The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Abstract
We have developed a novel method to measure human cardiac pulse at a distance. It is based on the information contained in the thermal signal emitted from major superficial vessels. This signal is acquired through a highly sensitive thermal imaging system. Temperature on the vessel is modulated by pulsative blood flow. To compute the frequency of modulation (pulse), we extract a line-based region along the vessel. Then, we apply fast Fourier transform (FFT) to individual points along this line of interest to capitalize on the pulse's thermal propagation effect. Finally, we use an adaptive estimation function on the average FFT outcome to quantify the pulse. We have carried out experiments on a data set of 34 subjects and compared the pulse computed from our thermal signal analysis method to concomitant ground-truth measurements obtained through a standard contact sensor (piezo-electric transducer). The performance of the new method ranges from 88.52% to 90.33% depending on the clarity of the vessel's thermal imprint. To the best of our knowledge, it is the first time that cardiac pulse has been measured several feet away from a subject with passive means.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
CONDENSATION—Conditional Density Propagation for Visual Tracking
Isard, M., & Blake, A. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008078328650 · Cited by 4,886
The scientist and engineer's guide to digital signal processing
Smith, S. W. (1997) · Cited by 2,799
(1999) · Technometrics · doi:10.1080/00401706.1999.10485691 · Cited by 379
Photoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Characterization of common carotid artery blood-flow waveforms in normal human subjects
Holdsworth, D. W., Norley, C. J. D., Frayne, R., Steinman, D. A., & Rutt, B. K. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/3/301 · Cited by 338
Seeing through the face of deception
Pavlidis, I., Eberhardt, N. L., & Levine, J. A. (2002) · Nature · doi:10.1038/415035a · Cited by 288
Self-citationFundamentals of Anatomy & Physiology
Martini, F. H. (1989) · Medical Entomology and Zoology · Cited by 207
Hint for squint: a computer reliant diagnostic aid for strabismus
Gieszl, L. R., Morris, J. V., & Guyton, D. L. (2005) · Symposium on Computer Applications in Medical Care (SCAMC) · doi:10.1109/scamc.1983.764787 · Cited by 157
Cited by
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“IR thermal imaging employs a highly sensitive camera to likewise measure arterial waveforms from the skin [122], [123].”
BackgroundDetecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.440 · Cited by 553
Improved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
Thermal infrared imaging in psychophysiology: Potentialities and limits
Ioannou, S., Gallese, V., & Merla, A. (2014) · Psychophysiology · doi:10.1111/psyp.12243 · Cited by 367
Self-citationAutomated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
Non-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287
Thermistor at a Distance: Unobtrusive Measurement of Breathing
Fei, J., & Pavlidis, I. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2032415 · Cited by 201
Self-citationA multimodal dataset for various forms of distracted driving
Taamneh, S., Tsiamyrtzis, P., Dcosta, M., Buddharaju, P., Khatri, A., Manser, M., Ferris, T., Wunderlich, R., & Pavlidis, I. (2017) · Scientific Data · doi:10.1038/sdata.2017.110 · Cited by 129
Self-citationCOGCAM: Contact-free Measurement of Cognitive Stress During Computer Tasks with a Digital Camera
McDuff, D. J., Hernandez, J., Gontarek, S., & Picard, R. W. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858247 · Cited by 113
Video based technology for ambient assisted living: A review of the literature
Cardinaux, F., Bhowmik, D., Abhayaratne, C., & Hawley, M. S. (2011) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-2011-0110 · Cited by 98
Remote PPG based vital sign measurement using adaptive facial regions
Tasli, H. E., Gudi, A., & den Uyl, M. (2014) · 2014 IEEE International Conference on Image Processing (ICIP) · doi:10.1109/icip.2014.7025282 · Cited by 99
Pinti, P., Cardone, D., & Merla, A. (2015) · Scientific Reports · doi:10.1038/srep17471 · Cited by 63
Self-citationHong, K., Liu, G., Chen, W., & Hong, S. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2017.12.013 · Cited by 34
Allado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22
Metadata
- Authors
- Garbey, M., Sun, N., Merla, A., & Pavlidis, I.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-08
- Volume
- 54
- Issue
- 8
- Pages
- 1418-1426
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2135220085
- Cited by
- 402
- References
- 21
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.