CoChat

Compact Low-Power Cortical Recording Architecture for Compressive Multichannel Data Acquisition

Open access
Shoaran, Mahsa, Kamal, Mahdad Hosseini, Pollo, Claudio, Vandergheynst, Pierre, Schmid, Alexandre · 2014 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 101

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

This paper introduces an area- and power-efficient approach for compressive recording of cortical signals used in an implantable system prior to transmission. Recent research on compressive sensing has shown promising results for sub-Nyquist sampling of sparse biological signals. Still, any large-scale implementation of this technique faces critical issues caused by the increased hardware intensity. The cost of implementing compressive sensing in a multichannel system in terms of area usage can be significantly higher than a conventional data acquisition system without compression. To tackle this issue, a new multichannel compressive sensing scheme which exploits the spatial sparsity of the signals recorded from the electrodes of the sensor array is proposed. The analysis shows that using this method, the power efficiency is preserved to a great extent while the area overhead is significantly reduced resulting in an improved power-area product. The proposed circuit architecture is implemented in a UMC 0.18 [Formula: see text]m CMOS technology. Extensive performance analysis and design optimization has been done resulting in a low-noise, compact and power-efficient implementation. The results of simulations and subsequent reconstructions show the possibility of recovering fourfold compressed intracranial EEG signals with an SNR as high as 21.8 dB, while consuming 10.5 [Formula: see text]W of power within an effective area of 250 [Formula: see text]m × 250 [Formula: see text]m per channel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2014.2304582

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 101

Metadata

Authors
Shoaran, M., Kamal, M. H., Pollo, C., Vandergheynst, P., & Schmid, A.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2014-12
Volume
8
Issue
6
Pages
857-870
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2013024221
Cited by
101
References
11
FWCI
5.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compact Low-Power Cortical Recording Architecture for Compressive Multichannel Data Acquisition. https://app.cochat.ai/papers/10.1109/tbcas.2014.2304582
The paper
Shoaran, M., Kamal, M. H., Pollo, C., Vandergheynst, P., & Schmid, A. (2014). Compact Low-Power Cortical Recording Architecture for Compressive Multichannel Data Acquisition. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2014.2304582

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.