The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
An implant that can electrically stimulate neurons across different depths and regions of the brain currently does not exist as it poses a number of obstacles that need to be solved. In order to address the challenges, this paper presents the concept of "microbead," a fully integrated wirelessly powered neural device that allows for spatially selective activation of neural tissue. The prototype chip is fabricated in 130-nm CMOS technology and currently measures 200 μm × 200 μm, which represents the smallest remotely powered stimulator to date. The system is validated experimentally in a rat by stimulating the sciatic nerve with 195-μs current pulses. To power the ultrasmall on-silicon coil, 36-dBm source power is provided to a highly optimized transmitter (Tx) coil at a coupling distance of 5 mm. In order to satisfy the strict power limit for safe use in human subjects, a pulsed powering scheme is implemented that enables a significant decrease in the average power emitted from the Tx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurodegenerative Diseases Target Large-Scale Human Brain Networks
Seeley, W. W., Crawford, R. K., Zhou, J., Miller, B. L., & Greicius, M. D. (2009) · Neuron · doi:10.1016/j.neuron.2009.03.024 · Cited by 2,350 · cited 1×
“) [14]; ii) revolutionizing our understanding of the brain by studying the correlations between neural networks from different regions of the brain and the mechanisms of cognitive functions (e.”
BackgroundLarge-scale brain networks in cognition: emerging methods and principles
Bressler, S. L., & Menon, V. (2010) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2010.04.004 · Cited by 2,348 · cited 1×
“) [15]; and iii) covering larger area in the sensorimotor cortex of amputees to more accurately control robotic”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“(caused by astrogliosis) around the electrodes [3], [4].”
BackgroundWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 1×
“By getting rid of the centralized and anchored high density MEA, some researchers have demonstrated wirelessly-powered single-channel implants [7], [17]–[19] that have the potential to be scattered all over the brain.”
BackgroundOptimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Restoring the sense of touch with a prosthetic hand through a brain interface
Tabot, G. A., Dammann, J. F., Berg, J. A., Tenore, F. V., Boback, J. L., Vogelstein, R. J., & Bensmaia, S. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221113110 · Cited by 320 · cited 1×
“, finer motor control of the individual fingers) or better evoke a sense of touch [16].”
BackgroundCharthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245 · cited 1×
“neural interfaces [6], [7].”
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218 · cited 1×
“rely on a micro-electrode array (MEA) for a high spatiotemporal resolution interface with the brain [9]–[13].”
BackgroundA review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“[75] 2018 2, 4 MHz 126 25 6 doutT = 35 doutR = 20 [9] 2018 1.”
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Challenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…‘motes’ of a wireless floating microelectrode array (WFMA), such as the neurograin interface [81], [82], the mi-crobead stimulating system [83], and the intraspinal microstimulation (ISMS) network [47], [84], [85], as well as the injectable neural stimulator (InNS) technologies, which…”
Metadata
- Authors
- Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanacevic, M., Thakor, N., & Etienne-Cummings, R.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-06
- Volume
- 12
- Issue
- 3
- Pages
- 521-531
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2792033251
- Cited by
- 76
- References
- 13
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System. https://app.cochat.ai/papers/10.1109/tbcas.2018.2802443
- The paper
- Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanacevic, M., Thakor, N., & Etienne-Cummings, R. (2018). The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2018.2802443
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.