A Decision-Based Velocity Ramp for Minimizing the Effect of Misclassifications During Real-Time Pattern Recognition Control
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Real-time pattern recognition control is frequently affected by misclassifications. This study investigated the use of a decision-based velocity ramp that attenuated movement speed after a change in classifier decision. The goal was to improve prosthesis positioning by minimizing the effect of unintended movements. Non-amputee and amputee subjects controlled a prosthesis in real-time using pattern recognition. While performing a target achievement test in a virtual environment, subjects had a significantly higher completion rate (p < 0.05) and a more direct path (p < 0.05) to the target with the velocity ramp than without it. Using a physical prosthesis, subjects stacked a greater average number of 1 cubes (p < 0.05) in three minutes with the velocity ramp than without it (76% more blocks for non-amputees; 89% more blocks for amputees). Real-time control using the velocity ramp also showed significant performance improvements above using majority vote. Eighty-three percent of subjects preferred to control the prosthesis using the velocity ramp. These results suggest that using a decision-based velocity ramp with pattern recognition may improve user performance. Since the velocity ramp is a post-processing step, it has the potential to be used with a variety of classifiers for many applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 5×
“Feature extraction involving time-domain [5], [6], frequency-domain [7], or timefrequency feature sets [8] is an important step that significantly influences classifier performance [9].”
BackgroundMethodInfluentialA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“Feature extraction involving time-domain [5], [6], frequency-domain [7], or timefrequency feature sets [8] is an important step that significantly influences classifier performance [9].”
BackgroundKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 2×
“When provided with a good feature set, various classifiers such as linear discriminate analysis (LDA) [2], [9], Bayesian statistical methods [10], [11], artificial neural networks [4], [5], [12], and fuzzy logic [13], [14] have demonstrated offline accuracies ranging from 92% to 98%.”
BackgroundMethod
Cited by
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Self-citationA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Hargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Self-citationSix‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Betthauser, J. L., Krall, J. T., Bannowsky, S. G., Levay, G., Kaliki, R. R., Fifer, M. S., & Thakor, N. V. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2943309 · Cited by 73
Lukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
Sensitivity to temporal parameters of intraneural tactile sensory feedback
Valle, G., Strauss, I., D’Anna, E., Granata, G., Di Iorio, R., Stieglitz, T., Rossini, P. M., Raspopovic, S., Petrini, F. M., & Micera, S. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00737-8 · Cited by 20
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
Self-citation
Metadata
- Authors
- Simon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-08
- Volume
- 58
- Issue
- 8
- Pages
- 2360-2368
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2150092650
- Cited by
- 120
- References
- 9
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.