Robust Real-Time Musculoskeletal Modeling Driven by Electromyograms
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Current clinical biomechanics involves lengthy data acquisition and time-consuming offline analyses with biomechanical models not operating in real-time for man-machine interfacing. We developed a method that enables online analysis of neuromusculoskeletal function in vivo in the intact human. METHODS: We used electromyography (EMG)-driven musculoskeletal modeling to simulate all transformations from muscle excitation onset (EMGs) to mechanical moment production around multiple lower-limb degrees of freedom (DOFs). We developed a calibration algorithm that enables adjusting musculoskeletal model parameters specifically to an individual's anthropometry and force-generating capacity. We incorporated the modeling paradigm into a computationally efficient, generic framework that can be interfaced in real-time with any movement data collection system. RESULTS: The framework demonstrated the ability of computing forces in 13 lower-limb muscle-tendon units and resulting moments about three joint DOFs simultaneously in real-time. Remarkably, it was capable of extrapolating beyond calibration conditions, i.e., predicting accurate joint moments during six unseen tasks and one unseen DOF. CONCLUSION: The proposed framework can dramatically reduce evaluation latency in current clinical biomechanics and open up new avenues for establishing prompt and personalized treatments, as well as for establishing natural interfaces between patients and rehabilitation systems. SIGNIFICANCE: The integration of EMG with numerical modeling will enable simulating realistic neuromuscular strategies in conditions including muscular/orthopedic deficit, which could not be robustly simulated via pure modeling formulations. This will enable translation to clinical settings and development of healthcare technologies including real-time bio-feedback of internal mechanical forces and direct patient-machine interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Optimization of Statistical Functions with Simulated Annealing
Goffe, W. L., Ferrier, G. D., & Rogers, J. (1994) · Journal of Econometrics · doi:10.1016/0304-4076(94)90038-8 · Cited by 1,610 · cited 1×
“Parameters are varied using a simulated annealing procedure [34] until the discrepancy between experimental and predicted joint moments is minimized over a range of calibration trials (Section III).”
MethodA real-time system for biomechanical analysis of human movement and muscle function
van den Bogert, A. J., Geijtenbeek, T., Even-Zohar, O., Steenbrink, F., & Hardin, E. C. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-013-1076-z · Cited by 392 · cited 1×
“Recent studies proposed online solutions, facilitating translation to clinical scenarios [8], [9].”
BackgroundLower-Limb Kinematics of Single-Leg Squat Performance in Young Adults
Horan, S. A., Watson, S. L., Carty, C. P., Sartori, M., & Weeks, B. K. (2014) · Physiotherapy Canada · doi:10.3138/ptc.2013-09 · Cited by 43 · cited 1×
“IK-generated angles reflect literature values across forward gait [35], backward gait [3], and squat tasks [36].”
BackgroundSelf-citation
Research works printed but not linked: 41
- 10.1007/s00221-004-1973-3 · doi:10.1007/s00221-004-1973-3
- pope, 2012, Comparison of Scaled vs Ultrasound Based Musculoskeletal Models on Knee Muscle Moments During Single-Leg Squatting
- 10.1016/j.jbiomech.2008.03.008 · doi:10.1016/j.jbiomech.2008.03.008
- 10.1109/TBME.2012.2208746 · DOI
- 10.1016/S0021-9290(03)00152-0 · DOI
- b?a?kiewicz, 2013, Muscle force distribution during forward and backward locomotion, Acta Bioeng Biomech, 15, 3
- 10.1016/j.jbiomech.2008.07.031 · DOI · Paper page
- 10.1152/jn.1998.80.4.1868 · DOI
- 10.1016/0021-9290(91)90375-W · DOI · Paper page
- 10.1016/S0966-6362(98)00007-1 · doi:10.1016/s0966-6362(98)00007-1
- 10.1016/S0021-9290(03)00010-1 · DOI · Paper page
- 10.1186/1475-925X-13-37 · DOI
- 10.1016/j.compbiomed.2009.09.002 · DOI · Paper page
- 10.1371/journal.pone.0052618 · DOI · Paper page
- 10.3389/fncom.2013.00079 · DOI
- 10.1115/1.4023255 · doi:10.1115/1.4023255
- 10.1152/jn.00989.2014 · DOI
- 10.1152/jn.2002.87.6.2808 · DOI
- 10.1016/j.gaitpost.2006.09.074 · DOI
- 10.1109/10.102791 · DOI · Paper page
- 10.1016/j.jbiomech.2013.09.005 · doi:10.1016/j.jbiomech.2013.09.005
- 10.1016/j.jbiomech.2011.10.040 · DOI
- 10.1016/j.jbiomech.2013.06.001 · DOI
- 10.1016/j.simpat.2006.09.001 · DOI · Paper page
- 10.1016/j.jbiomech.2008.09.035 · DOI
- 10.1109/TBME.2007.901024 · DOI · Paper page
- 10.1016/j.pbiomolbio.2010.09.006 · DOI
- 10.1016/0021-9290(90)90349-8 · DOI · Paper page
- 10.1016/0021-9290(81)90035-X · DOI · Paper page
- 10.1146/annurev.bioeng.3.1.245 · DOI · Paper page
- 10.1115/1.4026428 · DOI
- 10.1007/s11044-011-9285-4 · DOI
- 10.1016/S0010-4825(01)00024-5 · DOI
- 10.1109/TBME.2016.2538296 · DOI · Paper page
- 10.1109/TRO.2008.926860 · DOI · Paper page
- 10.1249/01.mss.0000176684.24008.6f · DOI · Paper page
- 10.1109/TBME.2006.880883 · DOI · Paper page
- 10.1002/wsbm.1368 · DOI
- 10.1016/j.jbiomech.2015.09.021 · DOI · Paper page
- 10.1186/s12984-016-0170-5 · doi:10.1186/s12984-016-0170-5
- 10.1109/TBME.2008.2005946 · DOI · Paper page
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationSartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
“Based on our recent work [14] we developed two software plug-in modules that enabled direct TCP/ IP connection between the real-time modeling framework and external devices.”
BackgroundMethodSelf-citationMolinaro, D. D., Kang, I., Camargo, J., Gombolay, M. C., & Young, A. J. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3144025 · Cited by 90
Liu, X.-Y., Li, G., Zhou, X.-H., Liang, X., & Hou, Z.-G. (2025) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2025.3565754 · Cited by 36
“The model-based methods involve the kinematics model [19], the dynamic model [17], and the musculoskeletal model [18].”
Molinaro, D. D., Park, E. O., & Young, A. J. (2023) · 2023 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra48891.2023.10161286 · Cited by 14
Metadata
- Authors
- Durandau, G., Farina, D., & Sartori, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-03
- Volume
- 65
- Issue
- 3
- Pages
- 556-564
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2612974132
- Cited by
- 157
- References
- 3
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- ERC Advanced under Grant DEMOVE (267888)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust Real-Time Musculoskeletal Modeling Driven by Electromyograms. https://app.cochat.ai/papers/10.1109/tbme.2017.2704085
- The paper
- Durandau, G., Farina, D., & Sartori, M. (2018). Robust Real-Time Musculoskeletal Modeling Driven by Electromyograms. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2017.2704085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.