CoChat

Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell

Broekhuyse, Henry M., Nelson, Hill D., Zinman, Bernard, Albisser, A. M. · 1981 · IEEE Transactions on Biomedical Engineering
Cited by 63

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Over the past 15 years, several algorithms have been proposed and used for closed-loop blood glucose regulation. Their intent is to artificially replace the normal responses of the pancreatic beta cell absent in insulin-dependent diabetes. All of these algorithms calculate insulin infusion rates on the basis of minute-by-minute measurements of whole blood glucose concentration and its calculated rate of rise or fall. In addition, various techniques are employed to compensate for measurement delay time and the presence of noise in the measured signals. The goal of these feedback systems is to normalize blood glucose in diabetes mellitus. Interestingly, some recently "optimized" versions provide only a near normalization of glycemia in patients with insulin-dependent diabetes, a degree ofglycemic control which is not significantly different from intensified conventional insulin therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1981.324661

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 24

  1. clemens, 1977, continuous blood glucose analysis and feedback control dynamics for glucose controlled insulin infusion (artificial beta-cell), Proc 14th Int Congr Therapeutics L'Extension Scientifique, 45
  2. clemens, 1977, the development of biostator, a glucose controlled insulin infusion system (gciis), Horm Metab Res Suppl, 7, 22
  3. clemens, 1979, feedback control dynamics for glucose controlled insulin infusion system, Med Progr Technol, 6, 91
  4. fischer, 1978, derivation and experimental proof of a new algorithm for the artificial bcell based on the individual analysis of the physiological insulinglucose relationship, Endokrinologie, 71, 65
  5. 10.1007/BF00290484 · DOI
  6. 10.2337/diab.28.6.558 · doi:10.2337/diab.28.6.558
  7. goriya, 1981, the metabolic and hormonal responses to a mixed meal in unrestrained pancreatectomised dogs chronically treated by portal or peripheral insulin infusion, Diabetolog, 19
  8. grodsky, 1967, Tolbutamide after Ten Years
  9. kadish, 1964, automatic control of blood sugar. i. a servomechanism for glucose monitoring and control, Amer J Med Electron, 3, 82
  10. 10.1007/BF01225463 · DOI
  11. 10.1111/j.0954-6820.1965.tb01810.x · DOI · Paper page
  12. 10.2337/diab.23.5.397 · DOI · Paper page
  13. 10.2337/diab.19.9.644 · DOI · Paper page
  14. 10.1007/BF02573823 · DOI
  15. 10.1109/TBME.1976.324639 · DOI
  16. 1976, Biostator (R) Glucose Controlled Insulin Infusion System Operating Manual
  17. botz, 1979, blood glucose regulation using closed-and open-loop insulin delivery systems. ii. peripheral primed square wave infusions, Diabetolg, 17, 45, 10.1007/BF01222977 · DOI
  18. 10.1109/PROC.1979.11448 · DOI
  19. 10.1530/acta.0.0870339 · DOI
  20. 10.1111/j.1445-5994.1977.tb03687.x · DOI · Paper page
  21. 10.1055/s-0028-1093650 · DOI · Paper page
  22. 10.2337/diabetes.26.7.663 · DOI
  23. 10.2337/diab.27.7.774 · doi:10.2337/diab.27.7.774
  24. 10.1055/s-0028-1093841 · DOI · Paper page

Cited by

See all 63

Metadata

Authors
Broekhuyse, H. M., Nelson, H. D., Zinman, B., & Albisser, A. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1981-10
Volume
BME-28
Issue
10
Pages
678-687
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1990162032
Cited by
63
References
4
FWCI
1.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.