CoChat

Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System

Shao, Dangdang, Liu, Chenbin, Tsow, Francis, Yang, Yuting, Du, Zijian, Iriya, Rafael, Yu, Hui, Tao, Nongjian · 2016 · IEEE Transactions on Biomedical Engineering
Cited by 150

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We present a noncontact method to monitor blood oxygen saturation (SpO2). The method uses a CMOS camera with a trigger control to allow recording of photoplethysmography (PPG) signals alternatively at two particular wavelengths, and determines the SpO2 from the measured ratios of the pulsatile to the nonpulsatile components of the PPG signals at these wavelengths. The signal-to-noise ratio (SNR) of the SpO2 value depends on the choice of the wavelengths. We found that the combination of orange (λ = 611 nm) and near infrared (λ = 880 nm) provides the best SNR for the noncontact video-based detection method. This combination is different from that used in traditional contact-based SpO 2 measurement since the PPG signal strengths and camera quantum efficiencies at these wavelengths are more amenable to SpO2 measurement using a noncontact method. We also conducted a small pilot study to validate the noncontact method over an SpO2 range of 83%-98%. This study results are consistent with those measured using a reference contact SpO2 device ( r = 0.936, ). The presented method is particularly suitable for tracking one's health and wellness at home under free-living conditions, and for those who cannot use traditional contact-based PPG devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2015.2481896

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 150

Metadata

Authors
Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Yu, H., & Tao, N.
Venue
IEEE Transactions on Biomedical Engineering
Published
2016-06
Volume
63
Issue
6
Pages
1091-1098
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2398151908
Cited by
150
References
3
FWCI
3.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System. https://app.cochat.ai/papers/10.1109/tbme.2015.2481896
The paper
Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Yu, H., & Tao, N. (2016). Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2015.2481896

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.