The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Abstract
OBJECTIVE: We present a review of wireless medical devices that are placed inside the human body to realize many and different sensing and/or stimulating functionalities. METHODS: A critical literature review analysis is conducted focusing on three types of in-body medical devices, i.e., 1) devices that are implanted inside the human body (implantables), 2) devices that are ingested like regular pills (ingestibles), and 3) devices that are injected into the human body via needles (injectables). Design considerations, current status, and future directions related to the aforementioned in-body devices are discussed. RESULTS: A number of design challenges are associated with in-body devices, including selection of operation frequency, antenna design, powering, and biocompatibility. Nevertheless, in-body devices are opening up new opportunities for medical prevention, prognosis, and treatment that quickly outweigh any design challenges and/or concerns on their invasive nature. CONCLUSION: In-body devices are already in use for several medical applications, ranging from pacemakers and capsule endoscopes to injectable microstimulators. As technology continues to evolve, in-body devices are promising several new and hitherto unexplored opportunities in the healthcare. SIGNIFICANCE: Unobtrusive in-body devices are envisioned to collect a multitude of physiological data from the early years of each individual. This big-data approach aims to enable a shift from symptom-based medicine to a proactive healthcare model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Regularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045
A Leadless Intracardiac Transcatheter Pacing System
Reynolds, D., Duray, G. Z., Omar, R., Soejima, K., Neuzil, P., Zhang, S., Narasimhan, C., Steinwender, C., Brugada, J., Lloyd, M., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1511643 · Cited by 933
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Kiourti, A., & Nikita, K. S. (2012) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2012.6293992 · Cited by 482
Self-citationRecent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.
Shabalovskaya, S. A. (2002) · PubMed · Cited by 429
Powering pacemakers from heartbeat vibrations using linear and nonlinear energy harvesters
Amin Karami, M., & Inman, D. J. (2012) · Applied Physics Letters · doi:10.1063/1.3679102 · Cited by 390
Kiourti, A., & Nikita, K. S. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2201078 · Cited by 337
Self-citationTowards glucose biofuel cells implanted in human body for powering artificial organs: Review
Cosnier, S., Le Goff, A., & Holzinger, M. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.09.021 · Cited by 291
Huang, F.-J., Lee, C.-M., Chang, C.-L., Chen, L.-K., Yo, T.-C., & Luo, C.-H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2152317 · Cited by 268
Power harvesting and telemetry in CMOS for implanted devices
Sauer, C., Stanacevic, M., Cauwenberghs, G., & Thakor, N. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.858183 · Cited by 249
Ultrasonic transcutaneous energy transfer for powering implanted devices
Ozeri, S., & Shmilovitz, D. (2010) · Ultrasonics · doi:10.1016/j.ultras.2009.11.004 · Cited by 240
An Ingestible Sensor for Measuring Medication Adherence
Hafezi, H., Robertson, T. L., Moon, G. D., Au-Yeung, K.-Y., Zdeblick, M. J., & Savage, G. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2341272 · Cited by 226
Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
Chow, E. Y., Chlebowski, A. L., Chakraborty, S., Chappell, W. J., & Irazoqui, P. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041058 · Cited by 222
A Wireless Power Interface for Rechargeable Battery Operated Medical Implants
Li, P., & Bashirullah, R. (2007) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2007.901613 · Cited by 220
Kiourti, A., Psathas, K. A., & Nikita, K. S. (2014) · Bioelectromagnetics · doi:10.1002/bem.21813 · Cited by 209
Self-citationChronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Adamson, P. B., Abraham, W. T., Aaron, M., Aranda, J. M., Bourge, R. C., Smith, A., Stevenson, L. W., Bauman, J. G., & Yadav, J. S. (2011) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2010.08.002 · Cited by 188
Weiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Wireless Neurosensor for Full-Spectrum Electrophysiology Recordings during Free Behavior
Yin, M., Borton, D. A., Komar, J., Agha, N., Lu, Y., Li, H., Laurens, J., Lang, Y., Li, Q., Bull, C., et al. (2014) · Neuron · doi:10.1016/j.neuron.2014.11.010 · Cited by 175
Cadei, A., Dionisi, A., Sardini, E., & Serpelloni, M. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/012003 · Cited by 158
Development and Implantation of a Minimally Invasive Wireless Subretinal Neurostimulator
Shire, D. B., Kelly, S. K., Chen, J., Doyle, P., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Mendoza, O., Theogarajan, L. S., Wyatt, J. L., et al. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2021401 · Cited by 156
Easy-to-Swallow Wireless Telemetry
Yuce, M. R., & Dissanayake, T. (2012) · IEEE Microwave Magazine · doi:10.1109/mmm.2012.2205833 · Cited by 144
Warty, R., Tofighi, M.-R., Kawoos, U., & Rosen, A. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2004254 · Cited by 142
Spherical, rolling magnet generators for passive energy harvesting from human motion
Bowers, B. J., & Arnold, D. P. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/9/094008 · Cited by 131
Injectable 3-D Fabrication of Medical Electronics at the Target Biological Tissues
Jin, C., Zhang, J., Li, X., Yang, X., Li, J., & Liu, J. (2013) · Scientific Reports · doi:10.1038/srep03442 · Cited by 126
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Ellozy, S. H., Carroccio, A., Lookstein, R., Minor, M. E., Sheahan, C. M., Juta, J., Cha, A., Valenzuela, R. G., Addis, M. D., Jacobs, T. S., et al. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.06.027 · Cited by 109
Handbook of Biomedical Telemetry
Nikita, K. S. (2014) · Wiley eBooks · doi:10.1002/9781118893715 · Cited by 106
Self-citationGroen, J., Amiel, C., & Bosch, J. L. H. R. (2005) · Neurourology and Urodynamics · doi:10.1002/nau.20131 · Cited by 103
In Vivo Verification of Implantable Antennas Using Rats as Model Animals
Karacolak, T., Cooper, R., Butler, J. R., Fisher, S., & Topsakal, E. (2010) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2010.2048693 · Cited by 102
Dual-Band Implantable Antenna With Open-End Slots on Ground
Xu, L., Guo, Y., & Wu, W. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2012.2237010 · Cited by 101
A Broadband Flexible Implantable Loop Antenna With Complementary Split Ring Resonators
Alrawashdeh, R., Huang, Y., Kod, M., & Sajak, A. A. B. (2015) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2015.2403952 · Cited by 94
Capsule endoscopy: Present status and future expectation
Goenka, M. K. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i29.10024 · Cited by 93
Miniaturized Dual-Band Antenna for Implantable Wireless Communications
Xu, L.-J., Guo, Y.-X., & Wu, W. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2329937 · Cited by 87
Biological Channel Modeling and Implantable UWB Antenna Design for Neural Recording Systems
Bahrami, H., Mirbozorgi, S. A., Rusch, L. A., & Gosselin, B. J. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2339836 · Cited by 87
Miniature Implantable Antennas for Biomedical Telemetry: From Simulation to Realization
Kiourti, A., Costa, J. R., Fernandes, C. A., Santiago, A. G., & Nikita, K. S. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2202659 · Cited by 86
Self-citationMiniature Microwave Biosensors: Noninvasive Applications
Guarin, G., Hofmann, M., Nehring, J., Weigel, R., Fischer, G., & Kissinger, D. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394024 · Cited by 86
Wireless Medical Telemetry Characterization for Ingestible Capsule Antenna Designs
Rajagopalan, H., & Rahmat‐Samii, Y. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2238502 · Cited by 81
Continuous in vivo blood pressure measurements using a fully implantable wireless SAW sensor
Murphy, O. H., Bahmanyar, M. R., Borghi, A., McLeod, C., Navaratnarajah, M., Yacoub, M. H., & Toumazou, C. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9759-7 · Cited by 77
A Wireless Fully Passive Neural Recording Device for Unobtrusive Neuropotential Monitoring
Kiourti, A., Lee, C. W. L., Chae, J., & Volakis, J. L. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2458583 · Cited by 77
Self-citationIn-Vitro and In-Vivo Trans-Scalp Evaluation of an Intracranial Pressure Implant at 2.4 GHz
Kawoos, U., Tofighi, M.-R., Warty, R., Kralick, F., & Rosen, A. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2004253 · Cited by 76
Body Electric: Wireless Power Transfer for Implant Applications
Rao, S., & Chiao, J. ‐. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377586 · Cited by 75
Intestinal Gas Capsules: A Proof-of-Concept Demonstration
Kalantar‐Zadeh, K., Yao, C. K., Berean, K. J., Ha, N., Ou, J. Z., Ward, S. A., Pillai, N., Hill, J., Cottrell, J. J., Dunshea, F. R., et al. (2015) · Gastroenterology · doi:10.1053/j.gastro.2015.07.072 · Cited by 74
Home Telemonitoring of Vital Signs—Technical Challenges and Future Directions
Celler, B. G., & Sparks, R. S. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2351413 · Cited by 74
A Hybrid Patch/Slot Implantable Antenna for Biotelemetry Devices
Liu, C.-R., Guo, Y.-X., & Xiao, S. (2012) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2237879 · Cited by 74
Design of a 2Mbps FSK near-field transmitter for wireless capsule endoscopy
Thoné, J., Radiom, S., Turgis, D., Carta, R., Gielen, G. E., & Puers, R. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.11.027 · Cited by 67
First clinical experience with BION implants for therapeutic electrical stimulation
Salter, A.-C. D., Bagg, S. D., Creasy, J. L., Romano, C., Romano, D., Richmond, F. J. R., & Loeb, G. E. (2004) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2004.04005.x · Cited by 66
BION microstimulators: A case study in the engineering of an electronic implantable medical device
Kane, M. J., Breen, P. P., Quondamatteo, F., & OLaighin, G. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.08.010 · Cited by 65
Social Implications of Technology: The Past, the Present, and the Future
Stephan, K. D., Michael, K., Michael, M. G., Jacob, L., & Anesta, E. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2189919 · Cited by 63
Schwerdt, H. N., Xu, W., Shekhar, S., Abbaspour-Tamijani, A., Towe, B. C., Miranda, F. A., & Chae, J. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2162487 · Cited by 61
A High-Sensitivity Fully Passive Neurosensing System for Wireless Brain Signal Monitoring
Lee, C. W. L., Kiourti, A., Chae, J., & Volakis, J. L. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2421491 · Cited by 61
Self-citationGrand Challenges in Interfacing Engineering With Life Sciences and Medicine
He, B., Baird, R. A., Butera, R. J., Datta, A. A., George, S. C., Hecht, B., Hero, A. O., Lazzi, G., Lee, R. C., Liang, J., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244886 · Cited by 55
The Feasible FES System: Battery Powered BION Stimulator
Schulman, J. H. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922588 · Cited by 52
Kawoos, U., Xu, M., Tofighi, M.-R., & Rosen, A. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377585 · Cited by 37
Subcutaneous blood pressure monitoring with an implantable optical sensor
Theodor, M., Ruh, D., Fiala, J., Förster, K., Heilmann, C., Manoli, Y., Beyersdorf, F., Zappe, H. P., & Seifert, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9768-6 · Cited by 36
The injectable neurostimulator: an emerging therapeutic device
Li, X., Serdijn, W. A., Zheng, W., Tian, Y., & Zhang, B. (2015) · Trends in biotechnology · doi:10.1016/j.tibtech.2015.04.001 · Cited by 35
Toward an Injectable Continuous Osmotic Glucose Sensor
Johannessen, E. A., Krushinitskaya, O., Sokolov, A., Hafliger, P. D., Hoogerwerf, A. C., Hinderling, C., Kautio, K. T., Lenkkeri, J., Strömmer, E., Kondratyev, V., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400417 · Cited by 33
The use of permanent pacemakers in the detection of cardiac arrhythmias
Plummer, C., Henderson, S., Gardener, L., & McComb, J. M. (2001) · EP Europace · doi:10.1053/eupc.2001.0178 · Cited by 21
Measurement of Wireless Link for Brain–Machine Interface Systems Using Human-Head Equivalent Liquid
Moradi, E., Björninen, T., Sydanheimo, L. T., Carmena, J. M., Rabaey, J. M., & Ukkonen, L. (2013) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2283737 · Cited by 19
Dynamic study of wireless intracranial pressure monitoring of rotational head injury in swine model
Meng, X., Browne, K., Huang, S.-M., Cullen, D. K., Tofighi, M., & Rosen, A. (2012) · Electronics Letters · doi:10.1049/el.2012.0281 · Cited by 15
A microwave powered injectable neural stimulator
Towe, B. C., Larson, P. J., & Gulick, D. W. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347117 · Cited by 14
PRELIMINARY EXPERIENCE WITH IMPLANTED MICROSTIMULATORS FOR MANAGEMENT OF POST-STROKE IMPAIRMENTS
Baker, L. L., Eberly, V. J., Rakoski, D., Waters, R. L., Eberly, V. J., Palmer, E. S., RICHMOND, F. J. R., & Loeb, G. E. (2006) · Neurology Report · doi:10.1097/01.npt.0000281299.48292.03 · Cited by 9
Cited by
The Internet of Things, Fog and Cloud continuum: Integration and challenges
Bittencourt, L., Immich, R., Sakellariou, R., Fonseca, N., Madeira, E., Curado, M., Villas, L., DaSilva, L., Lee, C., & Rana, O. (2018) · Internet of Things · doi:10.1016/j.iot.2018.09.005 · Cited by 370
An Overview of Patient’s Health Status Monitoring System Based on Internet of Things (IoT)
Kadhim, K. T., Alsahlany, A. M., Wadi, S. M., & Kadhum, H. T. (2020) · Wireless Personal Communications · doi:10.1007/s11277-020-07474-0 · Cited by 267
Metadata
- Authors
- Kiourti, A., & Nikita, K. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-07
- Volume
- 64
- Issue
- 7
- Pages
- 1422-1430
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2588679294
- Cited by
- 278
- References
- 64
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.