A Low-Power Configurable Neural Recording System for Epileptic Seizure Detection
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This paper describes a low-power configurable neural recording system capable of capturing and digitizing both neural action-potential (AP) and fast-ripple (FR) signals. It demonstrates the functionality of epileptic seizure detection through FR recording. This system features a fixed-gain, variable-bandwidth (BW) front-end circuit and a sigma-delta ADC with scalable bandwidth and power consumption. The ADC employs a 2nd-order single-bit sigma-delta modulator (SDM) followed by a low-power decimation filter. Direct impulse-response implementation of a sinc(3) filter and 8-cycle data pipelining in an IIR filter are proposed for the decimation filter design to improve the power and area efficiency. In measurements, the front end exhibits 39.6-dB DC gain, 0.8 Hz to 5.2 kHz of BW, 5.86- μVrms input-referred noise, and 2.4- μW power consumption in AP mode, while showing 38.5-dB DC gain, 250 to 486 Hz of BW, 2.48- μVrms noise, and 4.5- μW power consumption in FR mode. The noise efficiency factor (NEF) is 2.93 and 7.6 for the AP and FR modes, respectively. At 77-dB dynamic range (DR), the ADC has a peak SNR and SNDR of 75.9 dB and 67 dB, respectively, while consuming 2.75-mW power in AP mode. It achieves 78-dB DR, 76.2-dB peak SNR, 73.2-dB peak SNDR, and 588- μW power consumption in FR mode. Both analog and digital power supply voltages are 2.8 V. The chip is fabricated in a standard 0.6- μm CMOS process. The die size is 11.25 mm(2).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 10-bit 50-MS/s SAR ADC With a Monotonic Capacitor Switching Procedure
Liu, C.-C., Chang, S.-J., Huang, G.-Y., & Lin, Y.-Z. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042254 · Cited by 1,329
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414 · cited 3×
“For both AP and LFP applications, the desired dynamic range can be higher than 60 dB, corresponding to level of input-referred noise for the front-end circuit and high resolution for the ADC [7].”
BackgroundMuller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338 · cited 1×
“[23] presented a DC-coupled neural recording system for spike detection.”
MethodThe Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330 · cited 2×
“In future development, the control of “one-shot” mode can be realized by adding an analog FR-burst detector with adaptive threshold [27] in the front end.”
BackgroundMethodA Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
Self-citationRodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
A Low-Power 0.7 $\mu {\rm V_{rms}}$ 32-Channel Mixed-Signal Circuit for ECoG Recordings
Robinet, S., Audebert, P., Regis, G., Zongo, B., Beche, J.-F., Condemine, C., Filipe, S., & Charvet, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2180835 · Cited by 30 · cited 1×
“This greater than 10 bits resolution is the minimum requirement to achieve acceptable false positive rate, even though the SNR of original IEEG signal is usually less than 15 dB [26].”
Background
Cited by
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
“Sigma-Delta modulators are also utilized in neural recording applications due to the low-frequency bandwidth of neural signals [98,99].”
BackgroundXu, J., Nguyen, A. T., Wu, T., Zhao, W., Luu, D. K., & Yang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2972013 · Cited by 29
Metadata
- Authors
- Qian, C., Shi, J., Parramon, J., & Sanchez-Sinencio, E.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2013-08
- Volume
- 7
- Issue
- 4
- Pages
- 499-512
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2003904738
- Cited by
- 39
- References
- 8
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Low-Power Configurable Neural Recording System for Epileptic Seizure Detection. https://app.cochat.ai/papers/10.1109/tbcas.2012.2228857
- The paper
- Qian, C., Shi, J., Parramon, J., & Sanchez-Sinencio, E. (2013). A Low-Power Configurable Neural Recording System for Epileptic Seizure Detection. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2012.2228857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.