The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Open accessAbstract
GOAL: Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent "validation" datasets. The lack of robustness of existing methods directly results in a lack of penetration of such systems into clinical practice. The present work proposes an alternative method to improve the robustness of the estimation of RR from the PPG. METHODS: The proposed algorithm is based on the use of multiple autoregressive models of different orders for determining the dominant respiratory frequency in the three respiratory-induced variations (frequency, amplitude, and intensity) derived from the PPG. The algorithm was tested on two different datasets comprising 95 eight-minute PPG recordings (in total) acquired from both children and adults in different clinical settings, and its performance using two window sizes (32 and 64 seconds) was compared with that of existing methods in the literature. RESULTS: The proposed method achieved comparable accuracy to existing methods in the literature, with mean absolute errors (median, 25[Formula: see text]-75[Formula: see text] percentiles for a window size of 32 seconds) of 1.5 (0.3-3.3) and 4.0 (1.8-5.5) breaths per minute (for each dataset respectively), whilst providing RR estimates for a greater proportion of windows (over 90% of the input data are kept). CONCLUSION: Increased robustness of RR estimation by the proposed method was demonstrated. SIGNIFICANCE: This work demonstrates that the use of large publicly available datasets is essential for improving the robustness of wearable-monitoring algorithms for use in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Smith, G. B., Prytherch, D. R., Meredith, P., Schmidt, P. E., & Featherstone, P. I. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2012.12.016 · Cited by 1,077
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
ViEWS—Towards a national early warning score for detecting adult inpatient deterioration
Prytherch, D. R., Smith, G. B., Schmidt, P. E., & Featherstone, P. I. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.04.014 · Cited by 535
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246160 · Cited by 485
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
Self-citationOrphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Self-citationCharlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Self-citationReview and performance evaluation of aggregate weighted ‘track and trigger’ systems
Smith, G. B., Prytherch, D. R., Schmidt, P. E., & Featherstone, P. I. (2008) · Resuscitation · doi:10.1016/j.resuscitation.2007.12.004 · Cited by 337
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in Cardiology, 2003 · doi:10.1109/cic.2003.1291140 · Cited by 320
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Self-citationBonett, D. G., & Price, R. M. (2002) · Psychological Methods · doi:10.1037//1082-989x.7.3.370 · Cited by 209
Clifton, L., Clifton, D. A., Pimentel, M. A. F., Watkinson, P. J., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2293059 · Cited by 199
Self-citationOn an automatic delineator for arterial blood pressure waveforms
Li, B. N., Dong, M. C., & Vai, M. I. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.002 · Cited by 166
Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique
Nilsson, L. M., Johansson, A., & Kálmán, S. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011424732717 · Cited by 157
Deriving respiration from photoplethysmographic pulse width
Lázaro, J. M., Gil, E., Bailón, R., Mincholé, A., & Laguna, P. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0954-0 · Cited by 137
Wireless Technology in Disease Management and Medicine
Clifford, G. D., & Clifton, D. A. (2011) · Annual Review of Medicine · doi:10.1146/annurev-med-051210-114650 · Cited by 136
Self-citationCentile-based early warning scores derived from statistical distributions of vital signs
Tarassenko, L., Clifton, D. A., Pinsky, M. R., Hravnak, M., Woods, J. R., & Watkinson, P. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.03.006 · Cited by 133
Self-citationData Fusion for Improved Respiration Rate Estimation
Nemati, S., Malhotra, A., & Clifford, G. D. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2010/926305 · Cited by 117
Garde, A., Karlen, W., Ansermino, J. M., & Dumont, G. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086427 · Cited by 114
CapnoBase: Signal database and tools to collect, share and annotate respiratory signals
Karlen, W., Turner, M., Cooke, E., Dumont, G. A., & Ansermino, J. M. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000087887 · Cited by 114
Data fusion for estimating respiratory rate from a single-lead ECG
Orphanidou, C., Fleming, S., Shah, S. A., & Tarassenko, L. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.06.001 · Cited by 103
Self-citationStandard pulse oximeters can be used to monitor respiratory rate
Leonard, P. A., Beattie, T. F., Addison, P. S., & Watson, J. N. (2003) · Emergency Medicine Journal · doi:10.1136/emj.20.6.524 · Cited by 101
Tarassenko, S. G. F. L. (2007) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1080903 · Cited by 100
Addison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9332-y · Cited by 97
Adaptive pulse segmentation and artifact detection in photoplethysmography for mobile applications
Karlen, W., Ansermino, J. M., & Dumont, G. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346628 · Cited by 94
Shelley, K. H., Alian, A. A., Stout, R. G., & Silverman, D. G. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9010-7 · Cited by 86
Nilsson, L. M., Johansson, A., & Kálmán, S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00721.x · Cited by 78
Tutorial on Univariate Autoregressive Spectral Analysis
Takalo, R., Hytti, H., & Ihalainen, H. (2005) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-7089-x · Cited by 76
An Algorithm for the Detection of Individual Breaths from the Pulse Oximeter Waveform
Leonard, P. A., Grubb, N. R., Addison, P. S., Clifton, D. A., & Watson, J. N. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-2697-z · Cited by 70
Self-citationÁlvarez, C., Clark, C. A., Zhang, S., Halm, E. A., Shannon, J. J., Girod, C. E., Cooper, L., & Amarasingham, R. (2013) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-13-28 · Cited by 66
Probabilistic Estimation of Respiratory Rate from Wearable Sensors
Pimentel, M. A. F., Charlton, P. H., & Clifton, D. A. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_10 · Cited by 59
Self-citationSympathetically induced spontaneous fluctuations of the photoplethysmographic signal
Khanoka, B., Slovik, Y., Landau, D., & Nitzan, M. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351014 · Cited by 45
Respiratory rate estimation during triage of children in hospitals
Shah, S. A., Fleming, S., Thompson, M., & Tarassenko, L. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1105316 · Cited by 44
Self-citationPimentel, M. A. F., Santos, M., Springer, D., & Clifford, G. D. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/8/1717 · Cited by 44
Self-citationLarsen, P., Harty, M., Thiruchelvam, M., & Galletly, D. C. (1997) · International journal of clinical monitoring and computing · doi:10.1007/bf03356582 · Cited by 38
Semiconductor wireless technology for chronic disease management
Tarassenko, L., & Clifton, D. A. (2011) · Electronics Letters · doi:10.1049/el.2011.2679 · Cited by 18
Self-citationProbabilistic estimation of respiratory rate using Gaussian processes
Pimentel, M. A. F., Clifton, D. A., Clifton, L., & Tarassenko, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610147 · Cited by 16
Self-citationHardinge, F. M., Rutter, H., Velardo, C., Toms, C., Williams, V., Tarassenko, L., Farmer, A. A., & Team Edgecopd. (2014) · American Journal of Respiratory and Critical Care Medicine · Cited by 4
Self-citation
Cited by
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Self-citationGenerative Adversarial Networks in Time Series: A Systematic Literature Review
Brophy, E., Wang, Z., She, Q., & Ward, T. (2023) · ACM Computing Surveys · doi:10.1145/3559540 · Cited by 337
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Self-citationHeart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
Metadata
- Authors
- Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-08
- Volume
- 64
- Issue
- 8
- Pages
- 1914-1923
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2552408385
- Cited by
- 387
- References
- 41
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.