CoChat

A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device

Open access
Jia, Yaoyao, Mirbozorgi, S. Abdollah, Lee, Byunghun, Khan, Wasif, Madi, Fatma, Inan, Omer T., Weber, Arthur, Li, Wen, Ghovanloo, Maysam · 2019 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 68

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

This paper presents a mm-sized, free-floating, wirelessly powered, implantable optical stimulation (FF-WIOS) device for untethered optogenetic neuromodulation. A resonator-based three-coil inductive link creates a homogeneous magnetic field that continuously delivers sufficient power (>2.7 mW) at an optimal carrier frequency of 60 MHz to the FF-WIOS in the near field without surpassing the specific absorption rate limit, regardless of the position of the FF-WIOS in a large brain area. Forward data telemetry carries stimulation parameters by on-off-keying the power carrier at a data rate of 50 kb/s to selectively activate a 4 × 4 μLED array. Load-shift-keying back telemetry controls the wireless power transmission by reporting the FF-WIOS received power level in a closed-loop power control mechanism. LEDs typically require high instantaneous power to emit sufficient light for optical stimulation. Thus, a switched-capacitor-based stimulation architecture is used as an energy storage buffer with one off-chip capacitor to receive charge directly from the inductive link and deliver it to the selected μLED at the onset of stimulation. The FF-WIOS system-on-a-chip prototype, fabricated in a 0.35-μm standard CMOS process, charges a 10-μF capacitor up to 5 V with 37% efficiency and passes instantaneous current spikes up to 10 mA in the selected μLED, creating a bright exponentially decaying flash with minimal wasted power. An in vivo experiment was conducted to verify the efficacy of the FF-WIOS by observing light-evoked local field potentials and immunostained tissue response from the primary visual cortex (V1) of two anesthetized rats.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2918761

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 68

Metadata

Authors
Jia, Y., Mirbozorgi, S. A., Lee, B., Khan, W., Madi, F., Inan, O. T., Weber, A., Li, W., & Ghovanloo, M.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2019-08
Volume
13
Issue
4
Pages
608-618
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2945449319
Cited by
68
References
10
FWCI
2.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device. https://app.cochat.ai/papers/10.1109/tbcas.2019.2918761
The paper
Jia, Y., Mirbozorgi, S. A., Lee, B., Khan, W., Madi, F., Inan, O. T., Weber, A., Li, W., & Ghovanloo, M. (2019). A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2019.2918761

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.