On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDA
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In this paper, the motor current/voltage signature analysis and linear discriminant analysis (LDA) are evaluated with respect to the accuracy to detect the status of permanent magnet synchronous machines (PMSMs) whether it is healthy or faulted, determine the type of that fault, and estimate the severity in the case of static eccentricity or turn-to-turn short-circuit fault. Three types of faults are discussed: static eccentricity, turn-to-turn short circuit, and partial demagnetization fault. Two-dimensional finite element analysis (FEA) is used to model and simulate the machine under healthy and faulted conditions. Fast Fourier transform is applied to the phase voltage or current signals to obtain the frequency spectrum. A combination of the amplitude of the harmonics of the stator voltage or current signals are used as detailed features for the classifier for fault detection. LDA is chosen as a classification method for both detecting the fault and estimating its severity. Two different winding types of PMSMs are tested: a concentrated and a distributed winding machine. To validate the simulation results, experiments at different operational points are carried out and the results are compared with the sFEA.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, fault detection accuracy based on current signal analysis is significantly influenced by inverter output harmonics, load fluctuations and controller settings [87], [88].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [88]
In the citing paper
“The usage of FFT analysis requires a compromise between the precision of the assessment of damage symptoms and the minimum computational effort [86], [88].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [88]
Citations
Cites
Martinez, A. M., & Kak, A. C. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.908974 · Cited by 3,249
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386
Nandi, S., Ahmed, S., & Toliyat, H. A. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937205 · Cited by 340
Classification, estimation, and pattern recognition
Young, T. Y., & Calvert, T. W. (1974) · International Linear Collider · Cited by 332
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Nandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Ebrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Thomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Detection of Rotor Faults in Brushless DC Motors Operating Under Nonstationary Conditions
Rajagopalan, S., Aller, J. M., Restrepo, J. A., Habetler, T. G., & Harley, R. G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882613 · Cited by 143
Zhu, Z. Q., Wu, L., & Jamil, M. L. M. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2308363 · Cited by 93
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48 · cited 2×
“It was proven in [17] that for a controller with higher bandwidth, the fault information produced in the current will also be contained in the voltage signal.”
BackgroundMethodHaddad, R. Z., & Strangas, E. G. (2013) · 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645703 · Cited by 46 · cited 1×
“Here, we continue the work of [3].”
Self-citationRosero, J., Romeral, J. L., Cusido, J., Ortega, J. A., & Garcia, A. (2008) · 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2008.4522708 · Cited by 44 · cited 2×
“These methods can be categorized as: time domain methods, frequency analysis methods as in [1]–[5], and time scale analysis methods such as discrete or continuous wavelet transform (D/CWT) [6], [7].”
BackgroundMethodAnalysis of Eccentricity in Permanent-Magnet Tubular Machines
Cappelli, L., Coia, Y., Marignetti, F., & Zhu, Z. Q. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2271598 · Cited by 38
Outer race bearing fault detection in induction machines using stator current signals
Haddad, R. Z., Lopez, C. A., Pons-Llinares, J., Daviu, J. A. A., & Strangas, E. G. (2015) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281839 · Cited by 27
Self-citationRosero, J., Espinosa, A. G., Cusido, J., Ortega, J. A., & Romeral, L. (2008) · 2008 IEEE Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2008.4547070 · Cited by 25
Haddad, R. Z., & Strangas, E. G. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303702 · Cited by 20
Self-citationHarmouche, J., Delpha, C., & Diallo, D. (2014) · International Conference on Green Energy (ICGE) · doi:10.1109/icge.2014.6835419 · Cited by 17
Γεωργακόπουλος, Η., Mitronikas, E. D., Safacas, A. N., & Tsoumas, I. P. (2008) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2008.4591976 · Cited by 13
Xiao, Z., & Fang, H. (2011) · 2011 International Conference on Control, Automation and Systems Engineering (CASE) · doi:10.1109/iccase.2011.5997721 · Cited by 11
Modeling & analysis of weld short faults of bar-wound propulsion IPM machine part I: Turn short
Hao, L., Nawrocki, S., & Tang, X. (2011) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2011.6043056 · Cited by 9
Wavelet-LDA-neural network based short circuit occurrence detection in induction motor winding
Asfani, D. A., Syafaruddin, S., Purnomo, M. H., & Hiyama, T. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063644 · Cited by 6
Akilez Krishnamurthy, A., Belur, M. N., & Chakraborty, D. (2011) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2011.6161032 · Cited by 2
Research works printed but not linked: 2
- roux, 0, Rotor fault analysis of a permanent magnet synchronous machine, Proc 15th Int Conf Electr Mach
- rosero, 0, On-line condition monitoring technique for PMSM perated with eccentricity, Proc IEEE Int Symp Diag Electr Mach Power Electron Drives, 95
Cited by
A review on fault detection and diagnosis techniques: basics and beyond
Abid, A., Khan, M. T., & Iqbal, J. (2021) · Artificial Intelligence Review · doi:10.1007/s10462-020-09934-2 · Cited by 436
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The usage of FFT analysis requires a compromise between the precision of the assessment of damage symptoms and the minimum computational effort [86], [88].”
BackgroundMethodInfluentialMotor Fault Diagnostics Based on Current Signatures: A Review
Niu, G., Dong, X., & Chen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285999 · Cited by 269
Zafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Metadata
- Authors
- Haddad, R. Z., & Strangas, E. G.
- Affiliations
- Michigan State University (US)
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2016-09
- Volume
- 31
- Issue
- 3
- Pages
- 924-934
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2343408121
- Cited by
- 158
- References
- 27
- Citations by year
- 2026: 8 · 2025: 18 · 2024: 14 · 2023: 22 · 2022: 25 · 2021: 22 · 2020: 20 · 2019: 13 · 2018: 9 · 2017: 7
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Energy Conversion (publishedVersion)
- Funders
- National Science Foundation (ECCS1102316)
- Jordan University of Science and Technology (TEC-00317-2015)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, fault detection, fault classification, linear discriminant analysis, motor current signature analysis, static eccentricity, turn-to-turn short circuit, partial demagnetization, fault severity estimation, concentrated winding, distributed winding, harmonic characteristics, finite element analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.