Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 387

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters

Open access
Pimentel, Marco A. F., Johnson, Alistair E. W., Charlton, Peter H., Birrenkott, Drew, Watkinson, Peter J., Tarassenko, Lionel, Clifton, David A.·2017·IEEE Transactions on Biomedical Engineering

Abstract

GOAL: Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent "validation" datasets. The lack of robustness of existing methods directly results in a lack of penetration of such systems into clinical practice. The present work proposes an alternative method to improve the robustness of the estimation of RR from the PPG. METHODS: The proposed algorithm is based on the use of multiple autoregressive models of different orders for determining the dominant respiratory frequency in the three respiratory-induced variations (frequency, amplitude, and intensity) derived from the PPG. The algorithm was tested on two different datasets comprising 95 eight-minute PPG recordings (in total) acquired from both children and adults in different clinical settings, and its performance using two window sizes (32 and 64 seconds) was compared with that of existing methods in the literature. RESULTS: The proposed method achieved comparable accuracy to existing methods in the literature, with mean absolute errors (median, 25[Formula: see text]-75[Formula: see text] percentiles for a window size of 32 seconds) of 1.5 (0.3-3.3) and 4.0 (1.8-5.5) breaths per minute (for each dataset respectively), whilst providing RR estimates for a greater proportion of windows (over 90% of the input data are kept). CONCLUSION: Increased robustness of RR estimation by the proposed method was demonstrated. SIGNIFICANCE: This work demonstrates that the use of large publicly available datasets is essential for improving the robustness of wearable-monitoring algorithms for use in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2016.2613124

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 387

Metadata

Authors
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2017-08
Volume
64
Issue
8
Pages
1914-1923
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2552408385
Cited by
387
References
41
FWCI
4.26
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.