CoChat

A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses

Yi-Kai Lo, Kuanfu Chen, Gad, Parag, Wentai Liu · 2013 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 80

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

This paper presents a fully functionally integrated 1024-channel mixed-mode and mixed-voltage system-on-a-chip (SoC) for epi-retinal and neural prostheses. Taking an AC input, an integrated power telemetry circuits is capable of generating multiple DC voltages with a voltage conversion efficiency of 83% at a load of 100 mW without external diodes or separate power integrated circuits, reducing the form factor of the prosthetic device. A wireless DPSK receiver with a novel noise reduction scheme supports a data rate of 2 Mb/s at a bit-error-rate of 2 ×10⁻⁷. The 1024-channel stimulator array meets an output compliance voltage of ±10 V and provides flexible stimulation waveforms. Through chip-clustering, the stimulator array can be further expanded to 4096 channels. This SoC is designed and fabricated in TSMC 0.18 μm high-voltage 32 V CMOS process and occupies a chip area of 5.7 mm × 6.6 mm. Using this SoC, a retinal implant bench-top test system is set up with real-time visual verification. In-vitro experiment conducted in artificial vitreous humor is designed and set-up to investigate stimulation waveforms for better visual resolution. In our in-vivo experiment, a hind-limb paralyzed rat with spinal cord transection and implanted chronic epidural electrodes has been shown to regain stepping and standing abilities using stimulus provided by the SoC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2013.2297695

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 80

Metadata

Authors
Lo, Y.-K., Chen, K., Gad, P., & Liu, W.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2013-12
Volume
7
Issue
6
Pages
761-772
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2024336262
Cited by
80
References
6
FWCI
4.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses. https://app.cochat.ai/papers/10.1109/tbcas.2013.2297695
The paper
Lo, Y.-K., Chen, K., Gad, P., & Liu, W. (2013). A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2013.2297695

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.