Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper deals with the postfault current control strategies of a five-phase permanent-magnet (PM) motor. The analysis covers both the open circuit of one and two phases and the short circuit at the machine terminal of one phase. The proposed control guarantees safe drive operation after any fault occurrence. For the sake of generality, an analytical model has been used to investigate the properties of each postfault strategy. The results are general, and they apply to PM motor of any power rating. Simulations and experimental results validate the theoretical predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Five-Phase Permanent-Magnet Motor Drives
Parsa, L., & Toliyat, H. A. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.841021 · Cited by 462
Design considerations for fractional-slot winding configurations of synchronous machines
Bianchi, N., Bolognani, S., Pre, M. D., & Grezzani, G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876070 · Cited by 447
Self-citationJack, A. G., Mecrow, B. C., & Haylock, J. A. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.511646 · Cited by 368
Improved Reliability in Solid-State AC Drives by Means of Multiple Independent Phase Drive Units
Jahns, T. M. (1980) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1980.4503793 · Cited by 358
Jack, A. G., Mecrow, B. C., & Haylock, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530372 · Cited by 306
Use of the star of slots in designing fractional-slot single-layer synchronous motors
Bianchi, N., & Dai Pré, M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050284 · Cited by 263
Self-citationDesign and Testing of a Four-Phase Fault-Tolerant Permanent-Magnet Machine for an Engine Fuel Pump
Mecrow, B. C., Jack, A. G., Atkinson, D. J., Green, S. R., Atkinson, G. J., King, A., & Green, B. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832074 · Cited by 252
A Fault-Tolerant Control Architecture for Induction Motor Drives in Automotive Applications
Diallo, D., Benbouzid, M. E. H., & Makouf, A. (2004) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2004.833610 · Cited by 194
Optimal torque control of fault-tolerant permanent magnet brushless machines
Wang, J., Atallah, K., & Howe, D. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.816707 · Cited by 162
Operation of a fault tolerant PM drive for an aerospace fuel pump application
Haylock, J. A. (1997) · Eighth International Conference on Electrical Machines and Drives · doi:10.1049/cp:19971053 · Cited by 101
Cited by
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264
Baudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Dieterle, O., Greiner, T., & Heidrich, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835422 · Cited by 25
“Results for maximized torque are given in [13]–[16] for five-phase machines and in [11] for a dual three-phase machine.”
Background
Metadata
- Authors
- Bianchi, N., Bolognani, S., & Dai Pre, M.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2007
- Volume
- 43
- Issue
- 4
- Pages
- 960-970
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2104532649
- Cited by
- 276
- References
- 13
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.