · Cited by 70
Atluri, S., & Ghovanloo, M. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419677 · Cited by 67
Self-citationSwitched-capacitor based implantable low-power wireless microstimulating systems
Ghovanloo, M. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693055 · Cited by 57
Self-citationA study of printed spiral coils for neuroprosthetic transcranial telemetry applications
Shah, M. R., Phillips, R. P., & Normann, R. A. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686794 · Cited by 33
Transcutaneous Magnetic Coupling of Power and Data
Ghovanloo, M., & Lazzi, G. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs1372 · Cited by 24
Self-citationReliability in deep brain stimulation
Shill, H. A., & Shetter, A. G. (2005) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2005.858331 · Cited by 8
Kim, S., Wilke, M., Klein, M., Toepper, M., & Solzbacher, F. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369702 · Cited by 8
Cited by
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Self-citationWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Low, Z. N., Chinga, R. A., Tseng, R., & Lin, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2010110 · Cited by 528
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Self-citation
Metadata
- Authors
- Jow, U.-M., & Ghovanloo, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2007-09
- Volume
- 1
- Issue
- 3
- Pages
- 193-202
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2110065276
- Cited by
- 630
- References
- 39
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.